Load

Caframo Sirocco II 7010 wiring diagram

Dry-cabin fan with automatic 12/24 V sensing, locking gimbal and 3/6/9/12-hour timer. High-speed current is 0.35 A at 12 V or 0.21 A at 24 V. This is a cabin circulation fan; it is not an ignition-protected bilge blower.

Nominal voltage
12 V
Compatible systems
12 V / 24 V
Continuous draw
0.4 A

Wiring diagram

How the Sirocco II 7010 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Caframo Sirocco II 7010 wiring example with 3 components: House bank, Fused DC distribution, Sirocco II 7010. 4 cable connections. Crossings are not junctions.Fused DC distribution 1 to Sirocco II 7010 +: 1.5 mm² · 1 A fuse, 3 m one way. Fused DC distribution 1 to Sirocco II 7010 −: 1.5 mm², 3 m one way. House bank + to Fused DC distribution IN +: 1.5 mm² · 1 A fuse, 30 cm one way. House bank − to Fused DC distribution IN −: 1.5 mm², 30 cm one wayFused DC distribution 1 to Sirocco II 7010 +: 1.5 mm² · 1 A fuse, 3 m one wayFused DC distribution 1 to Sirocco II 7010 −: 1.5 mm², 3 m one wayHouse bank + to Fused DC distribution IN +: 1.5 mm² · 1 A fuse, 30 cm one wayHouse bank − to Fused DC distribution IN −: 1.5 mm², 30 cm one way12 V 200 Ah house bankHouse bank++−−Blue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Caframo Sirocco II 7010Sirocco II 7010++−−1.5 mm² · 1 A fuse1.5 mm²1.5 mm² · 1 A fuse1.5 mm²
Caframo Sirocco II 7010 wiring example with 3 components: House bank, Fused DC distribution, Sirocco II 7010. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Cable labels are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
1.5 mm² · 16 AWG
Example fuse
1 A
Design current
0.3 A
Voltage drop
0.2%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Show sizes in AWG

Supporting parts

  1. 6.1 m total of 1.5 mm² (16 AWG) marine cable
  2. Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 1 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Official 7010 Sirocco II online operating manual, reviewed 2026-10-01), checked 2026-10-01. Manufacturer documentation →

Which Sirocco II and what current?

The 7010 Sirocco II is a cabin circulation fan with automatic 12/24 V sensing. The official online operating manual covers white 7010CAWBX and black 7010CABBX. At 12 V, low/medium/high speed draws 0.12/0.22/0.35 A; at 24 V those values are 0.06/0.11/0.21 A. The catalog uses the 12 V high-speed value. This is not an ignition-protected engine-space or bilge blower.

How should it be mounted and wired?

Use the backing plate and the manual's six #6 fasteners on a suitable structure. Adhesive positioning alone does not retain the fan in a moving vehicle. Leave enough clearance for the gimbal to move without striking furniture or trapping its wiring. Wire the marked positive and negative connections at the base, retaining the supplied nuts and lock washers and tightening them securely as instructed.

The manual describes reverse-polarity and overcurrent protection but does not prescribe an external branch-fuse value. A protected supply is still needed for the cable from the DC distribution point. The 0.35 A terminal envelope in this catalog is the documented 12 V load, not a hardware connector ampacity or permission to leave the feed unprotected.

How do the controls work?

Set the desired direction and lock the gimbal before operation. The power/speed button steps through the three speeds; the timer offers 3, 6, 9 or 12 hours. Check the illuminated timer indicators so an intentional timed shutdown is not mistaken for a power fault. Use lower speed or shorter run time when quiet operation or energy saving matters.

What are the limits and routine checks?

Install in a dry cabin location; this fan is not intended for outdoor exposure, spray or immersion. Keep fingers and loose objects clear of the blades. Isolate power before cleaning, and remove dust gently without forcing the blades or controls. If it fails to start, check the polarity at the fan, the upstream protective device, the base-terminal connections and supply voltage. Use the manual's fault guidance before dismantling the fan. The retained source is the manufacturer's full HTML manual; a manufacturer-hosted downloadable PDF was not located.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Dry-cabin fan with automatic 12/24 V sensing, locking gimbal and 3/6/9/12-hour timer. High-speed current is 0.35 A at 12 V or 0.21 A at 24 V. This is a cabin circulation fan; it is not an ignition-protected bilge blower.

Nominal voltage
12 V
Compatible systems
12 V / 24 V
Continuous draw
0.4 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · input

0.35 A

−

negative · input

0.35 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Sirocco II 7010.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Free for up to 10 equipment components, with no account needed. Cables, busbars and fuse hardware do not count toward the limit. Your drawing saves in this browser. File exports are included with Crimp Pro.