RTX 2000 12V / 9620001310

Dometic CoolAir RTX 2000 12V 9620001310 wiring diagram

Review how the Dometic CoolAir RTX 2000 12V 9620001310 connects, how it operates and which installation requirements apply to this model.

Open this example as a new project. Use your own parts and cable lengths to make the plan yours.

Connection and installation overview

The 12 V RTX uses separately protected main-power and voltage-monitor connections. Its cooling capacity is not its electrical input. Follow the model-specific four-wire installation and its 80 A main and 2 A monitoring protection.

The 12 V RTX uses separately protected main-power and voltage-monitor connections. Its cooling capacity is not its electrical input. Follow the model-specific four-wire installation and its 80 A main and 2 A monitoring protection.

Show sizes in mm²

Wiring diagram

How the RTX 2000 12V is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

See the field notes for this part’s connections and installation requirements.
Start a diagram with this part

Installation notes

Connections and installation requirements.

Guidance for this model, with sources linked beside the relevant advice.

Verified against the manufacturer's documentation (rev. 4445103796 — 2024-09-19, RTX 1000/2000 installation manual), checked 2026-10-01. Manufacturer documentation →

Which RTX 2000 is covered?

This is the 12 V unit, SKU 9620001310, as identified on Dometic's product page. The currently linked installation table, page 15, specifies 10–60 A and a 9–15 V operating range for RTX 2000 12 V. Older family instructions list 58 A; the catalog follows the newer 60 A limit. Cooling capacity is not electrical input power, and the SKU page and family table use different cooling-capacity figures, so no cooling wattage is inserted into the electrical budget.

Why are there four supply-related leads?

The wiring diagram and instructions, pages 5 and 11, separate the heavy power circuit from battery-voltage monitoring. The main red positive lead needs 80 A protection; its black return carries the operating current. The separate red monitoring lead needs 2 A protection, with its own black reference return. Both pairs must follow Dometic's diagram.

The catalog's `pos` and `neg` terminals are the power pair. `sense-pos` and `sense-neg` represent the monitoring pair and do not carry the compressor's 60 A. Their 2 A boundary identifies protection, not sensing consumption. A two-wire example omits part of the actual installation; do not join the monitoring lead into the heavy feed merely to simplify the drawing.

What does roof installation involve?

Use the mounting kit approved for the vehicle and confirm the roof opening, support, roof thickness and permitted mounting angle. The SKU installation prerequisites explain the roof and mounting checks. Keep service access and air paths clear and follow the seal and fastener sequence. Do not remove an emergency exit to install the unit.

How do setup and battery endurance interact?

The installer configuration, pages 12–13, includes the battery monitor; the 12 V factory undervoltage setting is 11.5 V. That setting protects operation, and does not replace a battery-specific discharge plan. The 60 A catalog value is an upper electrical load, so an hours-per-day budget at that value is conservative rather than a measured average. If the unit stops on low voltage, compare voltage at the battery and at the power terminals under load, then check the separate monitor wiring, fuses and connections.

Build it out

Connect it to the rest of your system.

Add RTX 2000 12V / 9620001310 to your diagram, then connect your batteries, chargers and loads. Crimp calculates cable sizes and checks the connections as you draw.

Every cable you draw there is sized against ABYC E-11, from the same tables as the reference on this page.

Technical reference

Specifications, terminals and supporting parts.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Nominal voltage
12 V
Compatible systems
12 V
Continuous draw
60 A

Supporting parts

  1. A lug or terminal to match each post on the part
  2. Strain relief and boots so nothing chafes or shorts
  3. Cable and fuses sized once the whole system is drawn

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

pos

positive · input

60 A

−

neg

negative · input

60 A

Voltage monitor +

sense-pos

signal · input

2 A

Voltage monitor −

sense-neg

signal · input

2 A

Method & provenance

Where the specifications and sizing come from.

Manufacturer specifications describe the equipment. Crimp calculates cable results from the circuit and assumptions you enter.

From the maker

What the catalog says

Manufacturer, model, ratings and which terminal does what come from the catalog. A newer revision, or the nameplate on the unit in your hand, can say something different — when it does, the nameplate wins.

ABYC E-11

What Crimp worked out

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The run length and the current above are what drive the result. Crimp doesn't know how warm your space gets; draw the cable inside an engine-bay zone on the canvas and it sizes for the heat.

Read how the sizing works

Next step

Plan your installation with RTX 2000 12V.

Open this example as a new project. Add your equipment and cable lengths, then review the sizing and checks for your setup.