Component folio · Load · Shurflo

Shurflo Aqua King II 4008

Model 4008-101-E65

3.0 GPM on-demand diaphragm pump, 55 PSI shut-off. Draws up to 7.5 A at 12 V; Shurflo recommends a 10 A fuse. The pressure switch runs it only while a tap is open.

Open in Crimp →
Shurflo Aqua King II 4008
Shurflo Aqua King II 4008 · 2 terminals
01 — Wiring diagram

How the Aqua King 4008 is wired

Shurflo Aqua King II 4008 wiring diagram WIRING DIAGRAM Shurflo Aqua King II 4008 wiring diagram 12 V battery bank Supplies this load Aqua King 4008 Shurflo · 4008-101-E65 15 A 13 AWG (2.5 mm²) → + 13 AWG (2.5 mm²) → − 10 ft one way crimp.studio 7.5 A · 2.7% drop · ABYC E-11
Shurflo Aqua King II 4008 wiring diagram, 13 AWG (2.5 mm²) positive feed protected by a 15 A fuse and a matching negative return between the 12 V battery bank and the unit.

The run drawn here is the 10 ft reference run sized below. Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. Confirm your own run length, routing and terminations before ordering — open this part in the designer to size it against your actual system.

02 — Reference run

What size cable and fuse does the Aqua King 4008 need?

Conductor13 AWG2.5 mm²
Fuse15 Apositive run
Voltage drop2.7%10 ft one way
Design current7.5 A12 V system

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The design current is the part's continuous draw. The Crimp engine applies its ordinary continuous-load headroom, voltage-drop budget, terminal clamp, and standard fuse ladder. The 10 ft one-way run is a stated reference, not a universal installation prescription.

03 — Catalog specification

Shurflo Aqua King II 4008 specifications and terminal map

Compatible systems
12 V
Continuous draw
7.5 A
Surge current
10 A

Terminal map

TerminalPolarityDirectionRating
+positiveinput10 A
negativeinput10 A
04 — Supporting parts

What else you need to wire the Aqua King 4008

  • 20 ft total of 13 AWG (2.5 mm²) marine cable
  • Four 13 AWG cable lugs matched to the equipment studs
  • 15 A fuse and holder on the positive run
  • Heat-shrink, strain relief, and terminal boots sized to the cable

Start from this part

Open the canvas with the Aqua King 4008 already placed, then wire the rest of the system around it. Nothing to install and no sign-up — the project is saved in this browser, and you can download the file whenever you want it.

Open the canvas →

05 — Method & provenance

What is known, assumed, and computed.

Catalog profile

The manufacturer, model, ratings and terminal map are maintained as planning data in Crimp's component catalog. Confirm the current manufacturer manual, exact revision and installed nameplate before ordering or wiring.

Engine reference

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The published conductor, fuse and voltage-drop result uses the visible reference length and current basis; it is not a universal installation prescription.

Read the complete methodology →