Parallax Power Supply · 5355 AC section (6 × 20A configuration)

Parallax 5355 AC Section · 6 × 20A Configuration connections

Review the Parallax 5355 AC Section · 6 × 20A Configuration catalog ratings, AC connection points and installation notes, then add the part to your Crimp diagram.

Connection overview

5355 AC · 6 × 20A connections.

See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.

Parallax 5355 AC Section · 6 × 20A Configuration connection overview with 1 components: 5355 AC · 6 × 20A. 0 cable connections. Crossings are not junctions.Parallax 5355 AC Section · 6 × 20A Configuration. Split-phase AC panel terminal overview. Keep L1, L2, neutral and protective earth separate. The main and branch ratings describe the selected configuration; connect loads to branch outputs and verify the installed breakers, leakage protection and bonding separately. No converter or AC installation validation is included. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.5355 AC · 6 × 20A
Parallax 5355 AC Section · 6 × 20A Configuration connection overview with 1 components: 5355 AC · 6 × 20A. 0 cable connections. Crossings are not junctions.Split-phase AC panel terminal overview. Keep L1, L2, neutral and protective earth separate. The main and branch ratings describe the selected configuration; connect loads to branch outputs and verify the installed breakers, leakage protection and bonding separately. No converter or AC installation validation is included. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.
Edit this connection overview

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Parallax 5355 AC distribution section only, with a declared 50 A two-pole main and three 20 A branches per leg. This six-branch configuration follows the supplied drawing; breakers are not factory-supplied. The 5300 manual permits up to twelve 120 V branches. L1, L2, neutral and earth stay separate; both main poles open together. The 55 A converter and DC board are omitted. GFCI protection and AC installation compliance remain unverified.

The map identifies line, neutral and protective-earth connections. This page does not calculate an AC cable size or protection rating.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

SUPPLY L1

neutral · input

50 A

SUPPLY L2

neutral · input

50 A

SUPPLY N

neutral · input

50 A

SUPPLY PE

ground · input

50 A

L1 / 1 L

neutral · output

20 A

L1 / 1 N

neutral · bidi

20 A

L1 / 1 PE

ground · bidi

20 A

L1 / 2 L

neutral · output

20 A

L1 / 2 N

neutral · bidi

20 A

L1 / 2 PE

ground · bidi

20 A

L1 / 3 L

neutral · output

20 A

L1 / 3 N

neutral · bidi

20 A

L1 / 3 PE

ground · bidi

20 A

L2 / 1 L

neutral · output

20 A

L2 / 1 N

neutral · bidi

20 A

L2 / 1 PE

ground · bidi

20 A

L2 / 2 L

neutral · output

20 A

L2 / 2 N

neutral · bidi

20 A

L2 / 2 PE

ground · bidi

20 A

L2 / 3 L

neutral · output

20 A

L2 / 3 N

neutral · bidi

20 A

L2 / 3 PE

ground · bidi

20 A

L1 BUS

neutral · bidi

50 A

L2 BUS

neutral · bidi

50 A

N BUS

neutral · bidi

50 A

PE BUS

ground · bidi

50 A
Sources and connection guidance

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

AC planning boundary. The drawing identifies conductors and connection points; supported switching states show contact continuity only. Crimp does not calculate AC load flow or verify fault protection, leakage trips, source isolation or grounding. This overview does not calculate cable sizes or validate protective devices. Follow the complete manufacturer installation instructions.

Read about the DC sizing method and its limits

Next step

Plan your installation with 5355 AC · 6 × 20A.

Open the connection overview as a new project, or add this component to a diagram you already have.