Rule 33ALA High Water Bilge Alarm wiring diagram

Review how the Rule 33ALA High Water Bilge Alarm connects, how it operates and which installation requirements apply to this model.

Open this example as a new project. Use your own parts and cable lengths to make the plan yours.

Connection and installation overview

Separate series float is required and the manual does not publish alarm draw; the 20 A table value is a switch rating.

Separate series float is required and the manual does not publish alarm draw; the 20 A table value is a switch rating.

Show sizes in mm²

Wiring diagram

How the 33ALA is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Rule 33ALA High Water Bilge Alarm wiring example with 1 components: 33ALA. 0 cable connections. Crossings are not junctions.Rule 33ALA High Water Bilge Alarm. Separate series float is required and the manual does not publish alarm draw; the 20 A table value is a switch rating. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.33ALA
Rule 33ALA High Water Bilge Alarm wiring example with 1 components: 33ALA. 0 cable connections. Crossings are not junctions.Separate series float is required and the manual does not publish alarm draw; the 20 A table value is a switch rating. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.Scroll sideways to inspect all components and connections.

This supply example retains the manufacturer's 1 A fuse. Follow the complete installation notes for connector polarity, mounting, controls and commissioning; verify the actual cable route and equipment revision. Manufacturer installation manual

Edit this connection overview

Installation notes

Connections and installation requirements.

Guidance for this model, with sources linked beside the relevant advice.

Verified against the manufacturer's documentation (rev. 950-0524 Rev F, July 2021), checked 2026-10-01. Manufacturer documentation →

Use a dedicated high-water float

33ALA is the 12 V alarm kit. It is intended to warn when bilge water rises beyond the normal pump-control level. Place its float about 2 inches (5 cm) above the existing bilge-pump float switch, with clearance for full travel. Sharing the ordinary pump float would cause an alarm during normal pump cycles and would lose the intended independent high-water threshold.

Follow the series alarm wiring

The manual’s wiring diagram shows battery positive, the high-water float, a 1 A fuse, then the red alarm lead; the black alarm lead returns to battery negative. Provide source-side protection for the wiring as required by the installation as well as retaining the specified alarm fuse. The catalog’s supply pair represents the alarm circuit as an assembly; it does not show the float closed inside the enclosure. No current demand is derived from the 20 A float-switch rating in the model table.

Mount the panel and float for their different jobs

Put the audible/visual panel where the alarm can be heard and seen. The panel cutout is 2.125 inches (54 mm). Keep sealed joints above expected bilge water, support the cable and follow the float mounting illustration, including its 30-degree longitudinal and 5-degree transverse limits. The equipment tolerates the illustrated spray exposure; that is not permission to direct a cleaning jet into it or expose it to fuel and corrosive liquids.

Test the warning rather than only the pump

Lift the high-water float’s test lever and verify both audible and visual indications at the normal helm position. Lower it and confirm the alarm clears. Repeat during routine bilge checks and inspect the separate float for obstructions. A running bilge pump does not prove this circuit is healthy. The walkthrough is an overview because the external float topology and unpublished alarm consumption cannot be represented by an ordinary fixed-current load example.

Manual and scope

Rule installation manual, 950-0524 Rev F, July 2021; pp. 3–5 mounting, p. 8 functional test, p. 10 series circuit with 1 A fuse, p. 14 model table. The original PDF is retained in the marine source ledger. The drawing represents the identified electrical interfaces; it does not simulate the equipment’s mechanical performance, radio signals or fluid system. Unpublished connector ampacity and startup current remain unspecified.

Build it out

Connect it to the rest of your system.

Add 33ALA to your diagram, then connect your batteries, chargers and loads. Crimp calculates cable sizes and checks the connections as you draw.

Every cable you draw there is sized against ABYC E-11, from the same tables as the reference on this page.

Technical reference

Specifications, terminals and supporting parts.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Nominal voltage
12 V
Compatible systems
12 V

Supporting parts

  1. A lug or terminal to match each post on the part
  2. Strain relief and boots so nothing chafes or shorts
  3. Cable and fuses sized once the whole system is drawn

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

Alarm circuit +

pos

positive · input

—

Alarm circuit −

neg

negative · input

—

A dash means a current rating is not specified here.

Method & provenance

Where the specifications and sizing come from.

Manufacturer specifications describe the equipment. Crimp calculates cable results from the circuit and assumptions you enter.

From the maker

What the catalog says

Manufacturer, model, ratings and which terminal does what come from the catalog. A newer revision, or the nameplate on the unit in your hand, can say something different — when it does, the nameplate wins.

ABYC E-11

What Crimp worked out

Sized against ABYC E-11 — the US reference, and what Transport Canada accepts as an alternative to TP 1332 for pleasure craft under 24 m. The run length and the current above are what drive the result. Crimp doesn't know how warm your space gets; draw the cable inside an engine-bay zone on the canvas and it sizes for the heat.

Read how the sizing works

Next step

Plan your installation with 33ALA.

Open this example as a new project. Add your equipment and cable lengths, then review the sizing and checks for your setup.