Brown is the automatic positive supply, brown/white is the manual override positive, and black is negative. Connect the control arrangement using the manual's three-position panel or separate automatic/manual diagram. Automatic protection should remain available when the ordinary cabin circuits are switched off. If manual override is not fitted, insulate its unused lead individually; do not leave exposed copper in the bilge.
Use the specified 7.5 A fuse. Rule explicitly discourages circuit breakers for these pumps. The catalog's 4.8 A is the published running draw at 13.6 V; the same table gives 3.8 A at 12 V. Neither number is an inrush measurement. The three canvas terminals preserve the distinct leads, but the planner cannot simulate the internal water sensor or switch logic. A connected automatic lead does not mean the motor runs all day.