Distribution

BEP 701-MD Motorised Battery Switch connections

Review the BEP 701-MD Motorised Battery Switch connections, setup and installation requirements. This overview does not calculate cable or protection sizes.

Compatible systems
12 V / 24 V

Connection overview

701-MD connections.

See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.

BEP 701-MD Motorised Battery Switch connection overview with 1 components: 701-MD. 0 cable connections. Crossings are not junctions.BEP 701-MD Motorised Battery Switch. The motorized switch needs its battery-negative control lead and the prescribed remote/indicator wiring in addition to its two main studs. Size the switched power path from its actual loads and charging sources; 275 A is a contact rating, not operating current. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.701-MD
BEP 701-MD Motorised Battery Switch connection overview with 1 components: 701-MD. 0 cable connections. Crossings are not junctions.The motorized switch needs its battery-negative control lead and the prescribed remote/indicator wiring in addition to its two main studs. Size the switched power path from its actual loads and charging sources; 275 A is a contact rating, not operating current. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.
Edit this connection overview

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. INST-701-MD-V4 plus BEP three-pin Deutsch wiring drawing; manufacturer-authored mirrors), checked 2026-10-01. Manufacturer documentation →

A motorized switch with manual override

The original 701-MD switches a battery's main positive conductor and is rated 275 A continuous. Its 455 A intermittent and 1,250 A cranking figures do not have usable time windows in this source, so they are not continuous design limits. This record is the standard 701-MD, not the voltage-sensitive MDVS or other remote-control variants. Remote operation requires the manual knob in the Auto Off position. See ratings, PDF p. 2.

Keep battery input and load output correct

Connect battery positive to the stud marked INPUT and the protected load circuit to OUTPUT. Although the contact carries current in either direction, the powered actuator arrangement depends on correct input orientation. Both large studs are 10 mm. Provide strain relief; the manual recommends 50 mm² cable and allows 70 mm² only as an absolute maximum with appropriate support. Choose the main fuse for the conductor and actual downstream duty, not automatically at 275 A.

Wire the three-pin remote connector

The Deutsch drawing identifies pin 1 red as the LED output, pin 2 green as the switch command, and pin 3 black as control negative. The remote switch grounds the green command; the red lead drives the indicator shown. Take the black negative from the same battery that this switch isolates, with only one negative supply to each unit. Mixing banks here can cause erratic operation. See rear view and remote wiring, PDF p. 1.

Test remote and local control

First check that manual On and Off operate the main circuit. In Auto Off, exercise the remote switch and compare the indicator with continuity or load voltage. Automatic operation needs 8–30 V; a rapid status indication can point to supply outside that range. Off-state standby draw is documented as 15 mA, not zero, so include it when evaluating long storage. A manual override changes the contact state independently of the remote command. See operation and indications, PDF p. 3.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

275 A continuous remote battery switch with manual override. Input stud must face the battery; the control negative must come from that same battery.

Compatible systems
12 V / 24 V

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

BATTERY INPUT

positive · bidi

275 A

LOAD OUTPUT

positive · bidi

275 A

PIN 1 RED LED

signal · bidi

—

PIN 2 GREEN COMMAND

signal · bidi

—

PIN 3 BLACK −

negative · input

—

A dash means a current rating is not specified here.

Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Connection overview. This diagram explains the connection arrangement; it does not calculate cable sizes or protection for the installation. Follow the manufacturer’s complete wiring and protection instructions.

Read how the sizing works