Blue Sea 5029 ST Blade Fuse Block wiring diagram

12-circuit ATO/ATC blade fuse block with cover and a common positive bus. No negative bus: connect load returns to a separate negative bus. 100 A maximum per block, 30 A per circuit, 32 V DC maximum. Fuses sold separately.

Compatible systems
12 V / 24 V
Units

Wiring diagram

How the BS 5029 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Blue Sea 5029 ST Blade Fuse Block wiring example with 3 components: Source bank, BS 5029, Reference load. 3 cable connections. Crossings are not junctions.Source bank + to BS 5029 IN +: 10 mm² · 25 A fuse, 3 m one way. BS 5029 1 to Reference load +: 10 mm² · 25 A fuse, 3 m one way. Source bank − to Reference load −: 10 mm², 3 m one waySource bank + to BS 5029 IN +: 10 mm² · 25 A fuse, 3 m one wayBS 5029 1 to Reference load +: 10 mm² · 25 A fuse, 3 m one waySource bank − to Reference load −: 10 mm², 3 m one way12 V 200 Ah source bankSource bank++−−Blue Sea 5029 ST Blade Fuse Block. Blue Sea 5029: twelve ATO/ATC fused positive branches, 100 A maximum total, 30 A per circuit and 32 V DC maximum. Load returns need a separate negative bus. The example load and fuse ratings are planning choices; verify actual loads, conductors, source protection and fuse interrupt ratings. Fuses are sold separately.BS 5029IN +IN +1112 V reference loadReference load++−−10 mm² · 25 A fuse10 mm² · 25 A fuse
Blue Sea 5029 ST Blade Fuse Block wiring example with 3 components: Source bank, BS 5029, Reference load. 3 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.

Blue Sea 5029: twelve ATO/ATC fused positive branches, 100 A maximum total, 30 A per circuit and 32 V DC maximum. Load returns need a separate negative bus. The example load and fuse ratings are planning choices; verify actual loads, conductors, source protection and fuse interrupt ratings. Fuses are sold separately. Manufacturer installation manual

Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

Cable sizes depend on the connected equipment, current and cable lengths. Add those details in Crimp to size each run.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation, checked 2026-11-10. Manufacturer documentation →

What does the Blue Sea 5029 connect?

The Blue Sea 5029 ST Blade Fuse Block distributes one positive feed to twelve ATO/ATC fused circuits and includes a cover. It has no negative bus. Connect each load's negative return to a separate negative bus connected to the source. The 5026 is the twelve-circuit version with a negative bus.

The manufacturer's specifications set limits of 100 A for the whole block, 30 A per circuit and 32 V DC. Fuses are sold separately. These limits do not choose the correct fuse for a particular load or cable.

How are the terminals arranged?

IN + represents the common #10-32 feed stud. Terminals 1–12 are the #8-32 branch screws, each supplied through its own fuse position. The 5029 wiring schematic shows the single common positive bus and twelve fused outputs.

The block's branch fuses do not protect its incoming cable. Select upstream protection for that cable and verify the installed fuse's DC interrupt rating against the actual source. The editable example uses one illustrative load with a separate negative return; replace its demand and cable lengths with your installation values.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

12-circuit ATO/ATC blade fuse block with cover and a common positive bus. No negative bus: connect load returns to a separate negative bus. 100 A maximum per block, 30 A per circuit, 32 V DC maximum. Fuses sold separately.

Compatible systems
12 V / 24 V

Terminal map

IN + is the common #10-32 positive feed stud; 1–12 are the fused #8-32 branch screws. There is no negative bus. Feed stud torque: 24 in-lb (2.71 N·m); branch screw torque: 18 in-lb (2.03 N·m). Protect the feed separately upstream.

IN +

positive · input

100 A

1

positive · output

30 A

2

positive · output

30 A

3

positive · output

30 A

4

positive · output

30 A

5

positive · output

30 A

6

positive · output

30 A

7

positive · output

30 A

8

positive · output

30 A

9

positive · output

30 A

10

positive · output

30 A

11

positive · output

30 A

12

positive · output

30 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Wire sizes and fuse ratings apply to the connected example, not a fixed cable size for this component. Set your actual equipment, current, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with BS 5029.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.