Load

Vitrifrigo C51i CHR 12/24V connections

Review the Vitrifrigo C51i CHR 12/24V connections, setup and installation requirements. This overview does not calculate cable or protection sizes.

Nominal voltage
12 V
Compatible systems
12 V / 24 V

Connection overview

C51i CHR connections.

See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.

Vitrifrigo C51i CHR 12/24V connection overview with 3 components: C51i CHR, Fridge fuse + isolator, 12 V House battery. 4 cable connections. Crossings are not junctions.12 V House battery + to Fridge fuse + isolator +: 15 A specified fuse. 12 V House battery − to Fridge fuse + isolator −. Fridge fuse + isolator + to C51i CHR +. Fridge fuse + isolator − to C51i CHR −12 V House battery + to Fridge fuse + isolator +: 15 A specified fuse12 V House battery − to Fridge fuse + isolator −Fridge fuse + isolator + to C51i CHR +Fridge fuse + isolator − to C51i CHR −Vitrifrigo C51i CHR 12/24V. The exact C51i CHR sheet does not publish electrical consumption. Use the installed unit's electrical label and compressor instructions to establish the load before sizing its supply; the family manual's fuse rating is not operating current. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.C51i CHR++−−Fridge fuse + isolator. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.Fridge fuse + isolator++−−++−−12 V House battery. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.12 V House battery++−−15 A specified fuse
Vitrifrigo C51i CHR 12/24V connection overview with 3 components: C51i CHR, Fridge fuse + isolator, 12 V House battery. 4 cable connections. Crossings are not junctions.The exact C51i CHR sheet does not publish electrical consumption. Use the installed unit's electrical label and compressor instructions to establish the load before sizing its supply; the family manual's fuse rating is not operating current. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.
Edit this connection overview

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. C-series CC-CA instruction manual; C51i CHR exact-model data sheet), checked 2026-10-01. Manufacturer documentation →

Which refrigerator is represented?

This is the Vitrifrigo C51i CHR 12/24 V DC refrigerator, with a 51 L cabinet and 3.6 L freezer compartment. The exact-model manufacturer data sheet, retained from a distributor mirror, identifies C51i CHR but lists electrical absorption as N.A. Consequently the catalog leaves running watts, running amps and startup amps unset. Cabinet capacity and a branch fuse cannot fill that gap.

The downloaded C-series manual explicitly includes C51I. Its installation guidance is family-level; compare the compressor/controller and appliance label with the fitted CHR unit before applying controller-specific details. The catalog represents the DC input, not an optional AC/DC power module.

How should the DC circuit be protected?

The electrical instructions, pages 25–26, recommend a direct battery supply following the controller instructions. Annex 4, page 75, specifies 15 A at 12 V or 7.5 A at 24 V and a main switch rated at least 20 A. The catalog's 15 A terminal boundary is a protected-circuit planning allowance, not a claim that the fridge draws 15 A or that its connector is rated for that continuous current.

Page 26 gives cable sizes of 2.5/4/6/10 mm² against maximum 12 V line lengths of 2.5/4/6/10 m; the corresponding 24 V lengths double. Apply the actual controller's length convention and account for the complete route and connections. Without verified running and starting demand, a complete calculated circuit or daily-energy prediction remains incomplete.

How should the cabinet be installed?

The recess instructions, pages 23–25, distinguish static, fan-cooled and remote condensers. Match the actual condenser layout to its ventilation drawing instead of borrowing a clearance from another variant. Keep lower air entry and heated-air escape clear, secure the cabinet using its intended frame or mounting points, and ensure no cable sits under the cabinet. Wait at least one hour after positioning before switching on.

What should be checked if cooling is poor?

Check door closure, ventilation and voltage at the compressor while it tries to start. The family manual's standard 12 V cutout/restart thresholds are 10.4/11.7 V, but optional controller settings can differ. Low voltage at the refrigerator may result from its wiring even when the battery looks healthy. Isolate before cleaning or defrosting, avoid puncturing the refrigerant circuit, and leave the cleaned door ajar during storage as described on pages 27–29.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

51 L compressor fridge with 3.6 L freezer. The exact-model sheet lists electrical absorption as N.A.; operating and starting current remain unset. The C-series family manual specifies 15 A protection at 12 V or 7.5 A at 24 V. Terminal 15 A is a protected-circuit planning boundary, not a measured load or connector rating.

Nominal voltage
12 V
Compatible systems
12 V / 24 V

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · input

15 A

−

negative · input

15 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Connection overview. This diagram explains the connection arrangement; it does not calculate cable sizes or protection for the installation. Follow the manufacturer’s complete wiring and protection instructions.

Read how the sizing works

Next step

Plan your installation with C51i CHR.

Open the connection overview as a new project, or add this component to a diagram you already have.

Free for up to 10 equipment components, with no account needed. Cables, busbars and fuse hardware do not count toward the limit. Your drawing saves in this browser. File exports are included with Crimp Pro.