Load
Lenco 100 Series 9×9 Kit 15000-101 connections
Review the Lenco 100 Series 9×9 Kit 15000-101 connections, setup and installation requirements. This overview does not calculate cable or protection sizes.
- Nominal voltage
- 12 V
- Compatible systems
- 12 V
Connection overview
100 Series 9×9 connections.
See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.
Installation notes
Before you install.
Open a question for model-specific guidance and sources.
Reviewed against manufacturer family documentation (rev. Lenco Owner’s Manual, copyright 2023), checked 2026-10-01. Exact variant details still require confirmation. Manufacturer documentation →
A tab-and-actuator kit needing controls
15000-101 is the 12 V 100 Series standard-mount kit with two 9 × 9 inch trim-tab blades, two actuators, extension harnesses and mounting hardware. It does not include a switch kit. A trim-tab installation needs controls suited to the actuators and desired functions before its wiring can be finalized.
Lowering a tab increases lift at that side of the stern. The control labels describe the desired bow movement, so the left side of the helm control operates the opposite tab. This is why actuator connector identification matters even when both motors move successfully.
Reserve the control supply, not bare motor wiring
The catalog's positive and negative terminals represent the supply to a future compatible control assembly. They are not instructions to connect the actuator leads permanently to a battery. The controller reverses actuator motion and, on applicable controls, manages automatic retraction.
For the standard integrated 15169-001 single-actuator-per-tab arrangement, the 2023 manual's p. 12 diagram specifies 20 A fuse or breaker protection at 12 V. It also shows the separate orange retract-sense lead connected to an on/off source, with the main red/black supply arranged as drawn. Do not assume that simply interrupting the main feed preserves automatic retraction. Other controls have their own diagrams.
The 20 A figure is a protection choice for that example, not measured running current. Both operating draw and surge remain unset until the actual controls and load are established. The terminal limit is a planning bound, and verification remains family-only for the unselected control circuit.
Fit the mechanics before trimming the wiring
Use the standard-mount dimensions and the table for a 9-inch blade; edge-mount dimensions belong to another kit. Check inside the transom before drilling. Support the upper bracket in its natural alignment with the actuator and blade so the mechanism does not bind. Seal fasteners and cable penetrations using the manual's gland and bedding arrangement.
Route the provided actuator extensions to the selected control location, preserving Deutsch connector pin positions and the port/starboard identification. Allow service access. Do not substitute a guessed battery-feed cable size for the manufacturer's actuator harness requirements.
Commission direction, retraction and handling
With the vessel secure, confirm each bow-labelled command moves the intended tab in the correct direction. Check complete travel without binding and verify the chosen controller's retract behavior. At sea, make short adjustments and observe the boat's response; avoid a large one-sided command at speed and retract the tabs in a following sea as instructed.
For a failed side, inspect its connector and harness before replacing the actuator. For faults on both sides, check the control supply and protection. Periodically inspect brackets, seals, anodes and the stainless surfaces; corrosion resistance does not remove the need for maintenance.
Manuals and evidence
2023 Lenco Owner's Manual, distributor-hosted manufacturer PDF, pp. 3–9 (operation/mechanics), p. 12 (15169-001 circuit) and pp. 24–25 (faults). Official 100 Series range identifies 15000-101 and its size. The complete PDF and verified wiring-diagram page are recorded in the ledger.
Technical reference
Specifications and terminal map.
Check the model, ratings and connection points against your own unit before choosing installation hardware.
Catalog specification
12 V standard-mount kit with two 9×9-inch blades and actuators; switch kit is sold separately. Symbol reserves the future controller supply, not direct motor connections. The standard single-actuator-per-tab diagrams specify 20 A protection at 12 V, not operating current. Consumption remains unset until controls and duty are known; terminal limit is a planning bound.
- Nominal voltage
- 12 V
- Compatible systems
- 12 V
Terminal map
Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.
Control supply +
positive · input
−
negative · input
Sources and sizing method
Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.
Connection overview. This diagram explains the connection arrangement; it does not calculate cable sizes or protection for the installation. Follow the manufacturer’s complete wiring and protection instructions.
Read how the sizing worksNext step
Plan your installation with 100 Series 9×9.
Open the connection overview as a new project, or add this component to a diagram you already have.
Free for up to 10 equipment components, with no account needed. Cables, busbars and fuse hardware do not count toward the limit. Your drawing saves in this browser. File exports are included with Crimp Pro.