Parallax Power Supply
Parallax 088-0001-001 DC Fuse Board · 15 Circuits wiring diagram
Parallax 088-0001-001 positive-only DC board, identified by its printed label: nominal 12 V, 100 A maximum total, fifteen ATC fuse circuits. Maximum branch fuse: 30 A on circuits 1–2 and 20 A on circuits 3–15; these are limits, not installed fuse values. Three positive lugs are common and unfused; an output from a lug needs separate protection. Draw negative returns on a separate bus. No converter is included. Verify the installed assembly label: the older 5300 guide shows an 85 A / 20 A revision, so this board does not establish a 100 A rating for every 5355.
- Compatible systems
- 12 V
Wiring diagram
How the 088-0001-001 · 15 circuits is wired.
Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.
Cable sizing for this example
Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.
Cable sizes depend on the connected equipment, current and cable lengths. Add those details in Crimp to size each run.
Technical reference
Specifications and terminal map.
Check the model, ratings and connection points against your own unit before choosing installation hardware.
Catalog specification
Parallax 088-0001-001 positive-only DC board, identified by its printed label: nominal 12 V, 100 A maximum total, fifteen ATC fuse circuits. Maximum branch fuse: 30 A on circuits 1–2 and 20 A on circuits 3–15; these are limits, not installed fuse values. Three positive lugs are common and unfused; an output from a lug needs separate protection. Draw negative returns on a separate bus. No converter is included. Verify the installed assembly label: the older 5300 guide shows an 85 A / 20 A revision, so this board does not establish a 100 A rating for every 5355.
- Compatible systems
- 12 V
Terminal map
Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.
LUG 1 +
positive · input
LUG 2 +
positive · input
LUG 3 +
positive · input
FUSE 1
positive · output
FUSE 2
positive · output
FUSE 3
positive · output
FUSE 4
positive · output
FUSE 5
positive · output
FUSE 6
positive · output
FUSE 7
positive · output
FUSE 8
positive · output
FUSE 9
positive · output
FUSE 10
positive · output
FUSE 11
positive · output
FUSE 12
positive · output
FUSE 13
positive · output
FUSE 14
positive · output
FUSE 15
positive · output
A dash means a current rating is not specified here.
Sources and sizing method
Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.
Example sizing. Wire sizes and fuse ratings apply to the connected example, not a fixed cable size for this component. Set your actual equipment, current, lengths and installation conditions in Crimp before choosing hardware.
Read how the sizing worksNext step
Plan your installation with 088-0001-001 · 15 circuits.
Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.
Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.