Freedom XC PRO 3000 (818-3010)

Xantrex Freedom XC PRO 3000 120V wiring diagram

12V inverter/charger with 3000W continuous 120VAC output, 150A charging and a 50A transfer relay (40A continuous). The manual publishes 304A nominal DC input at full inverter load. Standard 818-3010 and marine variants have different installation hardware; this entry is the standard model.

Nominal voltage
12 V
Compatible systems
12 V
Rated power
3,000 W

Wiring diagram

How the Freedom XC PRO 3000 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Xantrex Freedom XC PRO 3000 120V wiring example with 3 components: House bank, High-current disconnect, Freedom XC PRO 3000. 3 cable connections. Crossings are not junctions.High-current disconnect B to Freedom XC PRO 3000 BATT +: 120 mm² · 350 A fuse, 1.4 m one way. House bank − to Freedom XC PRO 3000 BATT −: 120 mm², 1.4 m one way. House bank + to High-current disconnect A: 120 mm², 5 cm one wayHigh-current disconnect B to Freedom XC PRO 3000 BATT +: 120 mm² · 350 A fuse, 1.4 m one wayHouse bank − to Freedom XC PRO 3000 BATT −: 120 mm², 1.4 m one wayHouse bank + to High-current disconnect A: 120 mm², 5 cm one way12 V 400 Ah placeholder bank. Example assumptions: 400 Ah, 400 A continuous discharge and 150 A charging acceptance. These are not verified battery specifications. Replace with the actual bank and check BMS, surge capability and fault current against the inverter/charger manual. Discharge capability of 400 A is an explicit example assumption; verify the actual continuous, surge and cranking capability and the disconnect's ratings.House bank350 A ClassT at battery +++−−High-current battery disconnectHigh-current disconnectABXantrex Freedom XC PRO 3000 120V. The example covers only the 12 V battery connection for standard model 818-3010. It uses the manual's 4/0 AWG minimum (120 mm² in this catalog), a 350 A Class T fuse, 1.4 m main conductors and a 0.05 m positive link to the disconnect. The 1.45 m total positive path and 1.4 m return stay below the manual's 1.5 m limit. The 304 A value is published nominal full-load DC input. Verify actual battery/BMS capability and the complete AC, grounding, transfer and installation requirements separately.Freedom XC PRO 3000BATT +BATT +BATT −BATT −120 mm² · 350 A fuse120 mm²
Xantrex Freedom XC PRO 3000 120V wiring example with 3 components: House bank, High-current disconnect, Freedom XC PRO 3000. 3 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Cable labels are example values; use the equipment instructions and actual installation lengths.

The example covers only the 12 V battery connection for standard model 818-3010. It uses the manual's 4/0 AWG minimum (120 mm² in this catalog), a 350 A Class T fuse, 1.4 m main conductors and a 0.05 m positive link to the disconnect. The 1.45 m total positive path and 1.4 m return stay below the manual's 1.5 m limit. The 304 A value is published nominal full-load DC input. Verify actual battery/BMS capability and the complete AC, grounding, transfer and installation requirements separately. Manufacturer installation manual

Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

1.4 m one way

12 V system

Wire
120 mm² · 4/0 AWG
Example fuse
350 A
Design current
304 A
Voltage drop
1.0%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

The example covers only the 12 V battery connection for standard model 818-3010. It uses the manual's 4/0 AWG minimum (120 mm² in this catalog), a 350 A Class T fuse, 1.4 m main conductors and a 0.05 m positive link to the disconnect. The 1.45 m total positive path and 1.4 m return stay below the manual's 1.5 m limit. The 304 A value is published nominal full-load DC input. Verify actual battery/BMS capability and the complete AC, grounding, transfer and installation requirements separately. Manufacturer installation manual

Show sizes in AWG

Supporting parts

  1. 2.8 m total of 120 mm² (4/0 AWG) marine cable
  2. Terminations for 120 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 350 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 975-0799-01-01 Rev G; standard 818-3010 3000W / 150A column), checked 2026-10-01. Manufacturer documentation →

Which Freedom model is covered?

This entry is the standard Freedom XC PRO 3000, 818-3010, with 12 V battery input, 3000 W continuous AC output and 150 A charging. The Rev G specifications publish 304 A nominal DC input at full inverter load. Marine variants and the non-PRO Freedom XC must not inherit this model’s details indiscriminately.

What are the DC installation requirements?

Printed page 21 calls for 4/0 AWG, each one-way battery cable under 1.5 m / 5 ft, and a 350 A maximum battery fuse. Use a correctly rated battery disconnect and fuse close to the positive source. DC stud torque is 8–10 Nm; the chassis grounding lug has its own lower 2.6 Nm requirement.

How does the AC side work?

Separate AC IN from AC OUT; never backfeed the output from another source. The transfer relay is rated 50 A with 40 A continuous service. AC neutral/earth switching and GFCI compatibility must follow the manual’s application diagram. The 3000 W inverter rating does not mean its DC terminals carry 25 A: that figure belongs to 120 V AC output.

What must be commissioned?

Set battery chemistry, charging current, low-battery behavior and available AC input current. Confirm the battery/BMS can support inverter demand and accept charging. Test both shore-powered charging and loss-of-shore transfer with a suitable load. Preserve ventilation and use the additional drip-protection installation requirements when fitting the standard model in a marine application.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

12V inverter/charger with 3000W continuous 120VAC output, 150A charging and a 50A transfer relay (40A continuous). The manual publishes 304A nominal DC input at full inverter load. Standard 818-3010 and marine variants have different installation hardware; this entry is the standard model.

Nominal voltage
12 V
Compatible systems
12 V
Rated power
3,000 W
Continuous draw
304 A
Rated output
150 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

BATT +

positive · bidi

304 A

BATT −

negative · bidi

304 A

CHASSIS

ground · bidi

—

AC IN L

neutral · input

50 A

AC IN N

neutral · input

50 A

AC OUT L

neutral · output

50 A

AC OUT N

neutral · output

50 A

AC PE

ground · bidi

50 A

A dash means a current rating is not specified here.

Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Freedom XC PRO 3000.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.