Crimp
Component folio · Monitoring · Victron

Victron Venus GX

Model Venus GX

Compact GX system control & VRM gateway. Predecessor to Cerbo GX, still widely deployed.

Open in Crimp →
Victron Venus GX
Victron Venus GX · 2 terminals
01 — Wiring diagram

How the Venus GX is wired

Victron Venus GX wiring diagram WIRING DIAGRAM Victron Venus GX wiring diagram 12 V battery bank Supplies this load Venus GX Victron · Venus GX 1 A 16 AWG (1.5 mm²) → +12V 16 AWG (1.5 mm²) → GND 10 ft one way crimp.studio 0.2 A · 0.1% drop · ABYC E-11
Victron Venus GX wiring diagram, 16 AWG (1.5 mm²) positive feed protected by a 1 A fuse and a matching negative return between the 12 V battery bank and the unit.

The run drawn here is the 10 ft reference run sized below. Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. Confirm your own run length, routing and terminations before ordering — open this part in the designer to size it against your actual system.

02 — Reference run

What size cable and fuse does the Venus GX need?

Conductor16 AWG1.5 mm²
Fuse1 Apositive run
Voltage drop0.1%10 ft one way
Design current0.2 A12 V system

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The design current is the part's continuous draw. The Crimp engine applies its ordinary continuous-load headroom, voltage-drop budget, terminal clamp, and standard fuse ladder. The 10 ft one-way run is a stated reference, not a universal installation prescription.

03 — Catalog specification

Victron Venus GX specifications and terminal map

Continuous draw
0.2 A

Terminal map

TerminalPolarityDirectionRating
+12Vpositiveinput1 A
GNDgroundinput1 A
04 — Supporting parts

What else you need to wire the Venus GX

  • 20 ft total of 16 AWG (1.5 mm²) marine cable
  • Four 16 AWG cable lugs matched to the equipment studs
  • 1 A fuse and holder on the positive run
  • Heat-shrink, strain relief, and terminal boots sized to the cable

Start from this part

Open the canvas with the Venus GX already placed, then wire the rest of the system around it. Nothing to install and no sign-up — the project is saved in this browser, and you can download the file whenever you want it.

Open the canvas →

05 — Method & provenance

What is known, assumed, and computed.

Catalog profile

The manufacturer, model, ratings and terminal map are maintained as planning data in Crimp's component catalog. Confirm the current manufacturer manual, exact revision and installed nameplate before ordering or wiring.

Engine reference

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The published conductor, fuse and voltage-drop result uses the visible reference length and current basis; it is not a universal installation prescription.

Read the complete methodology →
06 — Related components

Alternatives to the Venus GX

Browse all monitoring profiles →