Parallax Power Supply · 5355 AC section (6 × 20A configuration)
Parallax 5355 AC Section · 6 × 20A Configuration connections
Review the Parallax 5355 AC Section · 6 × 20A Configuration catalog ratings, AC connection points and installation notes, then add the part to your Crimp diagram.
Connection overview
5355 AC · 6 × 20A connections.
See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.
Technical reference
Specifications and terminal map.
Check the model, ratings and connection points against your own unit before choosing installation hardware.
Catalog specification
Parallax 5355 AC distribution section only, with a declared 50 A two-pole main and three 20 A branches per leg. This six-branch configuration follows the supplied drawing; breakers are not factory-supplied. The 5300 manual permits up to twelve 120 V branches. L1, L2, neutral and earth stay separate; both main poles open together. The 55 A converter and DC board are omitted. GFCI protection and AC installation compliance remain unverified.
The map identifies line, neutral and protective-earth connections. This page does not calculate an AC cable size or protection rating.
Terminal map
Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.
SUPPLY L1
neutral · input
SUPPLY L2
neutral · input
SUPPLY N
neutral · input
SUPPLY PE
ground · input
L1 / 1 L
neutral · output
L1 / 1 N
neutral · bidi
L1 / 1 PE
ground · bidi
L1 / 2 L
neutral · output
L1 / 2 N
neutral · bidi
L1 / 2 PE
ground · bidi
L1 / 3 L
neutral · output
L1 / 3 N
neutral · bidi
L1 / 3 PE
ground · bidi
L2 / 1 L
neutral · output
L2 / 1 N
neutral · bidi
L2 / 1 PE
ground · bidi
L2 / 2 L
neutral · output
L2 / 2 N
neutral · bidi
L2 / 2 PE
ground · bidi
L2 / 3 L
neutral · output
L2 / 3 N
neutral · bidi
L2 / 3 PE
ground · bidi
L1 BUS
neutral · bidi
L2 BUS
neutral · bidi
N BUS
neutral · bidi
PE BUS
ground · bidi
Sources and connection guidance
Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.
AC planning boundary. The drawing identifies conductors and connection points; supported switching states show contact continuity only. Crimp does not calculate AC load flow or verify fault protection, leakage trips, source isolation or grounding. This overview does not calculate cable sizes or validate protective devices. Follow the complete manufacturer installation instructions.
Read about the DC sizing method and its limitsNext step
Plan your installation with 5355 AC · 6 × 20A.
Open the connection overview as a new project, or add this component to a diagram you already have.
Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.