01 — Reference run

A sizing result with its assumptions attached.

Conductor25 mm²4 AWG
Fuse100 Apositive run
Voltage drop2.8%3 m one way
Design current80 A12 V system

The Crimp engine applies its ordinary continuous-load headroom, voltage-drop budget, terminal clamp, and standard fuse ladder. The 3 m one-way run is a stated reference, not a universal installation prescription.

02 — Catalog specification

The part the engine actually sees.

Compatible systems
12 V / 24 V / 36 V / 48 V / 60 V
Rated output
80 A
Typical charge current
80 A
PV open-circuit limit
150 V
Canvas footprint
240 × 145 px

Terminal map

TerminalPolarityDirectionRating
PV +positiveinput90 A
PV −negativeinput90 A
BATT +positiveoutput80 A
BATT −negativeoutput80 A
03 — Supporting parts

What belongs around it.

  • 6 m total of 25 mm² (4 AWG) marine cable
  • Four 25 mm² cable lugs matched to the equipment studs
  • 100 A fuse and holder on the positive run
  • Heat-shrink, strain relief, and terminal boots sized to the cable