Skylla-IP65 12/70 (1+1) (SKY012070000)
Victron Skylla-IP65 12/70 (1+1) wiring diagram
Skylla-IP65 12/70 (1+1), SKY012070000: 70A main output plus a 3A starter-battery output sharing −BAT. Input 90–265 VAC, 12 A maximum; full current up to 40°C. IP65 steel case with a separate earth point.
- Compatible systems
- 12 V
- Rated output
- 70 A
Wiring diagram
How the Skylla-IP65 70A (1+1) is wired.
Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.
The example connects +BAT1 and −BAT to one placeholder house bank with 16 mm² cable: 1.5 m to the disconnect, a 0.3 m battery-positive lead and a 1.5 m return. 16 mm² is the largest cable whose lug fits the battery glands, so keep runs short at 70 A. Victron names no fuse rating; the battery-positive fuse is a planning result that protects the cable. AC supply, the case earth point, sensing and VE.Can are outside the example. Manufacturer installation manual
Edit this wiring exampleCable sizing for this example
Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.
1.5 m one way
12 V system
- Wire
- 16 mm² · 6 AWG
- Example fuse
- 100 A
- Design current
- 70 A
- Voltage drop
- 1.9%
Sized against ABYC E-11. The design current is the unit's rated output. The length is one way; voltage drop includes an equal-length return.
Already have a cable size? Check a simple copper run at your current and length with the DC voltage drop calculator in mm² or AWG.
Run-length and manufacturer assumptions
The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.
The example connects +BAT1 and −BAT to one placeholder house bank with 16 mm² cable: 1.5 m to the disconnect, a 0.3 m battery-positive lead and a 1.5 m return. 16 mm² is the largest cable whose lug fits the battery glands, so keep runs short at 70 A. Victron names no fuse rating; the battery-positive fuse is a planning result that protects the cable. AC supply, the case earth point, sensing and VE.Can are outside the example. Manufacturer installation manual
Supporting parts
- 3.3 m total of 16 mm² (6 AWG) marine cable
- Terminations for 16 mm² cable, matched to the equipment's screw terminals, leads or studs
- 100 A fuse and holder on the positive run
- Heat-shrink, strain relief and terminal boots sized to the cable
Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.
Installation notes
Before you install.
Open a question for model-specific guidance and sources.
Verified against the manufacturer's documentation (rev. Manual Rev 06 — 10/2023), checked 2026-11-25. Manufacturer documentation →
Which Skylla-IP65 12/70 (1+1) is this?
This is the Victron Skylla-IP65 12/70 (1+1), part number SKY012070000: a 12 V mains battery charger with a 70 A main output and a 3 A starter-battery output. The datasheet lists 90–265 VAC input at 45–65 Hz and lists a battery capacity of 350–700 Ah.
The 12/70 (3) has three full-current outputs instead and has its own page. The 24/35 versions are for 24 V systems.
How is the Skylla-IP65 12/70 (1+1) wired?
The house battery connects to +BAT1 and −BAT on M6 bolts. The starter battery's positive goes to STARTER + on the grey terminal block, and its negative also goes to −BAT (manual, starter battery). Use 1.5–6 mm² wire for the starter output. Crimp draws the one physical −BAT bolt. When both banks share it, automatic return-branch sizing remains provisional; verify the starter circuit against the manual’s 3 A output and cable guidance.
Mains goes to L, N and the earth terminal on the AC connector. The separate CASE EARTH bolt on the case connects to the hull, earth plate or vehicle frame (manual, earth). The battery outputs float relative to that earth point.
Victron's minimum battery cable for the 12/70 is 10 mm² up to 1.5 m and 16 mm² from 1.5 to 6 m, with the charger within 6 m of the battery. The manual asks for fuses and breakers on the connection cables without naming a rating; the page's technical reference sizes the example fuse.
What should I bear in mind with the Skylla-IP65 12/70 (1+1)?
- No reverse-polarity protection on the main or starter battery: connect + to +BAT1 and − to −BAT with the mains off (manual).
- Starter output is one-way: the starter battery can draw from the main bank, but the main bank cannot draw from the starter battery.
- Heat derating: full current up to 40 °C, falling to 60 % at 50 °C and 40 % at 60 °C (specifications).
- Shore supply: maximum input current is 12 A; the input limit is set to 10.5 A from the factory and can be lowered with a GX device or Skylla-i Control panel (manual).
- Lithium: use the remote on/off port with a BMS, or VE.Can control. Voltage sense, temperature sense and the alarm relay are not drawn.
What do owners and installers say about the Skylla-IP65 12/70 (1+1)?
No model-specific reliability pattern is established here. For low charging current, first check the charge stage, shore-current limit and temperature rather than assuming a fault. Victron's operation guide explains the display and reduced-current behavior; its troubleshooting chapter covers fault checks.
What belongs around the Skylla-IP65 12/70 (1+1)?
The example covers one house-bank DC connection. Add the actual battery, positive-side protection and disconnect, then plan the AC supply, protective earth and separate case-earth connection from the manual. Other banks, sensing, BMS control and VE.Can need their own connections; the example does not validate them. Use the wire-size calculator for another run, or edit the example above in Crimp. Search SKY012070000 in the component picker to select this exact variant.
Technical reference
Specifications and terminal map.
Check the model, ratings and connection points against your own unit before choosing installation hardware.
Catalog specification
Skylla-IP65 12/70 (1+1), SKY012070000: 70A main output plus a 3A starter-battery output sharing −BAT. Input 90–265 VAC, 12 A maximum; full current up to 40°C. IP65 steel case with a separate earth point.
- Compatible systems
- 12 V
- Rated output
- 70 A
Terminal map
+BAT outputs and −BAT are M6 bolts; every battery negative returns to the single −BAT. On the (1+1), STARTER + is limited to 3 A and uses that same −BAT bolt. Shared-return branch sizing needs verification when both banks are drawn. The outputs are not protected against reverse polarity. CASE EARTH is the case earth point, separate from the floating battery outputs.
AC L
neutral · input
AC N
neutral · input
AC PE
ground · bidi
CASE EARTH
ground · bidi
+BAT1
positive · output
−BAT
negative · output
STARTER +
positive · output
A dash means a current rating is not specified here.
Sources and sizing method
Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.
Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.
Read how the sizing worksNext step
Plan your installation with Skylla-IP65 70A (1+1).
Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.
Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.