01 — Reference run

A sizing result with its assumptions attached.

Conductor16 AWG1.5 mm²
Fuse1 Apositive run
Voltage drop0.1%9.8 ft one way
Design current0.2 A12 V system

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The Crimp engine applies its ordinary continuous-load headroom, voltage-drop budget, terminal clamp, and standard fuse ladder. The 9.8 ft one-way run is a stated reference, not a universal installation prescription.

02 — Catalog specification

The part the engine actually sees.

Continuous draw
0.2 A
Canvas footprint
185 × 105 px

Terminal map

TerminalPolarityDirectionRating
+12Vpositiveinput1 A
GNDgroundinput1 A
03 — Supporting parts

What belongs around it.

  • 19.7 ft total of 16 AWG (1.5 mm²) marine cable
  • Four 16 AWG cable lugs matched to the equipment studs
  • 1 A fuse and holder on the positive run
  • Heat-shrink, strain relief, and terminal boots sized to the cable

See what it changes in your system