Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
2.5 mm² · 13 AWG
Example fuse
10 A
Design current
5 A
Voltage drop
1.8%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

This supply example retains the manufacturer's 10 A fuse. Follow the complete installation notes for connector polarity, mounting, controls and commissioning; verify the actual cable route and equipment revision. Manufacturer installation manual

Show sizes in AWG

Wiring diagram

How the IC-M330GE is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Icom IC-M330GE VHF Radio wiring example with 3 components: House bank, Fused DC distribution, IC-M330GE. 4 cable connections. Crossings are not junctions.Fused DC distribution 1 to IC-M330GE Red +: 2.5 mm² · 10 A fuse, 3 m one way. Fused DC distribution 1 to IC-M330GE Black −: 2.5 mm², 3 m one way. House bank + to Fused DC distribution IN +: 2.5 mm² · 7.5 A fuse, 30 cm one way. House bank − to Fused DC distribution IN −: 2.5 mm², 30 cm one wayFused DC distribution 1 to IC-M330GE Red +: 2.5 mm² · 10 A fuse, 3 m one wayFused DC distribution 1 to IC-M330GE Black −: 2.5 mm², 3 m one wayHouse bank + to Fused DC distribution IN +: 2.5 mm² · 7.5 A fuse, 30 cm one wayHouse bank − to Fused DC distribution IN −: 2.5 mm², 30 cm one way12 V 200 Ah house bankHouse bank++−−Blue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Icom IC-M330GE VHF Radio. This supply example retains the manufacturer's 10 A fuse. Follow the complete installation notes for connector polarity, mounting, controls and commissioning; verify the actual cable route and equipment revision.IC-M330GERed +Red +Black −Black −2.5 mm² · 10 A fuse2.5 mm²2.5 mm² · 7.5 A fuse2.5 mm²
Icom IC-M330GE VHF Radio wiring example with 3 components: House bank, Fused DC distribution, IC-M330GE. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Cable labels are example values; use the equipment instructions and actual installation lengths.Scroll sideways to inspect all components and connections.

This supply example retains the manufacturer's 10 A fuse. Follow the complete installation notes for connector polarity, mounting, controls and commissioning; verify the actual cable route and equipment revision. Manufacturer installation manual

Edit this wiring example

Installation notes

Connections and installation requirements.

Guidance for this model, with sources linked beside the relevant advice.

Verified against the manufacturer's documentation (rev. A7420D-1EX-10, September 2023), checked 2026-10-01. Manufacturer documentation →

Select the GE variant and its supply

This record covers IC-M330GE with the supplied GPS antenna and European channel variant. The operating range is 10.8–15.6 V DC, nominal 13.8 V with negative ground. It must not be connected directly to a 24 V bank. The manual states up to 5 A at 25 W transmit and 1 A at maximum audio, both at 13.8 V. Use the transmit value for supply planning; radio use and receive time determine daily energy.

Protect the DC feed separately from the RF system

Connect the supplied red positive and black negative cable, retaining its F 250 V 10 A fuse. Here 250 V is the fuse’s voltage rating, not the radio supply. Do not increase fuse current if it opens: find the fault first. Protect joined power, NMEA and speaker conductors from water as shown in the manual. The separate rear ground terminal is for the vessel grounding/interference arrangement; it does not replace the black DC return.

Identify the data and antenna interfaces

The VHF antenna uses a PL-259 connector on the radio’s antenna socket. Never transmit without an appropriate antenna. The supplied GPS antenna needs a clear sky view. NMEA 0183 input is yellow A/+ and green B/−; output is white A/+ and brown B/−. These are data pairs and must not be connected as power. The symbol keeps them as signal markers, with no implied DC continuity.

Commission DSC deliberately

Enter and verify the assigned MMSI and any region-specific identifiers following the manual before relying on DSC. Check that the display has valid position and time from GNSS or a compatible NMEA source. Test receive audio and an appropriate routine radio check; do not send a distress alert to test installation. If the radio resets on transmit, measure voltage at its power connector during transmission and inspect joints. If it receives but has poor transmit range, inspect the antenna/coax rather than increasing DC fuse size.

Manual and scope

Icom installation manual, A7420D-1EX-10, September 2023; printed pp. 53–58 for connections, fuse, mounting and electrical specifications; MMSI and DSC chapters. The original PDF is retained in the marine source ledger. The drawing represents the identified electrical interfaces; it does not simulate the equipment’s mechanical performance, radio signals or fluid system. Unpublished connector ampacity and startup current remain unspecified.

Build it out

Connect it to the rest of your system.

Add IC-M330GE to your diagram, then connect your batteries, chargers and loads. Crimp calculates cable sizes and checks the connections as you draw.

Every cable you draw there is sized against ABYC E-11, from the same tables as the reference on this page.

Technical reference

Specifications, terminals and supporting parts.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Nominal voltage
12 V
Compatible systems
12 V
Continuous draw
5 A

Supporting parts

  1. 6.1 m total of 2.5 mm² (13 AWG) marine cable
  2. Terminations for 2.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 10 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

Red +

pos

positive · input

—

Black −

neg

negative · input

—

Ground

ground

ground · bidi

—

NMEA 0183

nmea

signal · bidi

—

VHF/GPS RF

antenna

signal · bidi

—

A dash means a current rating is not specified here.

Method & provenance

Where the specifications and sizing come from.

Manufacturer specifications describe the equipment. Crimp calculates cable results from the circuit and assumptions you enter.

From the maker

What the catalog says

Manufacturer, model, ratings and which terminal does what come from the catalog. A newer revision, or the nameplate on the unit in your hand, can say something different — when it does, the nameplate wins.

ABYC E-11

What Crimp worked out

Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. The run length and the current above are what drive the result. Crimp doesn't know how warm your space gets; draw the cable inside an engine-bay zone on the canvas and it sizes for the heat.

Read how the sizing works

Next step

Plan your installation with IC-M330GE.

Open this example as a new project. Add your equipment and cable lengths, then review the sizing and checks for your setup.