Load
Minn Kota Terrova 80 24V 1358380 connections
Review the Minn Kota Terrova 80 24V 1358380 connections, setup and installation requirements. This overview does not calculate cable or protection sizes.
- Nominal voltage
- 24 V
- Compatible systems
- 24 V
Connection overview
Terrova 80 connections.
See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.
Installation notes
Before you install.
Open a question for model-specific guidance and sources.
Verified against the manufacturer's documentation (rev. Terrova 2327134 Rev E, ECN 44629, 01/2024), checked 2026-10-01. Manufacturer documentation →
The exact 24 V Terrova
1358380 is the brushed freshwater Terrova with 80 lb thrust, a 60-inch shaft and wireless remote. It is not the QUEST brushless variant, and this SKU does not include a foot pedal or built-in sonar. The heading sensor supports the relevant GPS functions, but is an additional installation item with its own wiring and placement instructions.
Build the correct motor supply
Use a 24 V supply arrangement matching Minn Kota's battery instructions. With two 12 V batteries in series, connect the motor across the full bank, not across one battery. Confirm polarity and total voltage before connecting. Do not power unrelated electronics from one half of that series bank or add charger/ground connections that defeat the manufacturer's isolation and bonding guidance.
For an 80 lb motor, the manual specifies a 60 A circuit breaker with at least a 24 V DC rating. Its current table lists 56 A as maximum intermittent draw and explicitly says it is not a continuous current rating. The catalog leaves continuous draw and startup surge unset; neither 56 A nor the 60 A breaker is an honest all-day consumption estimate. Terminal values are protection-based planning bounds.
Use the manufacturer's extension table
The 80 lb row specifies extension conductors of 8 AWG for 5 ft, 6 AWG for 10 or 15 ft, 4 AWG for 20 ft, and 2 AWG for 25 ft. These are the manual's extension lengths and assumptions, not a generic substitute for the complete circuit design. The table assumes 105 °C conductors, limited bundling outside engine spaces and no more than 3% drop at maximum power. Longer or materially different installations need a revised design.
Keep battery connections clean, covered and mechanically secure. Match the battery and charger to the series arrangement. The reviewed manual cautions that lithium batteries hold higher voltage and that prolonged operation above 85% speed can damage this motor; verify the applicable battery guidance for the actual hardware before configuring it.
Mount, deploy and test under control
Check bow clearance, shaft travel and secure stowage before drilling. Follow the mounting instructions for the base and any stabilizer. Keep people and objects clear of the propeller whenever power is connected, and disconnect the motor before propeller work.
Commission steering, remote control and propeller operation in a clear area, then calibrate the heading/GPS system using its instructions. Confirm you can cancel automatic control promptly. Position-hold performance depends on satellite reception, wind, current and available thrust; maintain an operator and an appropriate conventional anchoring plan. For weak thrust or resets, inspect battery condition, connection drop and the propeller before changing protection.
Manuals and evidence
Terrova product manual, English pp. 36–39, covers circuit protection, extension sizes, battery cautions and 24 V wiring. The PDF is actually Rev E despite the older filename. Exact 1358380 product page confirms the selected hardware and links its heading-sensor and remote manuals. The original 76 MB PDF is retained in the evidence archive.
Technical reference
Specifications and terminal map.
Check the model, ratings and connection points against your own unit before choosing installation hardware.
Catalog specification
24 V, 80 lb Terrova with 60-inch shaft and advanced GPS remote. Manufacturer specifies a 60 A breaker rated for at least 24 V; 56 A is maximum intermittent current, explicitly not continuous. No average draw or startup surge is assigned. Size wiring from the manufacturer extension table and actual route. Terminal values are protection-based planning bounds.
- Nominal voltage
- 24 V
- Compatible systems
- 24 V
Terminal map
Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.
+
positive · input
−
negative · input
Sources and sizing method
Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.
Connection overview. This diagram explains the connection arrangement; it does not calculate cable sizes or protection for the installation. Follow the manufacturer’s complete wiring and protection instructions.
Read how the sizing worksNext step
Plan your installation with Terrova 80.
Open the connection overview as a new project, or add this component to a diagram you already have.
Free for up to 10 equipment components, with no account needed. Cables, busbars and fuse hardware do not count toward the limit. Your drawing saves in this browser. File exports are included with Crimp Pro.