How-to wiring diagram
12V fridge wiring diagram: how to wire a compressor fridge
Wire a compressor fridge on its own fused circuit, from the fuse block or straight from the battery, with no plug, socket or extra switch in the cable. The fuse size comes from the fridge manual: Dometic specifies 15 A at 12 V for the CRX 50 in the drawing, although it only draws about 5 A while the compressor runs. The wire matters as much as the fuse. A compressor fridge measures the voltage at its own terminals and switches off when it sags, so a thin or long cable makes it cut out while the battery is still healthy. For a 4 m run Crimp sizes 6 mm²; check your own length against the cable chart in your fridge's manual.
The wiring diagram
The fridge has a fuse-block slot of its own and a dedicated return. Change the cable length in the live drawing to see the wire size change.
3 components · 4 conductors

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.
View full screenRed = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.
Fridge DC connections
The DC supply wires of the Dometic CoolMatic CRX 50, from its installation manual.
| Wire | What it is | Connect it to |
|---|---|---|
| Red | DC positive | A fused positive: 15 A at 12 V, 7.5 A at 24 V |
| Black | DC negative | The negative bus or battery negative |
AC/DC versions of the CRX have a separate mains connection; this table covers the DC supply only.
Step by step
01
Check the fridge's fuse and cable table
Look up the fuse and the cable chart in the fridge manual. For the CRX 50 Dometic gives 15 A at 12 V and 7.5 A at 24 V, and a chart of cable cross-section against length.
02
Plan the shortest route
Keep the cable as short as you can and in one piece. Dometic says to avoid extra switches, plugs and power strips, because each one adds voltage drop.
03
Fit a fuse at the supply end
Give the fridge its own slot in the fuse block, or an inline fuse right at the battery if it runs straight there.
04
Run a matching return
Run the negative back to the fuse block's negative bus or the negative bus bar, the same size as the positive.
05
Leave room to breathe
A compressor fridge needs air in below and out above. The CRX installation drawings show about 50 mm clear behind the cabinet.
06
Check voltage at the fridge
With the compressor starting, measure at the fridge's own terminals. If it is far below the battery voltage, the cable or a connection is too poor.
Cable and fuse sizes
Sized by Crimp's ABYC E-11 based engine for the lengths shown. Lengths are one way; AWG is the approximate counterpart of the metric size.
| Connection | Length | Wire | Design current | Fuse | Drop |
|---|---|---|---|---|---|
| C1 · House battery + → Fuse block IN + | 50 cm1.6 ft | 6 mm²AWG 10 | 5 A | — | 0.06% |
| C2 · Fuse block 1 + → Compressor fridge + | 4 m13.1 ft | 6 mm²AWG 10set size | 5 A | 15 A | 0.46% |
| C3 · Compressor fridge − → Fuse block 1 − | 4 m13.1 ft | 6 mm²AWG 10 | 5 A | — | 0.46% |
| C4 · Fuse block IN − → House battery − | 50 cm1.6 ft | 6 mm²AWG 10 | 5 A | — | 0.06% |
A dash means the cable has no fuse of its own: a negative, a cable past a switch, or a run protected by the fuse upstream of it. Fuses on a battery post or in an inline holder are drawn on the diagram.
Common mistakes
Crimp's checks on this drawing: 0 critical, 2 to review. They stay visible when you open it.
- Running it through a cigarette socket and plug. The contacts add resistance and the plug can work loose, so the fridge cuts out on a healthy battery.
- Sizing the wire for 5 A alone. The wire must carry its 15 A fuse, and a long run also needs size for voltage drop.
- Fitting a fuse bigger than the manual says. The fuse protects the wire; a bigger one can let a fault overheat it.
- Boxing the fridge in. Without airflow the compressor runs longer, uses more energy and can trip on overheating.
- Treating the fridge's cut-out as the battery's limit. 10.4 V is when this fridge gives up, not a safe discharge level for your battery.
- warning: No charging source
- info: Check fuse suitability: House battery
A planning example, not an installation certificate. Sizing follows Crimp's published method; check the manufacturer documents below for your exact parts.
Questions
What size fuse for a 12V fridge?
Use the rating in the fridge's manual. Dometic specifies 15 A at 12 V and 7.5 A at 24 V for the CRX 50. That is three times the 5 A running current; size the cable to carry the fuse, not just the fridge.
What size wire for a 12V fridge?
It depends on the cable length and the fuse. For the 4 m run in the drawing Crimp sizes 6 mm². Shorter runs can be thinner; check your length against the chart in your fridge manual, or open the drawing and change the length.
Can I wire a 12V fridge directly to the battery?
Yes, with a fuse close to the battery. The CRX manual's DC steps connect the red cable to the battery positive and the black to the negative. A fuse block is neater when you have several circuits.
Why does my 12V fridge keep cutting out?
Usually voltage drop. The fridge measures the voltage at its own terminals, and the CRX 50 switches off below 10.4 V and restarts at 11.7 V. A thin cable, a cigarette plug or a loose crimp can pull the voltage that low while the compressor starts, even when the battery reads fine.
How many amps does a 12V compressor fridge use?
While the compressor runs, the CRX 50 draws 5.0 A at 12 V. It cycles on and off, so the daily total depends on the temperature and how often it is opened. If it ran 8 hours in a day, that would be 40 Ah.
Should a 12V fridge have a switch?
Not an extra one in the supply cable: Dometic advises against additional switches because each adds voltage drop. Use the fridge's own control, and the main battery switch to isolate the whole system.