Safe-T-Alert 35-742 wiring diagram

See the Safe-T-Alert 35-742 connection points and wiring example. Open the diagram in Crimp to add your equipment and plan the cables between them.

Open this example as a new project. Use your own parts and cable lengths to make the plan yours.

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

10 ft one way

12 V system

Wire
16 AWG · 1.5 mm²
Example fuse
1 A
Design current
0.1 A
Voltage drop
0.1%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Show sizes in mm²

Wiring diagram

How the 35-742 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Safe-T-Alert 35-742 wiring diagram, 16 AWG (1.5 mm²) positive feed protected by a 1 A fuse and a matching negative return between the 12 V battery bank and the unit.
Edit this wiring example

Installation notes

Connections and installation requirements.

Guidance for this model, with sources linked beside the relevant advice.

Verified against the manufacturer's documentation (rev. RV 35 Series installation and operating manual — ©2023), checked 2026-10-01. Manufacturer documentation →

Which alarm and what power does it need?

The 35-742 is the flush-mount member of Safe-T-Alert's RV 35-series propane/CO alarm family. The manual specifications, page 2, give 12 V nominal, ±15%, and 108 mA. The catalog keeps it as a continuous load, approximately 2.59 Ah/day. Use the correct variant and installation environment; this RV alarm is not an ignition-protected bilge device.

How should it be connected?

The installation instructions, page 1, identify red as the house-battery positive feed and black as return. Use 14–18 AWG wire and a properly fused circuit with no more than 15 A overcurrent protection. Fifteen amps is the allowed protection ceiling, not the alarm's current or a requirement to choose that large a fuse. The catalog's 0.108 A terminal envelope expresses normal demand rather than connector capacity.

Keep the supply energized while the vehicle is occupied. When replacing an older two-source alarm, the manual specifically warns against combining its two battery feeds: retain the intended supply and insulate the unused old wire as directed. Do not bridge house and starter batteries through the alarm wiring.

Where should it be installed?

Mount the alarm 4–20 in above the floor and follow the manual's exclusions, including staying at least 12 in from doors, windows and vents. Avoid dead-air spaces, hidden positions behind furniture and locations exposed to contamination or cleaners. A convenient cable route does not make an obstructed location suitable for gas detection.

What tests, alarms and replacement checks matter?

Test weekly and vacuum dust from the cover monthly. The operating instructions, page 2, distinguish the repeating four-beep CO pattern from the continuous-beep gas alarm. Respond to an alarm by following the evacuation and source-investigation instructions; disconnecting its power is not a way to establish safety. Use the test/silence control only as the manual permits.

Record installation date and replace the alarm five years after installation. If that date is unknown, the manual limits service to five years after manufacture. A powered green indicator does not override an expired service life or a fault indication.

Build it out

Connect it to the rest of your system.

Add 35-742 to your diagram, then connect your batteries, chargers and loads. Crimp calculates cable sizes and checks the connections as you draw.

Every cable you draw there is sized against ABYC E-11, from the same tables as the reference on this page.

Technical reference

Specifications, terminals and supporting parts.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Nominal voltage
12 V
Compatible systems
12 V
Continuous draw
0.1 A

Supporting parts

  1. 20 ft total of 16 AWG (1.5 mm²) marine cable
  2. Terminations for 16 AWG cable, matched to the equipment's screw terminals, leads or studs
  3. 1 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

pos

positive · input

0.108 A

−

neg

negative · input

0.108 A

Method & provenance

Where the specifications and sizing come from.

Manufacturer specifications describe the equipment. Crimp calculates cable results from the circuit and assumptions you enter.

From the maker

What the catalog says

Manufacturer, model, ratings and which terminal does what come from the catalog. A newer revision, or the nameplate on the unit in your hand, can say something different — when it does, the nameplate wins.

ABYC E-11

What Crimp worked out

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The run length and the current above are what drive the result. Crimp doesn't know how warm your space gets; draw the cable inside an engine-bay zone on the canvas and it sizes for the heat.

Read how the sizing works

Next step

Plan your installation with 35-742.

Open this example as a new project. Add your equipment and cable lengths, then review the sizing and checks for your setup.