Axiom+ 9 takes 12 V nominal, with an 8–16 V input range. It is not a direct 24 V load. On a 24 V vessel, use a correctly sized converter and its required protection. The installation manual specifies a 7 A inline fuse or 7 A thermal breaker for the display.
Connect the supplied cable's red positive and black negative, and terminate its drain conductor as instructed for the vessel's RF ground arrangement. Keep fuse access and cable support after mounting. The combined power/NMEA 2000 harness does not mean the network supplies the screen or that the screen supplies the backbone; both power arrangements need to be understood separately.
The exact chartplotter specification is 8.95 W maximum. The catalog's approximately 0.75 A is 8.95 W / 12 V, a nominal-voltage calculation. It is not the 11.98 W RV-with-transducer rating. Terminal limits are protection-based planning bounds, and no unverified startup current is assigned.