Charger

Victron Phoenix Smart IP43 12/30 (1+1) wiring diagram

Pictured universal-input Smart IP43 12/30 (1+1): 30A total with a starter output limited to 4A. Input 85–250 VAC, startup from 90V and full power from 100V. Verify regional version; use a dry, ventilated installation.

Compatible systems
12 V
Rated output
30 A
Units

Wiring diagram

How the Phoenix 30A (1+1) is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Victron Phoenix Smart IP43 12/30 (1+1) wiring example with 3 components: Phoenix 30A (1+1), Battery disconnect, House bank. 3 cable connections. Crossings are not junctions.Phoenix 30A (1+1) BATT + to Battery disconnect A: 10 mm² · 40 A fuse, 3 m one way. Phoenix 30A (1+1) BATT − to House bank −: 10 mm², 3 m one way. Battery disconnect B to House bank +: 10 mm² · 40 A fuse, 30 cm one wayPhoenix 30A (1+1) BATT + to Battery disconnect A: 10 mm² · 40 A fuse, 3 m one wayPhoenix 30A (1+1) BATT − to House bank −: 10 mm², 3 m one wayBattery disconnect B to House bank +: 10 mm² · 40 A fuse, 30 cm one wayVictron Phoenix Smart IP43 12/30 (1+1)Phoenix 30A (1+1)BATT +BATT +BATT −BATT −Main Battery SwitchBattery disconnectAB12 V 120 Ah AGM placeholder bank. Example bank only: select the correct charger profile and confirm the actual battery's capacity, charging-current acceptance, voltage and temperature limits. Placeholder current limits are not manufacturer battery specifications.House bank++−−10 mm² · 40 A fuse10 mm²10 mm² · 40 A fuse
Victron Phoenix Smart IP43 12/30 (1+1) wiring example with 3 components: Phoenix 30A (1+1), Battery disconnect, House bank. 3 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
10 mm² · 8 AWG
Example fuse
40 A
Design current
30 A
Voltage drop
2.7%

Sized against ABYC E-11. The design current is the unit's rated output. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 10 mm² (8 AWG) marine cable
  2. Terminations for 10 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 40 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Rev 10 — 09/2026), checked 2026-10-01. Manufacturer documentation →

Which Smart IP43 is covered?

These notes cover the Smart IP43 12/30 (1+1), 120–240 V version visible in the catalog photograph. It supplies up to 30 A total to nominal 12 V batteries. The current manual specifies 85–250 VAC, startup from 90 VAC and full power from 100 VAC. Older 230 V-only Phoenix units need their matching instructions; the family name alone does not make their input range or auxiliary rating identical.

How do the outputs map?

BATT + / BATT − are the main charging output. START + / START − map to the separate low-current starter connector. The current universal-input manual specifies 4 A maximum at the starter output, with the combined main-plus-starter current limited to the charger rating. Do not infer 3 A from older Phoenix-family descriptions or use this small output as a second full-power charger.

AC L / N / earth describe the IEC mains inlet and protective-earth connection. The symbol omits remote H/L, programmable relay, and VE.Direct. Use the correct mains cord with its retainer and an earthed outlet. The remote connector can receive a compatible BMS charge-permission control; it does not carry charging current.

What cable and protection are specified?

The printed page 19 table recommends 10 mm² through 3 m one way or 16 mm² for 3–4.5 m; 4.5–6 m is not recommended. These values assume at least 90°C insulation, open unbundled routing at 30°C, equal positive/negative lengths, and a 3% voltage-drop limit. They do not approve the same cable in every conduit or engine space.

Main DC terminals accept up to 16 mm² and tighten to 2.4 N·m. Fit suitable protection close to each battery positive. This manual's wiring diagrams require fuses/breakers but do not give a universal model-specific fuse amperage; select the rating with the installed conductor and battery fault current rather than borrowing another charger family's table.

What must be set before charging?

Select battery chemistry, charge voltage/current, and any required BMS control before use. Low mode limits this model to 15 A. Normal mode is 14.4 V absorption, 13.8 V float and 13.2 V storage; lithium uses its own preset without lead-acid temperature compensation. Configure all banks for one compatible charging profile. Remote control and the programmable relay have distinct functions; a relay signal is not a substitute for wiring the charge-disable input correctly.

How is the installation checked?

Mount vertically, terminals down, with 100 mm ventilation space above and below, on a nonflammable surface. Use a protected, dry location away from battery gases. Verify each bank's polarity and charging voltage, then test the configured current limit and any BMS stop command. The specification table rates full current through 40°C; heat and connected loads reduce charging headroom.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with Phoenix Smart IP43 12/30 (1+1) connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Pictured universal-input Smart IP43 12/30 (1+1): 30A total with a starter output limited to 4A. Input 85–250 VAC, startup from 90V and full power from 100V. Verify regional version; use a dry, ventilated installation.

Compatible systems
12 V
Rated output
30 A
Planning charge current
28 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

AC L

neutral · input

16 A

AC N

neutral · input

16 A

AC ⏚

ground · bidi

16 A

BATT +

positive · output

30 A

BATT −

negative · output

30 A

START +

positive · output

4 A

START −

negative · output

4 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Phoenix 30A (1+1).

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.