Crimp
Component folio · Monitoring · Victron

Victron SmartShunt 1000A

Model SmartShunt 1000A

1000 A/50 mV battery shunt with Bluetooth and a VE.Direct port, no display. Reads out through the VictronConnect app or a GX device; supports 6.5–70 V systems.

Open in Crimp →
Victron SmartShunt 1000A
Victron SmartShunt 1000A · 3 terminals
01 — Wiring diagram

How the SmartShunt 1000 is wired

Victron SmartShunt 1000A wiring diagram WIRING DIAGRAM Victron SmartShunt 1000A wiring diagram System bus Positive and negative rails SmartShunt 1000 Victron · SmartShunt 1000A BATT − LOAD − B+ sense crimp.studio Terminal map · no standalone feed to size
Victron SmartShunt 1000A wiring diagram, positive and negative connections between the system bus and the unit, plus LOAD −, B+ sense.

The run drawn here is the reference topology for this part. Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. Confirm your own run length, routing and terminations before ordering — open this part in the designer to size it against your actual system.

02 — Reference run

What size cable and fuse does the SmartShunt 1000 need?

There is no standalone feed to size here: this part either has no positive current-carrying terminal or declares no continuous draw or rated output of its own, so a lone cable number would really be its terminal rating. Its cables are sized by the circuits they serve — use the terminal map and the complete-system fit check.

03 — Catalog specification

Victron SmartShunt 1000A specifications and terminal map

Terminal map

TerminalPolarityDirectionRating
BATT −negativeinput1000 A
LOAD −negativeoutput1000 A
B+ sensesignalbidi1 A
04 — Supporting parts

What else you need to wire the SmartShunt 1000

  • Terminations matched to each catalog terminal
  • Strain relief and terminal protection for the installation
  • Connection hardware selected from the complete system topology

Start from this part

Open the canvas with the SmartShunt 1000 already placed, then wire the rest of the system around it. Nothing to install and no sign-up — the project is saved in this browser, and you can download the file whenever you want it.

Open the canvas →

05 — Method & provenance

What is known, assumed, and computed.

Catalog profile

The manufacturer, model, ratings and terminal map are maintained as planning data in Crimp's component catalog. Confirm the current manufacturer manual, exact revision and installed nameplate before ordering or wiring.

Engine reference

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The published conductor, fuse and voltage-drop result uses the visible reference length and current basis; it is not a universal installation prescription.

Read the complete methodology →
06 — Related components

Alternatives to the SmartShunt 1000

Browse all monitoring profiles →