Load

Truma Combi 4 E wiring diagram

Review how the Truma Combi 4 E connects, how it operates and which installation requirements apply to this model.

Open this example as a new project. Use your own parts and cable lengths to make the plan yours.

Connection and installation overview

The Combi 4 E needs a protected 12 V control and fan supply even when heating from gas or 230 V. Its DC protection depends on whether it connects through the vehicle's central electrical system or directly to a battery. Follow the separate DC, AC, gas and water installation instructions.

The Combi 4 E needs a protected 12 V control and fan supply even when heating from gas or 230 V. Its DC protection depends on whether it connects through the vehicle's central electrical system or directly to a battery. Follow the separate DC, AC, gas and water installation instructions.

Show sizes in AWG

Wiring diagram

How the Combi 4 E is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

See the field notes for this part’s connections and installation requirements.
Start a diagram with this part

Installation notes

Connections and installation requirements.

Guidance for this model, with sources linked beside the relevant advice.

Verified against the manufacturer's documentation (rev. 34020-00413 · 01 · 09/2018, Combi 2 E / 4 E installation instructions), checked 2026-10-01. Manufacturer documentation →

Which Combi and which energy sources?

This entry is the Combi 4 E gas/electric space and water heater. It needs a 12 V supply for electronics and the circulation fan even when heating from 230 V. The technical data, page 22, gives 1.2–6.5 A at 12 V for Combi 4 (E), plus separate electric-heater stages of 900 W/3.9 A and 1800 W/7.8 A at 230 V. The catalog uses the upper 6.5 A DC demand. Gas heat output of 2 or 4 kW is not electrical draw; the electric heating element is a separate shore-power load.

How is the 12 V branch connected?

The connector diagram, page 20, identifies terminal 40 as +12 V and 41 as ground, both 6.3 mm spades. Its internal F10A quick-acting fuse is separate from the branch-protection instruction on page 21: connect to a 10 A fused on-board circuit, using 2 × 2.5 mm² cable, or 2 × 4 mm² for 6–10 m total cable length. The stated maximum total length is 10 m. No other consumers should share this supply line.

When connected directly to the battery, page 21 requires protection of both positive and negative leads. Follow this installation-specific arrangement rather than treating the drawing as a generic positive-fuse-only branch. The catalog's 10 A DC-terminal boundary represents the specified protected supply; it is not a measured load.

What is required for mains heating?

The 230 V instructions, page 21, require a circuit rated at least 10 A, preferably 16 A, a suitable residual-current device and an all-pole maintenance disconnect with at least 3.5 mm contact separation. AC L, N and PE are shown separately in the catalog. Keep mains and low-voltage wiring apart, and have the gas and mains installations completed and tested by qualified installers.

What should be checked at commissioning?

Check gas tightness, secure exhaust and combustion-air connections, unobstructed warm-air outlets and room-sensor placement. Fill and check the water system, then test draining through the frost-protection valve. The tank's 10 L capacity is not protection against freezing: drain according to the operating instructions whenever frost exposure is possible. If heating stops, check both supplies and the actual controller fault code; increasing a fuse rating is not a remedy for a recurring fault.

Build it out

Connect it to the rest of your system.

Add Combi 4 E to your diagram, then connect your batteries, chargers and loads. Crimp calculates cable sizes and checks the connections as you draw.

Every cable you draw there is sized against ABYC E-11, from the same tables as the reference on this page.

Technical reference

Specifications, terminals and supporting parts.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Nominal voltage
12 V
Compatible systems
12 V
Continuous draw
6.5 A

Supporting parts

  1. A lug or terminal to match each post on the part
  2. Strain relief and boots so nothing chafes or shorts
  3. Cable and fuses sized once the whole system is drawn

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

pos

positive · input

10 A

−

neg

negative · input

10 A

230V L

ac-l

neutral · input

7.8 A

230V N

ac-n

neutral · input

7.8 A

PE

ac-pe

ground · input

7.8 A

Method & provenance

Where the specifications and sizing come from.

Manufacturer specifications describe the equipment. Crimp calculates cable results from the circuit and assumptions you enter.

From the maker

What the catalog says

Manufacturer, model, ratings and which terminal does what come from the catalog. A newer revision, or the nameplate on the unit in your hand, can say something different — when it does, the nameplate wins.

ABYC E-11

What Crimp worked out

Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. The run length and the current above are what drive the result. Crimp doesn't know how warm your space gets; draw the cable inside an engine-bay zone on the canvas and it sizes for the heat.

Read how the sizing works

Next step

Plan your installation with Combi 4 E.

Open this example as a new project. Add your equipment and cable lengths, then review the sizing and checks for your setup.