Crimp
Component folio · Solar · Jinko

Jinko JKM440M-6TL4 440W

Model JKM440M-6TL4-V

440W Tiger Pro 120-half-cell mono PERC panel, residential voltage (Vmp 33.8V, Voc 40.9V) — needs an MPPT controller with Voc headroom on a 12V bank. MC4 connectors.

Open in Crimp →
Jinko JKM440M-6TL4 440W
Jinko JKM440M-6TL4 440W · 2 terminals
01 — Wiring diagram

How the Jinko 440W is wired

Jinko JKM440M-6TL4 440W wiring diagram WIRING DIAGRAM Jinko JKM440M-6TL4 440W wiring diagram 33.82 V battery bank Supplies this load Jinko 440W Jinko · JKM440M-6TL4-V 20 A 13 AWG (2.5 mm²) → + 13 AWG (2.5 mm²) → − 10 ft one way crimp.studio 13 A · 1.6% drop · ABYC E-11
Jinko JKM440M-6TL4 440W wiring diagram, 13 AWG (2.5 mm²) positive feed protected by a 20 A fuse and a matching negative return between the 33.82 V battery bank and the unit.

The run drawn here is the 10 ft reference run sized below. Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. Confirm your own run length, routing and terminations before ordering — open this part in the designer to size it against your actual system.

02 — Reference run

What size cable and fuse does the Jinko 440W need?

Conductor13 AWG2.5 mm²
Fuse20 Apositive run
Voltage drop1.6%10 ft one way
Design current13 A33.82 V panel Vmp

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The design current is the part's continuous draw. The Crimp engine applies its ordinary continuous-load headroom, voltage-drop budget, terminal clamp, and standard fuse ladder. The 10 ft one-way run is a stated reference, not a universal installation prescription.

03 — Catalog specification

Jinko JKM440M-6TL4 440W specifications and terminal map

Nominal voltage
34 V
Rated power
440 W
Rated output
13 A
Panel open-circuit voltage
41 V

Terminal map

TerminalPolarityDirectionRating
+positivebidi20 A
negativebidi20 A
04 — Supporting parts

What else you need to wire the Jinko 440W

  • 20 ft total of 13 AWG (2.5 mm²) marine cable
  • Four 13 AWG cable lugs matched to the equipment studs
  • 20 A fuse and holder on the positive run
  • Heat-shrink, strain relief, and terminal boots sized to the cable

Start from this part

Open the canvas with the Jinko 440W already placed, then wire the rest of the system around it. Nothing to install and no sign-up — the project is saved in this browser, and you can download the file whenever you want it.

Open the canvas →

05 — Method & provenance

What is known, assumed, and computed.

Catalog profile

The manufacturer, model, ratings and terminal map are maintained as planning data in Crimp's component catalog. Confirm the current manufacturer manual, exact revision and installed nameplate before ordering or wiring.

Engine reference

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The published conductor, fuse and voltage-drop result uses the visible reference length and current basis; it is not a universal installation prescription.

Read the complete methodology →
06 — Related components

Alternatives to the Jinko 440W

Browse all solar profiles →