Load

Rule Rule-Mate 1100 RM1100B 12V connections

Review the Rule Rule-Mate 1100 RM1100B 12V connections, setup and installation requirements. This overview does not calculate cable or protection sizes.

Nominal voltage
12 V
Compatible systems
12 V
Continuous draw
4.8 A

Connection overview

Rule-Mate 1100 connections.

See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.

Rule Rule-Mate 1100 RM1100B 12V connection overview with 3 components: Rule-Mate 1100, 12 V House battery, Bilge auto / manual panel. 5 cable connections. Crossings are not junctions.12 V House battery + to Bilge auto / manual panel +: 7.5 A specified fuse. 12 V House battery − to Bilge auto / manual panel −. Bilge auto / manual panel Unswitched auto to Rule-Mate 1100 Auto + (brown). Bilge auto / manual panel Manual switch to Rule-Mate 1100 Manual + (brown/white). Bilge auto / manual panel Common − to Rule-Mate 1100 − (black)12 V House battery + to Bilge auto / manual panel +: 7.5 A specified fuse12 V House battery − to Bilge auto / manual panel −Bilge auto / manual panel Unswitched auto to Rule-Mate 1100 Auto + (brown)Bilge auto / manual panel Manual switch to Rule-Mate 1100 Manual + (brown/white)Bilge auto / manual panel Common − to Rule-Mate 1100 − (black)Rule Rule-Mate 1100 RM1100B 12V. The Rule-Mate has separate automatic and manual positive feeds with a shared negative. Keep the automatic circuit available when unattended, and follow Rule's switching and fuse arrangement. A single switched battery lead does not describe the complete installation. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.Rule-Mate 1100Auto + (brown)+Manual + (brown/white)− (black)− (black)12 V House battery. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.12 V House battery++−−Bilge auto / manual panel. The automatic feed remains available when the house panel is off; the manual feed has its own operating switch. Both are protected by the specified 7.5 A fuse. Switching logic is illustrative; inspect the pump diagram.Bilge auto / manualpanel++−−Unswitched auto+Manual switchCommon −Common −7.5 A specified fuse
Rule Rule-Mate 1100 RM1100B 12V connection overview with 3 components: Rule-Mate 1100, 12 V House battery, Bilge auto / manual panel. 5 cable connections. Crossings are not junctions.The Rule-Mate has separate automatic and manual positive feeds with a shared negative. Keep the automatic circuit available when unattended, and follow Rule's switching and fuse arrangement. A single switched battery lead does not describe the complete installation. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.
Edit this connection overview

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 950-0535 Rev E, 07/2024), checked 2026-10-01. Manufacturer documentation →

Which pump this is

RM1100B is the 12 V Rule-Mate 1100 with an integrated water sensor. The 1100 GPH name describes open discharge: the manual shows 806 GPH at 1 m head and 554 GPH at 2 m. Hose height and resistance therefore matter before choosing it for a particular bilge. This is a bilge-water pump, not a fuel-transfer pump.

Keep automatic and manual power distinct

Brown is the automatic positive supply, brown/white is the manual override positive, and black is negative. Connect the control arrangement using the manual's three-position panel or separate automatic/manual diagram. Automatic protection should remain available when the ordinary cabin circuits are switched off. If manual override is not fitted, insulate its unused lead individually; do not leave exposed copper in the bilge.

Use the specified 7.5 A fuse. Rule explicitly discourages circuit breakers for these pumps. The catalog's 4.8 A is the published running draw at 13.6 V; the same table gives 3.8 A at 12 V. Neither number is an inrush measurement. The three canvas terminals preserve the distinct leads, but the planner cannot simulate the internal water sensor or switch logic. A connected automatic lead does not mean the motor runs all day.

Install the discharge and cable route

Secure the strainer base where water collects, with access to release and clean it. Check material thickness before drilling. Use smooth flexible hose and avoid kinks, unnecessary height and low pockets; rigid pipe can stress the pump outlet. Arrange the outlet and any vented loop for the vessel's heeled waterline. A check valve does not provide anti-siphon protection.

The supplied leads are 16 AWG tinned wire. Size extensions for the complete positive-and-negative circuit and protect sealed joints above bilge water. The manual's distance-conversion column has inconsistencies; establish the real route length instead of trusting a converted column blindly. Terminal limits in the catalog are protection-based planning bounds, not independently published connector ratings.

Prove both operating modes

Introduce clean water into the bilge and confirm automatic start near 63.5 mm depth, discharge outside the boat, and stopping near 16 mm. Test manual override separately, then restore automatic mode. Check voltage at the running pump: Rule specifies at least 10.5 V there. A motor that turns with little discharge calls for inspection of the strainer, hose and discharge head, not a larger fuse. Debris can also trigger the sensor's fallback cycling; clean and retest before accepting that behavior as normal.

Manual and evidence

Rule-Mate 500–1100 manual: PDF pp. 3–7 cover the exact RM1100B ratings, sensing behavior, three-wire circuits and installation. The downloaded PDF and its SHA-256 are recorded in the marine research ledger.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Automatic 1100 GPH bilge pump. Draw is 3.8 A at 12 V or 4.8 A at 13.6 V; the catalog uses the higher running value. Requires a 7.5 A fuse. Brown automatic and brown/white manual feeds are separate; retain automatic power when the house panel is off. Terminal limits are planning bounds from specified protection.

Nominal voltage
12 V
Compatible systems
12 V
Continuous draw
4.8 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

Auto + (brown)

positive · input

7.5 A

Manual + (brown/white)

positive · input

7.5 A

− (black)

negative · input

7.5 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Connection overview. This diagram explains the connection arrangement; it does not calculate cable sizes or protection for the installation. Follow the manufacturer’s complete wiring and protection instructions.

Read how the sizing works

Next step

Plan your installation with Rule-Mate 1100.

Open the connection overview as a new project, or add this component to a diagram you already have.

Free for up to 10 equipment components, with no account needed. Cables, busbars and fuse hardware do not count toward the limit. Your drawing saves in this browser. File exports are included with Crimp Pro.