ITR040362042
Victron Isolation Transformer 3600W 115/230V connections
Review the Victron Isolation Transformer 3600W 115/230V catalog ratings, AC connection points and installation notes, then add the part to your Crimp diagram.
- Nominal voltage
- 230 V
Connection overview
Isolation 3600W connections.
See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.
Installation notes
Before you install.
Open a question for model-specific guidance and sources.
Verified against the manufacturer's documentation (rev. Isolation Transformer ITR040362042 manual; manually configured 3600W version), checked 2026-10-01. Manufacturer documentation →
Which isolation transformer is this?
This is ITR040362042, the manually configured 3600 W model, not the automatic-input variant. The manufacturer manual gives 115/230 V input, 120/240 V output, and 32 A / 16 A ratings respectively. The planner’s default is the 230 V, 16 A arrangement. The transformer changes voltage configuration, not frequency.
How are shore and vessel connected?
The primary INPUT L/N/PE and secondary OUTPUT L/N/PE are distinct. Power crosses magnetically; there is no conductive primary-to-secondary line or neutral path. Afloat, shore earth remains isolated from the vessel earth. Follow the manual’s secondary neutral-to-earth link so downstream protective devices have the intended fault path. This is different from removing the earth wire from a conventional shore connection.
What must be configured before energizing?
Installation pages 5–9 identify separate input and output jumper settings, the secondary neutral/earth link, enclosure grounding and cable glands. Check both voltage configurations against the actual shore supply and vessel distribution. Never move jumpers on an energized transformer. The special shore-to-vessel earth bridge is for the specified out-of-water maintenance/storage condition, not the normal afloat arrangement.
What should operation look like?
Soft start limits startup inrush; it does not replace feeder overcurrent protection or downstream leakage protection. Keep the IP21 enclosure dry and ventilated. The fan increases speed with temperature and thermal protection stops operation if it overheats. Verify output voltage before connecting sensitive loads, and investigate repeated thermal shutdown by checking load and cooling clearance.
Technical reference
Specifications and terminal map.
Check the model, ratings and connection points against your own unit before choosing installation hardware.
Catalog specification
Manually configured 3600W isolation transformer for 115/230V shore input and 120/240V output. Primary and secondary have no conductive connection; afloat shore earth and vessel earth remain isolated. Rating is 32A at 115V or 16A at 230V, with soft start and thermal shutdown.
- Nominal voltage
- 230 V
Terminal map
Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.
SHORE L
neutral · input
SHORE N
neutral · input
SHORE PE
ground · input
VESSEL L
neutral · output
VESSEL N
neutral · output
VESSEL PE
ground · output
Sources and sizing method
Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.
Connection overview. This diagram explains the connection arrangement; it does not calculate cable sizes or protection for the installation. Follow the manufacturer’s complete wiring and protection instructions.
Read how the sizing worksNext step
Plan your installation with Isolation 3600W.
Open the connection overview as a new project, or add this component to a diagram you already have.
Free for up to 10 equipment components, with no account needed. Cables, busbars and fuse hardware do not count toward the limit. Your drawing saves in this browser. File exports are included with Crimp Pro.