Load

Attwood Turbo 4000 Series II 1749-4 wiring diagram

12 V water-resistant 4-inch blower; manufacturer specifies a 5 A fuse and 2.9 A draw at 13.6 V. The 230 CFM free-air rating drops with duct and vent resistance. Yellow lead is positive and black negative. Not a substitute for a complete ventilation design. Terminal values are protection-based planning bounds.

Nominal voltage
12 V
Compatible systems
12 V
Continuous draw
2.9 A

Wiring diagram

How the Turbo 4000 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Attwood Turbo 4000 Series II 1749-4 wiring example with 3 components: House bank, Fused DC distribution, Turbo 4000. 4 cable connections. Crossings are not junctions.Fused DC distribution 1 to Turbo 4000 +: 16 AWG · 5 A fuse, 10 ft one way. Fused DC distribution 1 to Turbo 4000 −: 16 AWG, 10 ft one way. House bank + to Fused DC distribution IN +: 16 AWG · 5 A fuse, 1.0 ft one way. House bank − to Fused DC distribution IN −: 16 AWG, 1.0 ft one wayFused DC distribution 1 to Turbo 4000 +: 16 AWG · 5 A fuse, 10 ft one wayFused DC distribution 1 to Turbo 4000 −: 16 AWG, 10 ft one wayHouse bank + to Fused DC distribution IN +: 16 AWG · 5 A fuse, 1.0 ft one wayHouse bank − to Fused DC distribution IN −: 16 AWG, 1.0 ft one way12 V 200 Ah house bankHouse bank++−−Blue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Attwood Turbo 4000 Series II 1749-4. The 1749-4 example uses Attwood's 5 A fuse and 2.9 A running figure at 13.6 V. The positive feed also needs the helm switch. Verify duct routing, dryness, flow direction, actual cable routing and the engine-compartment voltage-drop allowance.Turbo 4000++−−16 AWG · 5 A fuse16 AWG16 AWG · 5 A fuse16 AWG
Attwood Turbo 4000 Series II 1749-4 wiring example with 3 components: House bank, Fused DC distribution, Turbo 4000. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Cable labels are example values; use the equipment instructions and actual installation lengths.

The 1749-4 example uses Attwood's 5 A fuse and 2.9 A running figure at 13.6 V. The positive feed also needs the helm switch. Verify duct routing, dryness, flow direction, actual cable routing and the engine-compartment voltage-drop allowance. Manufacturer installation manual

Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

10 ft one way

12 V system

Wire
16 AWG · 1.5 mm²
Example fuse
5 A
Design current
2.9 A
Voltage drop
1.7%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

The 1749-4 example uses Attwood's 5 A fuse and 2.9 A running figure at 13.6 V. The positive feed also needs the helm switch. Verify duct routing, dryness, flow direction, actual cable routing and the engine-compartment voltage-drop allowance. Manufacturer installation manual

Show sizes in mm²

Supporting parts

  1. 20 ft total of 16 AWG (1.5 mm²) marine cable
  2. Terminations for 16 AWG cable, matched to the equipment's screw terminals, leads or studs
  3. 5 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 69465 Rev A, 09/01; current Attwood catalog pp. 36–38), checked 2026-10-01. Manufacturer documentation →

A ventilation blower, not a bilge pump

1749-4 is the retail 12 V water-resistant Turbo 4000 Series II blower for 4-inch ventilation hose. Its role is to move air from the engine/bilge space to an exterior vent. Water resistance does not authorize submersion or mounting where bilge water is drawn through it.

The manufacturer gives 230 CFM open flow and 125 CFM in a specified test system with duct, a bend, collector and vent. Use the installed ventilation path when assessing airflow; the free-air number alone does not establish adequate ventilation for an engine compartment.

Wire for the blower's actual running load

Connect yellow positive through the helm on/off switch and specified 5 A fuse, with black negative return. The reviewed instruction table gives 2.9 A at 13.6 V. The catalog uses that operating point; it does not borrow the 24 V blower's current or treat the fuse as consumption. No measured starting surge was recovered.

Size extensions for the actual circuit length, ampacity and voltage drop, and keep connections protected from moisture. The older instruction sheet shows a maximum source-to-fuse distance; use the protection placement required for the actual installation rather than assuming that old drawing makes every long unprotected battery lead acceptable. The catalog terminal limit is a protection-based planning bound.

Mount the air path to stay dry

Mount high above the bilge on a suitable surface, clear of spray and deck wash, with the flow arrow pointing toward the exhaust vent. Follow the recommended angled orientation so moisture does not collect in the housing. Secure the hose over the retention features without crushing the plastic.

Route the intake pickup toward the low part of the space being ventilated while keeping it above possible bilge-water submersion. Run the discharge to the exterior vent with few bends and no collapsed hose. An apparently healthy spinning fan can move very little useful air through a blocked or badly routed duct.

Use and inspect before starting an engine

Attwood directs operation for at least four minutes before engine start, followed by checking the compartment for fuel-vapor odor, and operation below cruising speed. The sheet also says not to operate while refueling or above its 71 °C ambient limit. Keep the blower reminder label at the helm.

Commission by checking the direction and useful flow at the exterior discharge, not only the sound of the motor. If flow is poor, inspect duct restrictions, pickup obstruction and rotation/airflow orientation. If it is silent, check voltage at the blower, switch and fuse. Isolate power before servicing; if fuel vapor remains, resolve its source before engine starting.

Manual and evidence

Attwood installation instructions, manufacturer PDF hosted by distributor, p. 1, establishes wiring, current, fuse, ducting and operating checks. Current Attwood catalog confirms the 1749-4 retail identity; pp. 36–38 distinguish voltage variants and performance. The original instructions and hash are retained locally.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

12 V water-resistant 4-inch blower; manufacturer specifies a 5 A fuse and 2.9 A draw at 13.6 V. The 230 CFM free-air rating drops with duct and vent resistance. Yellow lead is positive and black negative. Not a substitute for a complete ventilation design. Terminal values are protection-based planning bounds.

Nominal voltage
12 V
Compatible systems
12 V
Continuous draw
2.9 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · input

5 A

−

negative · input

5 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Turbo 4000.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Free for up to 10 equipment components, with no account needed. Cables, busbars and fuse hardware do not count toward the limit. Your drawing saves in this browser. File exports are included with Crimp Pro.