Q24D / E70498

Raymarine Quantum 2 Q24D E70498 wiring diagram

12/24 V Doppler radar; 10.8–31.2 V input, 17 W maximum transmit, 7 W standby, 2 W Wi-Fi sleep. Use a 5 A fuse or 3 A thermal breaker. Catalog current is 17 W / 12 V, a nominal-voltage calculation. RayNet or Wi-Fi carries data; either installation still needs DC power. Terminal values are protection-based planning bounds.

Nominal voltage
12 V
Compatible systems
12 V / 24 V
Rated power
17 W

Wiring diagram

How the Quantum 2 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Raymarine Quantum 2 Q24D E70498 wiring example with 3 components: House bank, Fused DC distribution, Quantum 2. 4 cable connections. Crossings are not junctions.Fused DC distribution 1 to Quantum 2 +: 1.5 mm² · 5 A fuse, 3 m one way. Fused DC distribution 1 to Quantum 2 −: 1.5 mm², 3 m one way. House bank + to Fused DC distribution IN +: 1.5 mm² · 2 A fuse, 30 cm one way. House bank − to Fused DC distribution IN −: 1.5 mm², 30 cm one wayFused DC distribution 1 to Quantum 2 +: 1.5 mm² · 5 A fuse, 3 m one wayFused DC distribution 1 to Quantum 2 −: 1.5 mm², 3 m one wayHouse bank + to Fused DC distribution IN +: 1.5 mm² · 2 A fuse, 30 cm one wayHouse bank − to Fused DC distribution IN −: 1.5 mm², 30 cm one way12 V 200 Ah house bankHouse bank++−−Blue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Raymarine Quantum 2 Q24D E70498. This 12 V example uses the manual's 5 A fuse option and 17 W maximum transmit power as its load. The alternative is a 3 A thermal breaker, not a 3 A fuse. Follow the power extension, RF-clearance, mounting and data-connection instructions.Quantum 2++−−1.5 mm² · 5 A fuse1.5 mm²1.5 mm² · 2 A fuse1.5 mm²
Raymarine Quantum 2 Q24D E70498 wiring example with 3 components: House bank, Fused DC distribution, Quantum 2. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Cable labels are example values; use the equipment instructions and actual installation lengths.

This 12 V example uses the manual's 5 A fuse option and 17 W maximum transmit power as its load. The alternative is a 3 A thermal breaker, not a 3 A fuse. Follow the power extension, RF-clearance, mounting and data-connection instructions. Manufacturer installation manual

Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
1.5 mm² · 16 AWG
Example fuse
5 A
Design current
1.4 A
Voltage drop
0.8%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

This 12 V example uses the manual's 5 A fuse option and 17 W maximum transmit power as its load. The alternative is a 3 A thermal breaker, not a 3 A fuse. Follow the power extension, RF-clearance, mounting and data-connection instructions. Manufacturer installation manual

Show sizes in AWG

Supporting parts

  1. 6.1 m total of 1.5 mm² (16 AWG) marine cable
  2. Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 5 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 87342 Rev 6, 07/2025), checked 2026-10-01. Manufacturer documentation →

A powered radar with a separate data path

Quantum 2 Q24D, E70498, is a Doppler radar radome for compatible Raymarine displays. Its radar data can travel over RayNet or Wi-Fi. Wi-Fi removes the data cable only; the scanner still needs its own DC power cable. Heading, speed and display compatibility also affect the available tracking functions.

Supply and protection

The scanner accepts nominal 12/24 V, within 10.8–31.2 V at its connection. The manual specifies a 5 A inline fuse or 3 A thermal breaker. Follow the power-cable extension table for the chosen nominal voltage and route, rather than assuming the same cable size is suitable for both 12 V and 24 V. Connect red positive and black negative; the radar's supplied power cable has no separate drain conductor.

Published power is 17 W maximum transmitting, 7 W standby and 2 W in Wi-Fi sleep. The catalog's approximately 1.42 A is the explicit calculation 17 W / 12 V, not a current measured at every supply voltage. No startup surge is published here. Terminal limits are planning bounds from the specified protection, not connector test ratings.

Position the beam and cables

Choose a supported mounting surface and a position with a clear radar view, observing the manual's RF exclusion and compass-clearance requirements. Account for people using decks or platforms near the scanner beam. Follow the permitted fastener engagement and mounting orientation; an overlong fixing can damage the scanner. Support the cable and seal deck penetrations without compromising its connectors.

If using Wi-Fi, record the scanner credentials before installation and check link quality at the intended mounting position. Mast structure and other obstructions can impair the link. If using RayNet, follow the supported network arrangement and protect unused connectors with their caps.

Commission transmission and alignment

Confirm the radar is discovered by a compatible display and can enter standby and transmit. Check supply voltage at the scanner during operation, not merely at the switch panel. Complete the bearing-alignment procedure using a suitable fixed target, and verify the source and quality of heading/speed data before depending on Doppler or target tracking.

A powered scanner that is not discovered calls for checking pairing credentials, network cabling and software compatibility. Intermittent resets call for checking voltage drop and connector corrosion. Poor target alignment calls for calibration and sensor checks. Isolate scanner power before servicing or entering the defined exposure area; a display menu alone is not physical electrical isolation.

Manual and evidence

Quantum installation instructions, Rev 6: installation and location chapters, power pp. 54–57 and electrical specifications p. 79. The full PDF is downloaded and hashed in the marine ledger. The power-only catalog symbol does not model radio coverage or network traffic.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

12/24 V Doppler radar; 10.8–31.2 V input, 17 W maximum transmit, 7 W standby, 2 W Wi-Fi sleep. Use a 5 A fuse or 3 A thermal breaker. Catalog current is 17 W / 12 V, a nominal-voltage calculation. RayNet or Wi-Fi carries data; either installation still needs DC power. Terminal values are protection-based planning bounds.

Nominal voltage
12 V
Compatible systems
12 V / 24 V
Rated power
17 W
Continuous draw
1.4 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · input

5 A

−

negative · input

5 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Quantum 2.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Free for up to 10 equipment components, with no account needed. Cables, busbars and fuse hardware do not count toward the limit. Your drawing saves in this browser. File exports are included with Crimp Pro.