Victron MultiPlus-II 12/3000 2x120V
3000VA / 2400W inverter/charger, 120A charger, 50A transfer switch — wired for North American 120/240V split-phase (two 120V legs, L1 + L2). 12 V DC input/output. UL 458 listed.
Open in Crimp →
How the MultiPlus-II 2x120 is wired
The run drawn here is the 10 ft reference run sized below. Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. Confirm your own run length, routing and terminations before ordering — open this part in the designer to size it against your actual system.
What size cable and fuse does the MultiPlus-II 2x120 need?
Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The design current is the part's continuous draw. The Crimp engine applies its ordinary continuous-load headroom, voltage-drop budget, terminal clamp, and standard fuse ladder. The 10 ft one-way run is a stated reference, not a universal installation prescription.
Victron MultiPlus-II 12/3000 2x120V specifications and terminal map
- Compatible systems
- 12 V
- Rated power
- 2,400 W
- Continuous draw
- 215 A
- Rated output
- 120 A
- Surge current
- 500 A
Terminal map
| Terminal | Polarity | Direction | Rating |
|---|---|---|---|
| AC IN L1 | neutral | input | 50 A |
| AC IN L2 | neutral | input | 50 A |
| AC IN N | neutral | input | 50 A |
| DC + | positive | input | 400 A |
| DC − | negative | input | 400 A |
| AC OUT L1 | neutral | output | 30 A |
| AC OUT L2 | neutral | output | 30 A |
| AC OUT N | neutral | output | 30 A |
What else you need to wire the MultiPlus-II 2x120
- 20 ft total of 4/0 AWG (120 mm²) marine cable
- Four 4/0 AWG cable lugs matched to the equipment studs
- 350 A fuse and holder on the positive run
- Heat-shrink, strain relief, and terminal boots sized to the cable
Start from this part
Open the canvas with the MultiPlus-II 2x120 already placed, then wire the rest of the system around it. Nothing to install and no sign-up — the project is saved in this browser, and you can download the file whenever you want it.
What is known, assumed, and computed.
Catalog profile
The manufacturer, model, ratings and terminal map are maintained as planning data in Crimp's component catalog. Confirm the current manufacturer manual, exact revision and installed nameplate before ordering or wiring.
Engine reference
Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The published conductor, fuse and voltage-drop result uses the visible reference length and current basis; it is not a universal installation prescription.