Crimp
Component folio · Load · Dometic

Dometic CFX3 35

Model CFX3 35

Portable compressor fridge/freezer, 36 L. Rated 7.5 A at 12 V; Dometic rates energy use at 352 Wh per 24 h (about 29 Ah/day at 12 V) at 5 °C interior and 25 °C ambient. Runs on 12/24 V DC or mains.

Open in Crimp →
Dometic CFX3 35
Dometic CFX3 35 · 2 terminals
01 — Reference run

A sizing result with its assumptions attached.

Conductor13 AWG2.5 mm²
Fuse15 Apositive run
Voltage drop2.6%9.8 ft one way
Design current7.5 A12 V system

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The design current is the part's continuous draw. The Crimp engine applies its ordinary continuous-load headroom, voltage-drop budget, terminal clamp, and standard fuse ladder. The 9.8 ft one-way run is a stated reference, not a universal installation prescription.

02 — Catalog specification

The part the engine actually sees.

Compatible systems
12 V / 24 V
Rated power
90 W
Continuous draw
7.5 A
Surge current
9 A

Terminal map

TerminalPolarityDirectionRating
+positiveinput8 A
negativeinput8 A
03 — Supporting parts

What belongs around it.

  • 19.7 ft total of 13 AWG (2.5 mm²) marine cable
  • Four 13 AWG cable lugs matched to the equipment studs
  • 15 A fuse and holder on the positive run
  • Heat-shrink, strain relief, and terminal boots sized to the cable

See what it changes in your system

With JavaScript enabled, describe your existing boat, van, or off-grid system here. The model supplies topology; Crimp's engine computes the attachment, resized runs, checks, and supporting basket.

04 — Method & provenance

What is known, assumed, and computed.

Catalog profile

The manufacturer, model, ratings and terminal map are maintained as planning data in Crimp's component catalog. Confirm the current manufacturer manual, exact revision and installed nameplate before ordering or wiring.

Engine reference

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The published conductor, fuse and voltage-drop result uses the visible reference length and current basis; it is not a universal installation prescription.

Read the complete methodology →
05 — Related components

Comparable parts in the same system role.

Browse all load profiles →