Nature's Head Standard Composting Toilet wiring diagram

Standard separating toilet with continuously powered 12 V ventilation fan. Manual current is 0.07 A (1.68 Ah/day), with 2–5 A supply protection. The fan feed is the electrical load; the agitator is manual. Vent routing and access for removing both waste containers are essential.

Nominal voltage
12 V
Compatible systems
12 V
Continuous draw
0.1 A

Wiring diagram

How the Standard is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Nature's Head Standard Composting Toilet wiring example with 3 components: House bank, Fused DC distribution, Standard. 4 cable connections. Crossings are not junctions.Fused DC distribution 1 to Standard +: 16 AWG · 2 A fuse, 10 ft one way. Fused DC distribution 1 to Standard −: 16 AWG, 10 ft one way. House bank + to Fused DC distribution IN +: 16 AWG · 1 A fuse, 1.0 ft one way. House bank − to Fused DC distribution IN −: 16 AWG, 1.0 ft one wayFused DC distribution 1 to Standard +: 16 AWG · 2 A fuse, 10 ft one wayFused DC distribution 1 to Standard −: 16 AWG, 10 ft one wayHouse bank + to Fused DC distribution IN +: 16 AWG · 1 A fuse, 1.0 ft one wayHouse bank − to Fused DC distribution IN −: 16 AWG, 1.0 ft one way12 V 200 Ah house bankHouse bank++−−Blue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Nature's Head Standard Composting Toilet. The example uses a 2 A fuse, within Nature's Head's specified 2–5 A range. The 0.07 A load is the continuous ventilation fan; keep ventilation powered as directed and verify the actual run and polarity.Standard++−−16 AWG · 2 A fuse16 AWG16 AWG · 1 A fuse16 AWG
Nature's Head Standard Composting Toilet wiring example with 3 components: House bank, Fused DC distribution, Standard. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Cable labels are example values; use the equipment instructions and actual installation lengths.

The example uses a 2 A fuse, within Nature's Head's specified 2–5 A range. The 0.07 A load is the continuous ventilation fan; keep ventilation powered as directed and verify the actual run and polarity. Manufacturer installation manual

Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

10 ft one way

12 V system

Wire
16 AWG · 1.5 mm²
Example fuse
2 A
Design current
0.1 A
Voltage drop
0.0%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

The example uses a 2 A fuse, within Nature's Head's specified 2–5 A range. The 0.07 A load is the continuous ventilation fan; keep ventilation powered as directed and verify the actual run and polarity. Manufacturer installation manual

Show sizes in mm²

Supporting parts

  1. 20 ft total of 16 AWG (1.5 mm²) marine cable
  2. Terminations for 16 AWG cable, matched to the equipment's screw terminals, leads or studs
  3. 2 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Nature's Head User Guide 2025 download; ©2023 manual), checked 2026-10-01. Manufacturer documentation →

What is the electrical load?

The standard Nature's Head separating composting toilet uses a small 12 V ventilation fan. The electrical data, PDF page 14 / printed 12, gives 0.07 A, equivalent to 1.68 Ah per day with continuous operation. The catalog treats the fan as always on. The mixing handle is manual and adds no electrical demand.

That page also prints an instantaneous wattage inconsistent with its current and daily energy figures. The catalog retains the stated 0.07 A and does not copy that wattage typo into the power data. At 12 V, 0.07 A would be 0.84 W by calculation.

How should the fan be powered?

The wiring instructions, PDF page 13 / printed 11, call for 2–5 A circuit protection. A 2 A branch fuse is within this published range. Use the supplied fused lead when connecting directly to a battery and keep polarity correct. A mains outlet requires the appropriate 12 V adapter; never connect the fan directly to mains. The 0.07 A terminal envelope represents operating demand, not the upstream fuse or a connector rating.

What does installation need besides power?

The ventilation and mounting instructions, PDF pages 4–7, route ventilation to an exterior sidewall or roof vent, with appropriate weather protection. A van floor vent is not the specified arrangement. Keep the vent run within the manual's 20 ft limit, support any extensions and avoid crushing the hose. Leave approximately 1.5 in behind the toilet for tilting the top and 2 in at the side needed for sliding removal. Check access with both containers actually removed before fixing the base.

How should it be used and checked?

Prepare the compost medium damp, not saturated, and keep liquids separated as the guide describes. Run the fan continuously during use and the associated drying period. For an absence of more than about a week, follow the guide's storage procedure; excessive drying can harden the contents. If airflow stops, check the fuse, polarity, plug and hose path. The fan must face the intended direction, and overtightened mounting screws can bind it. Keep cleaning liquids out of the fan and electrical connections, and empty each container according to the manual and local disposal arrangements.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Standard separating toilet with continuously powered 12 V ventilation fan. Manual current is 0.07 A (1.68 Ah/day), with 2–5 A supply protection. The fan feed is the electrical load; the agitator is manual. Vent routing and access for removing both waste containers are essential.

Nominal voltage
12 V
Compatible systems
12 V
Continuous draw
0.1 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · input

0.07 A

−

negative · input

0.07 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Standard.