Outgoing + return cable
4.86% drop
Above the 3% comparison target
- Voltage lost in the cable
- 0.583 V
- Voltage at the load
- 11.42 V
- Power dissipated in the cable
- 11.67 W
Voltage-drop comparison only. Ampacity, fuse protection and the equipment’s minimum voltage are not verified.
The full circuit contains 10 m of conductor. At 20 A, its calculated loss is 0.583 V, leaving about 11.42 V at the load from a 12 V supply. That is 4.86%, above a 3% target.
Shortening the route or increasing the conductor area reduces this loss. If you change system voltage, calculate the new load current too: a fixed-power appliance draws a different current at 24 V.
The calculation keeps current constant. Actual equipment may draw more current, reduce output or stop as its supply voltage falls. Check the manufacturer’s operating range.