Distribution

Leviton GFTR2-MW GFCI Receptacle 20A 125V connections

Review the Leviton GFTR2-MW GFCI Receptacle 20A 125V catalog ratings, AC connection points and installation notes, then add the part to your Crimp diagram.

Connection overview

GFCI 20A connections.

See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.

Leviton GFTR2-MW GFCI Receptacle 20A 125V connection overview with 7 components: Shore 30A, ELCI breaker 30A 120V, 120V panel, GFCI 20A, 120V appliance, 120V socket, 120V appliance. 18 cable connections. Crossings are not junctions.Shore 30A AC L to ELCI breaker 30A 120V LINE L. Shore 30A AC N to ELCI breaker 30A 120V LINE N. Shore 30A AC ⏚ to ELCI breaker 30A 120V EARTH IN. ELCI breaker 30A 120V LOAD L to 120V panel MAIN L. ELCI breaker 30A 120V LOAD N to 120V panel MAIN N. ELCI breaker 30A 120V EARTH OUT to 120V panel MAIN PE. 120V panel BRANCH 1 L to GFCI 20A LINE L. 120V panel BRANCH 1 N to GFCI 20A LINE N. 120V panel BRANCH 1 PE to GFCI 20A GROUND / PLUG PE. GFCI 20A PLUG L to 120V appliance SUPPLY L. GFCI 20A PLUG N to 120V appliance SUPPLY N. GFCI 20A GROUND / PLUG PE to 120V appliance SUPPLY PE. GFCI 20A LOAD L to 120V socket WIRING L. GFCI 20A LOAD N to 120V socket WIRING N. GFCI 20A GROUND / PLUG PE to 120V socket WIRING PE. 120V socket PLUG L to 120V appliance SUPPLY L. 120V socket PLUG N to 120V appliance SUPPLY N. 120V socket PLUG PE to 120V appliance SUPPLY PEShore 30A AC L to ELCI breaker 30A 120V LINE LShore 30A AC N to ELCI breaker 30A 120V LINE NShore 30A AC ⏚ to ELCI breaker 30A 120V EARTH INELCI breaker 30A 120V LOAD L to 120V panel MAIN LELCI breaker 30A 120V LOAD N to 120V panel MAIN NELCI breaker 30A 120V EARTH OUT to 120V panel MAIN PE120V panel BRANCH 1 L to GFCI 20A LINE L120V panel BRANCH 1 N to GFCI 20A LINE N120V panel BRANCH 1 PE to GFCI 20A GROUND / PLUG PEGFCI 20A PLUG L to 120V appliance SUPPLY LGFCI 20A PLUG N to 120V appliance SUPPLY NGFCI 20A GROUND / PLUG PE to 120V appliance SUPPLY PEGFCI 20A LOAD L to 120V socket WIRING LGFCI 20A LOAD N to 120V socket WIRING NGFCI 20A GROUND / PLUG PE to 120V socket WIRING PE120V socket PLUG L to 120V appliance SUPPLY L120V socket PLUG N to 120V appliance SUPPLY N120V socket PLUG PE to 120V appliance SUPPLY PEShore Power 120V/30A. Shore supply boundary. The upstream pedestal, shore lead, earthing system and source protection require separate verification.Shore 30AAC LAC NAC ⏚Blue Sea 8100 AC ELCI Main Circuit Breaker Panel 30A 120V. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example. Generic panel, socket and selector ratings are declared design choices, not a verified installed product. No automatic trip time, fault current, leakage operation or installation compliance is certified. Confirm each source's protection and neutral/earth arrangement.ELCI breaker 30A 120VLINE LLINE LLINE NEARTH INEARTH INLOAD LLOAD LLOAD NEARTH OUTEARTH OUTAC Distribution Panel 120V 30A · 3 Branches. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example. Generic panel, socket and selector ratings are declared design choices, not a verified installed product. No automatic trip time, fault current, leakage operation or installation compliance is certified. Confirm each source's protection and neutral/earth arrangement.120V panelMAIN LMAIN LMAIN NMAIN PEMAIN PEBRANCH 1 LBRANCH 1 LBRANCH 1 NBRANCH 1 NBRANCH 1 PEBRANCH 1 PELeviton GFTR2-MW GFCI Receptacle 20A 125V. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example. Generic panel, socket and selector ratings are declared design choices, not a verified installed product. No automatic trip time, fault current, leakage operation or installation compliance is certified. Confirm each source's protection and neutral/earth arrangement.GFCI 20ALINE LLINE LLINE NGROUND / PLUG PELOAD LLOAD LLOAD NLOAD NPLUG LPLUG LPLUG NPLUG NAC Appliance 120V 500W. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example. Generic panel, socket and selector ratings are declared design choices, not a verified installed product. No automatic trip time, fault current, leakage operation or installation compliance is certified. Confirm each source's protection and neutral/earth arrangement.120V applianceSUPPLY LSUPPLY LSUPPLY NSUPPLY PESUPPLY PEAC Socket 120V 15A. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example. Generic panel, socket and selector ratings are declared design choices, not a verified installed product. No automatic trip time, fault current, leakage operation or installation compliance is certified. Confirm each source's protection and neutral/earth arrangement.120V socketWIRING LWIRING LWIRING NWIRING PEWIRING PEPLUG LPLUG LPLUG NPLUG PEPLUG PEAC Appliance 120V 500W. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example. Generic panel, socket and selector ratings are declared design choices, not a verified installed product. No automatic trip time, fault current, leakage operation or installation compliance is certified. Confirm each source's protection and neutral/earth arrangement.120V applianceSUPPLY LSUPPLY LSUPPLY NSUPPLY PESUPPLY PE
Leviton GFTR2-MW GFCI Receptacle 20A 125V connection overview with 7 components: Shore 30A, ELCI breaker 30A 120V, 120V panel, GFCI 20A, 120V appliance, 120V socket, 120V appliance. 18 cable connections. Crossings are not junctions.Common shore-power arrangement with separate line, neutral and protective earth. Protection blocks represent the complete main/branch protection arrangement, not individually sized breakers. Follow the applicable mains installation and bonding instructions. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.
Edit this connection overview

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. PK-93792-10-00-2B AR0088; product specifications), checked 2026-10-20. Manufacturer documentation →

Which receptacle is this?

Leviton GFTR2-MW is a tamper-resistant GFCI receptacle rated 20 A / 125 V, including 20 A feed-through, for nominal 120 V circuits. Its Class A leakage threshold is 5 mA ±1 mA. Confirm the installed environment and product variant.

What do LINE, LOAD and PLUG mean?

The installation sheet distinguishes incoming LINE from protected downstream LOAD wiring. PLUG marks the receptacle face in this diagram. The common ground connection remains separate from the switching contacts.

What does the example check?

The drawing keeps both current-carrying conductors paired through the device and preserves earth. It includes upstream branch overcurrent protection. Reset and Tripped change contacts manually; leakage sensing, reset interlocks, automatic trip times and physical commissioning tests are not simulated.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Leviton GFTR2-MW 20 A / 125 V GFCI receptacle for nominal 120 V circuits, with Class A 5 mA ±1 mA leakage response. LINE is the supply; LOAD is protected downstream wiring; PLUG represents the receptacle face. Separate branch overcurrent protection is required. Only manual contact states are modeled.

The map identifies line, neutral and protective-earth connections. This page does not calculate an AC cable size or protection rating.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

LINE L

neutral · input

20 A

LINE N

neutral · input

20 A

GROUND / PLUG PE

ground · bidi

20 A

LOAD L

neutral · output

20 A

LOAD N

neutral · output

20 A

PLUG L

neutral · output

20 A

PLUG N

neutral · output

20 A
Sources and connection guidance

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

AC planning boundary. The drawing identifies conductors and connection points; supported switching states show contact continuity only. Crimp does not calculate AC load flow or verify fault protection, leakage trips, source isolation or grounding. This overview does not calculate cable sizes or validate protective devices. Follow the complete manufacturer installation instructions.

Read about the DC sizing method and its limits

Next step

Plan your installation with GFCI 20A.

Open the connection overview as a new project, or add this component to a diagram you already have.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.