Crimp
Component folio · Charger · Victron

Victron Orion XS 12/12-50

Model Orion XS 12/12-50A

Non-isolated 50A DC-DC charger with high efficiency.

Open in Crimp →
Victron Orion XS 12/12-50
Victron Orion XS 12/12-50 · 4 terminals
01 — Wiring diagram

How the Orion XS 50A is wired

Victron Orion XS 12/12-50 wiring diagram WIRING DIAGRAM Victron Orion XS 12/12-50 wiring diagram 12 V battery bank Charged by this unit Orion XS 50A Victron · Orion XS 12/12-50A 70 A 6 AWG (16 mm²) → OUT + 6 AWG (16 mm²) → OUT − 10 ft one way IN + IN − crimp.studio 50 A · 2.8% drop · ABYC E-11
Victron Orion XS 12/12-50 wiring diagram, 6 AWG (16 mm²) positive feed protected by a 70 A fuse and a matching negative return between the 12 V battery bank and the unit, plus IN +, IN −.

The run drawn here is the 10 ft reference run sized below. Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. Confirm your own run length, routing and terminations before ordering — open this part in the designer to size it against your actual system.

02 — Reference run

What size cable and fuse does the Orion XS 50A need?

Conductor6 AWG16 mm²
Fuse70 Apositive run
Voltage drop2.8%10 ft one way
Design current50 A12 V system

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The design current is the unit's rated output. The Crimp engine applies its ordinary continuous-load headroom, voltage-drop budget, terminal clamp, and standard fuse ladder. The 10 ft one-way run is a stated reference, not a universal installation prescription.

03 — Catalog specification

Victron Orion XS 12/12-50 specifications and terminal map

Rated output
50 A
Typical charge current
48 A

Terminal map

TerminalPolarityDirectionRating
IN +positiveinput70 A
IN −negativeinput70 A
OUT +positiveoutput50 A
OUT −negativeoutput50 A
04 — Supporting parts

What else you need to wire the Orion XS 50A

  • 20 ft total of 6 AWG (16 mm²) marine cable
  • Four 6 AWG cable lugs matched to the equipment studs
  • 70 A fuse and holder on the positive run
  • Heat-shrink, strain relief, and terminal boots sized to the cable

Start from this part

Open the canvas with the Orion XS 50A already placed, then wire the rest of the system around it. Nothing to install and no sign-up — the project is saved in this browser, and you can download the file whenever you want it.

Open the canvas →

05 — Field notes

Installation notes from the field

What it does

Charges a house battery from the vehicle's alternator circuit at up to 50 A, with input and output current limits you set in VictronConnect. It is non-isolated (input and output share a negative), and at around 98.5% efficiency it runs without a fan.

Wiring it

The input side comes from the starter battery or alternator feed; the output side goes to the house bank. Both legs carry real current, so both get sized and fused — not just the output. Engine-run detection works from the input voltage, so no ignition-trigger wire is required in the common case.

What people get wrong

Sizing the input wiring for the 50 A output. A DC-DC charger is not lossless and its input voltage can sit below its output voltage while charging, so the input side draws more than 50 A — around 60 A at full load. Victron's manual calls for a 60–70 A fuse on the input; an input leg wired at 50 A runs hot and nuisance-blows.

Supporting parts

  • Fuses on both legs, at the battery end of each run — the input per the manual's 60–70 A recommendation
  • Cable lugs matched to the unit's terminals and the fuse holders
  • A negative return sized like the positive runs — non-isolated does not mean current-free

Verified against the manufacturer's datasheet, checked 2026-08-01. Manufacturer datasheet →

06 — Method & provenance

What is known, assumed, and computed.

Catalog profile

The manufacturer, model, ratings and terminal map are maintained as planning data in Crimp's component catalog. Confirm the current manufacturer manual, exact revision and installed nameplate before ordering or wiring.

Engine reference

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The published conductor, fuse and voltage-drop result uses the visible reference length and current basis; it is not a universal installation prescription.

Read the complete methodology →
07 — Related components

Alternatives to the Orion XS 50A

Browse all charger profiles →