Load

Thetford C223-CS connections

Review the Thetford C223-CS connections, setup and installation requirements. This overview does not calculate cable or protection sizes.

Nominal voltage
12 V
Compatible systems
12 V

Connection overview

C223-CS connections.

See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.

Thetford C223-CS connection overview with 4 components: C223-CS, Protected bathroom circuits, 12 V House battery, External flush-pump circuit. 8 cable connections. Crossings are not junctions.12 V House battery + to Protected bathroom circuits +. 12 V House battery − to Protected bathroom circuits −. Protected bathroom circuits + to C223-CS +. Protected bathroom circuits − to C223-CS −. Protected bathroom circuits + to External flush-pump circuit +. Protected bathroom circuits − to External flush-pump circuit −. C223-CS Pump relay COM to External flush-pump circuit Relay COM: Dry-contact COM. C223-CS Pump relay NO to External flush-pump circuit Relay NO: Dry-contact NO12 V House battery + to Protected bathroom circuits +12 V House battery − to Protected bathroom circuits −Protected bathroom circuits + to C223-CS +Protected bathroom circuits − to C223-CS −Protected bathroom circuits + to External flush-pump circuit +Protected bathroom circuits − to External flush-pump circuit −C223-CS Pump relay COM to External flush-pump circuit Relay COM: Dry-contact COMC223-CS Pump relay NO to External flush-pump circuit Relay NO: Dry-contact NOThetford C223-CS. The C223-CS has a low-voltage power connection and separate dry contacts for an external pump. The source must supply 3 A, but that capability is not a measured operating or startup draw. Follow the toilet and pump wiring diagrams together. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.C223-CS++−−Pump relay COMPump relay NOProtected bathroom circuits. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.Protected bathroomcircuits++−−++−−12 V House battery. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.12 V House battery++−−External flush-pump circuit. Reference external pump circuit includes its separately selected protection and any necessary interface relay. The toilet's contacts are dry contacts, maximum 6 A; they do not supply pump power. Actual pump current is not assumed.External flush-pumpcircuit++−−Relay COMRelay COMRelay NODry-contact COMDry-contact NO
Thetford C223-CS connection overview with 4 components: C223-CS, Protected bathroom circuits, 12 V House battery, External flush-pump circuit. 8 cable connections. Crossings are not junctions.The C223-CS has a low-voltage power connection and separate dry contacts for an external pump. The source must supply 3 A, but that capability is not a measured operating or startup draw. Follow the toilet and pump wiring diagrams together. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.
Edit this connection overview

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. C220-series installation manual, manufacturer download January 2025), checked 2026-10-01. Manufacturer documentation →

Which C220 variant is covered?

The C223-CS cassette toilet flushes from the vehicle's water system. Do not substitute the C222 variant's integrated flush-water arrangements. The C220 installation manual covers several variants, so follow the columns and drawings marked for the C223-CS throughout. The fresh-water pump is a separate electrical load, even when the toilet operates its control relay.

What are the electrical connections?

The electrical drawing, page 23, specifies a 10–15 V supply capable of delivering 3 A. This is a source-capability requirement, not a measured continuous current; the catalog therefore leaves actual operating current and surge unset. Red is supply positive and black is return, shown as positions 5A and 5B in the manual's connector drawing.

The separate grey and purple wires are the external pump-relay contacts: grey NO at 4A and purple COM at 4B. Their maximum contact load is 6 A. They are shown as control terminals in the catalog, not as another battery input, and the model does not simulate the relay's switching. Do not place a pump whose load exceeds that rating directly through these contacts.

How should the supply and pump be planned?

The manual identifies the red/black harness as 0.5 mm² and grey/purple as 0.75 mm². Those are the appliance's harness sizes, not an unconditional prescription for a long battery run. The reviewed page does not state an external branch-fuse rating. Protect each installation feed for its conductor and equipment requirements and account separately for the pump's startup and operating demand. The 3 A catalog power-terminal boundary represents the stated supply capability; it is not a verified connector ampacity.

What must be accessible and tested?

Use the installation sequence and final checks, pages 24–25, to verify access to the waste cassette, the service door, the water connection and the electrical connector. Test flushing, the waste-level indication, leaks and unobstructed removal and insertion of the waste tank. Seal the exterior service-door installation correctly and confirm winter draining for the complete water system. If flushing fails, check supply at the toilet, the pump circuit and relay wiring separately rather than treating the toilet and pump as one load.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Cassette toilet supplied from the vehicle fresh-water system. The manual requires a 10–15 V source capable of 3 A; it does not specify actual operating current. Separate grey/purple flush-pump relay contacts are limited to 6 A. The pump is a separate load. The 3 A power-terminal value is a source-capability planning boundary.

Nominal voltage
12 V
Compatible systems
12 V

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · input

3 A

−

negative · input

3 A

Pump relay COM

signal · input

6 A

Pump relay NO

signal · input

6 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Connection overview. This diagram explains the connection arrangement; it does not calculate cable sizes or protection for the installation. Follow the manufacturer’s complete wiring and protection instructions.

Read how the sizing works

Next step

Plan your installation with C223-CS.

Open the connection overview as a new project, or add this component to a diagram you already have.

Free for up to 10 equipment components, with no account needed. Cables, busbars and fuse hardware do not count toward the limit. Your drawing saves in this browser. File exports are included with Crimp Pro.