Battery

Exide Dual AGM EP800 95Ah wiring diagram

12 V, 95 Ah dual-purpose AGM for starting and house service in boats, motorhomes and campervans. Current Exide specification: 850 A CCA, L05 case, 353 × 175 × 190 mm.

Nominal voltage
12 V
Capacity
95 Ah
Units

Wiring diagram

How the EP800 AGM 95Ah is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Exide Dual AGM EP800 95Ah wiring example with 4 components: EP800 AGM 95Ah, Battery disconnect, Fused DC distribution, DC fridge. 5 cable connections. Crossings are not junctions.Fused DC distribution 1 to DC fridge +: 4 mm² · 15 A fuse, 3 m one way. Fused DC distribution 1 to DC fridge −: 4 mm², 3 m one way. EP800 AGM 95Ah + to Battery disconnect A: 6 mm² · 15 A fuse, 3 m one way. Battery disconnect B to Fused DC distribution IN +: 6 mm² · 15 A fuse, 3 m one way. EP800 AGM 95Ah − to Fused DC distribution IN −: 6 mm², 3 m one wayFused DC distribution 1 to DC fridge +: 4 mm² · 15 A fuse, 3 m one wayFused DC distribution 1 to DC fridge −: 4 mm², 3 m one wayEP800 AGM 95Ah + to Battery disconnect A: 6 mm² · 15 A fuse, 3 m one wayBattery disconnect B to Fused DC distribution IN +: 6 mm² · 15 A fuse, 3 m one wayEP800 AGM 95Ah − to Fused DC distribution IN −: 6 mm², 3 m one wayExide Dual AGM EP800 95AhEP800 AGM 95Ah++−−Main Battery SwitchBattery disconnectABBlue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Dometic CRX-65 Fridge. This 12 V example uses Dometic's 15 A supply protection and a short 1 m run with 6 mm² cable. Check the manual's voltage-specific cable graph for your route. At 24 V, the specified protection is 7.5 A. Running current and the fuse rating describe different things.DC fridge++−−4 mm² · 15 A fuse4 mm²6 mm² · 15 A fuse6 mm² · 15 A fuse
Exide Dual AGM EP800 95Ah wiring example with 4 components: EP800 AGM 95Ah, Battery disconnect, Fused DC distribution, DC fridge. 5 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

Cable sizes depend on the connected equipment, current and cable lengths. Add those details in Crimp to size each run.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with EP800 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

12 V, 95 Ah dual-purpose AGM for starting and house service in boats, motorhomes and campervans. Current Exide specification: 850 A CCA, L05 case, 353 × 175 × 190 mm.

Nominal voltage
12 V
Capacity
95 Ah

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · bidi

—

−

negative · bidi

—

A dash means a current rating is not specified here.

Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Wire sizes and fuse ratings apply to the connected example, not a fixed cable size for this component. Set your actual equipment, current, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with EP800 AGM 95Ah.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.