ChargeMaster Plus 12/50-3 (44310505)

Mastervolt ChargeMaster Plus 12/50-3 wiring diagram

12V charger with three positive outputs sharing 50A total and a common negative. Any output may receive the full available current; the unit does not provide 50A simultaneously to each bank. Accepts 80–275VAC and supports standalone, MasterBus or CZone operation.

Nominal voltage
12 V
Compatible systems
12 V
Rated output
50 A

Wiring diagram

How the ChargeMaster Plus 50A is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Mastervolt ChargeMaster Plus 12/50-3 wiring example with 3 components: ChargeMaster Plus 50A, Battery disconnect, House bank. 3 cable connections. Crossings are not junctions.ChargeMaster Plus 50A DC 1 + to Battery disconnect A: 4 AWG · 60 A fuse, 10 ft one way. ChargeMaster Plus 50A COMMON − to House bank −: 4 AWG, 10 ft one way. Battery disconnect B to House bank +: 4 AWG · 60 A fuse, 1.0 ft one wayChargeMaster Plus 50A DC 1 + to Battery disconnect A: 4 AWG · 60 A fuse, 10 ft one wayChargeMaster Plus 50A COMMON − to House bank −: 4 AWG, 10 ft one wayBattery disconnect B to House bank +: 4 AWG · 60 A fuse, 1.0 ft one wayMastervolt ChargeMaster Plus 12/50-3. The example connects one charger output to one placeholder house bank using 25 mm² over 3.048 m and a 60 A battery-positive fuse. The three outputs share the charger's 50 A total; adding banks does not provide 50 A to each simultaneously. Other outputs, AC supply, protective earth and communications remain for installation planning against the full manual.ChargeMaster Plus 50ADC 1 +DC 1 +COMMON −COMMON −Main Battery SwitchBattery disconnectAB12 V 200 Ah AGM placeholder bank. Example bank only: select the correct charger profile and confirm the actual battery's capacity, charging-current acceptance, voltage and temperature limits. Placeholder current limits are not manufacturer battery specifications.House bank++−−4 AWG · 60 A fuse4 AWG4 AWG · 60 A fuse
Mastervolt ChargeMaster Plus 12/50-3 wiring example with 3 components: ChargeMaster Plus 50A, Battery disconnect, House bank. 3 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Cable labels are example values; use the equipment instructions and actual installation lengths.

The example connects one charger output to one placeholder house bank using 25 mm² over 3.048 m and a 60 A battery-positive fuse. The three outputs share the charger's 50 A total; adding banks does not provide 50 A to each simultaneously. Other outputs, AC supply, protective earth and communications remain for installation planning against the full manual. Manufacturer installation manual

Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

10 ft one way

12 V system

Wire
4 AWG · 25 mm²
Example fuse
60 A
Design current
50 A
Voltage drop
1.8%

Sized against ABYC E-11. The design current is the unit's rated output. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

The example connects one charger output to one placeholder house bank using 25 mm² over 3.048 m and a 60 A battery-positive fuse. The three outputs share the charger's 50 A total; adding banks does not provide 50 A to each simultaneously. Other outputs, AC supply, protective earth and communications remain for installation planning against the full manual. Manufacturer installation manual

Show sizes in mm²

Supporting parts

  1. 20 ft total of 4 AWG (25 mm²) marine cable
  2. Terminations for 4 AWG cable, matched to the equipment's screw terminals, leads or studs
  3. 60 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 10000016594/05 archived; current manufacturer revision /06 cross-checked online), checked 2026-10-01. Manufacturer documentation →

What does “12/50-3” mean?

The ChargeMaster Plus 44310505 has three positive battery outputs and a common negative. 50 A is the shared total: one output can receive the full available current, but three connected banks do not create 150 A. This is the Plus model, not the older ChargeMaster.

How are the cables and fuses connected?

Connect DC 1/2/3 positives to the respective banks, each with protection at its battery, and the common negative to the system return/shunt side. Manual pages 8–9 specify 60 A DC fuses, 16 mm² below 3 m, and 25 mm² for 3–5 m. Do not use the chassis as the negative conductor. Main DC connections tighten to 4.9–5.4 Nm.

The AC input requires the appropriate line/neutral or split-phase wiring, protective earth and an accessible disconnect. A DC-negative cable does not replace protective earth.

What must be set before charging?

Select the battery profile with the documented DIP-switch/network procedure. Confirm lithium voltage limits with the battery maker; network connectivity alone does not establish BMS shutdown compatibility. When shore capacity is limited, configure AC current control to fit the available supply rather than reducing cable protection arbitrarily.

How should it be mounted and checked?

Mount vertically with cables down, clear cooling paths and protection from water, salt and battery gases. Output derates in heat. Verify each bank’s voltage and charging behavior separately. The archived manual is revision /05; current revision /06 is also linked for later installation changes. Automatic current sharing is not modeled as a guarantee of 50 A to every drawn branch.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

12V charger with three positive outputs sharing 50A total and a common negative. Any output may receive the full available current; the unit does not provide 50A simultaneously to each bank. Accepts 80–275VAC and supports standalone, MasterBus or CZone operation.

Nominal voltage
12 V
Compatible systems
12 V
Rated output
50 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

AC L

neutral · input

7.1 A

AC N

neutral · input

7.1 A

AC PE

ground · input

7.1 A

DC 1 +

positive · output

50 A

DC 2 +

positive · output

50 A

DC 3 +

positive · output

50 A

COMMON −

negative · output

50 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with ChargeMaster Plus 50A.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Free for up to 10 equipment components, with no account needed. Cables, busbars and fuse hardware do not count toward the limit. Your drawing saves in this browser. File exports are included with Crimp Pro.