Blue Sea Systems

Blue Sea 7560 AC Main Circuit Breaker 30A connections

Review the Blue Sea 7560 AC Main Circuit Breaker 30A catalog ratings, AC connection points and installation notes, then add the part to your Crimp diagram.

Connection overview

AC main 30A · 7560 connections.

See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.

Blue Sea 7560 AC Main Circuit Breaker 30A connection overview with 3 components: AC main 30A · 7560, Protected shore supply, 230 V vessel circuits. 5 cable connections. Crossings are not junctions.Protected shore supply L to AC main 30A · 7560 LINE L. Protected shore supply N to AC main 30A · 7560 LINE N. AC main 30A · 7560 LOAD L to 230 V vessel circuits L. AC main 30A · 7560 LOAD N to 230 V vessel circuits N. Protected shore supply PE to 230 V vessel circuits PE: Continuous protective earthProtected shore supply L to AC main 30A · 7560 LINE LProtected shore supply N to AC main 30A · 7560 LINE NAC main 30A · 7560 LOAD L to 230 V vessel circuits LAC main 30A · 7560 LOAD N to 230 V vessel circuits NProtected shore supply PE to 230 V vessel circuits PE: Continuous protective earthBlue Sea 7560 AC Main Circuit Breaker 30A. AC breaker contact overview: line and neutral pass through separate poles, while protective earth bypasses the breaker. Supply protection is assumed; select all required main, branch and leakage protection separately. Crimp does not simulate automatic trips or verify AC protection coordination. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.AC main 30A · 7560LINE LLINE LLINE NLOAD LLOAD LLOAD NProtected shore supply. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.Protected shore supplyLLNPEPE230 V vessel circuits. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.230 V vessel circuitsLLNPEPE
Blue Sea 7560 AC Main Circuit Breaker 30A connection overview with 3 components: AC main 30A · 7560, Protected shore supply, 230 V vessel circuits. 5 cable connections. Crossings are not junctions.AC breaker contact overview: line and neutral pass through separate poles, while protective earth bypasses the breaker. Supply protection is assumed; select all required main, branch and leakage protection separately. Crimp does not simulate automatic trips or verify AC protection coordination. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.
Edit this connection overview

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Manufacturer product specifications), checked 2026-10-19. Manufacturer documentation →

Which breaker is this?

Blue Sea 7560: Two-pole, 30 A AC magnetic-hydraulic breaker with 5000 A interrupt capacity. The manufacturer describes switching line and neutral on a 120 V main. Its maximum AC rating is 240 V; confirm pole count for the actual supply arrangement.

How are the conductors connected?

The symbol keeps LINE L and LOAD L on one pole, and LINE N and LOAD N on the other. Both open together. Protective earth bypasses the breaker continuously; it has no PE terminal. The example assumes a protected supply and does not specify a complete main, branch or leakage-protection installation.

What does Crimp simulate?

Select On, Off or Tripped to change the contacts manually. Crimp does not calculate AC fault currents, automatic trip times, leakage detection or protection coordination. The connection overview has no calculated cable or fuse recommendation. Check the complete installation against the manufacturer's instructions.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

C-Series 30 A magnetic-hydraulic AC main circuit breaker, two poles, rated for 120/240 V AC with 5000 A interrupt capacity. These AC breakers open both poles together and have no RCD/ELCI leakage protection. The symbol switches line and neutral; protective earth bypasses it. Crimp models manual contact states, not automatic tripping or AC protection coordination.

The map identifies line, neutral and protective-earth connections. This page does not calculate an AC cable size or protection rating.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

LINE L

neutral · input

30 A

LINE N

neutral · input

30 A

LOAD L

neutral · output

30 A

LOAD N

neutral · output

30 A
Sources and connection guidance

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

AC planning boundary. The drawing identifies conductors and connection points; supported switching states show contact continuity only. Crimp does not calculate AC load flow or verify fault protection, leakage trips, source isolation or grounding. This overview does not calculate cable sizes or validate protective devices. Follow the complete manufacturer installation instructions.

Read about the DC sizing method and its limits

Next step

Plan your installation with AC main 30A · 7560.

Open the connection overview as a new project, or add this component to a diagram you already have.