Campervan wiring diagram
100Ah lithium van wiring diagram with 200W solar, no alternator charging
This is the simplest van system that runs a compressor fridge: one 100 Ah LiFePO4 battery, two 100 W panels on the roof, a solar charge controller and a fuse block. Nothing charges it from the engine, so there is no wiring to the vehicle battery at all. It suits summer weekends and holidays where the van stays parked in the sun. In summer the panels put back about what the fridge, lights, fan and phones use. In winter they cover less than half of it, so plan on a hook-up, or on adding a DC-DC charger later.
The wiring diagram
15 components · 24 conductors · 12 V

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.
View full screenRed = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.
What it powers
Each load's draw comes from its catalog entry. The hours are this guide's assumptions; change them to yours.
| Load | Draw | Hours a day | Energy a day | Why |
|---|---|---|---|---|
| Compressor fridge | 60 W | 6 h | 360 Wh | A compressor fridge cycles; about a quarter of the day, more in hot weather. |
| LED lights | 24 W | 4 h | 96 Wh | Evenings. |
| Roof fan | 60 W | 4 hsummer only | 240 Wh | Warm evenings at full speed; lower speeds draw less. |
| Water pump | 72 W | 0.25 h | 18 Wh | About 15 minutes of washing and cooking. |
| USB-C charging | 60 W | 2 h | 120 Wh | A laptop and phones at full 60 W. |
| Total a day | 834 Wh summer 594 Wh winter |
Energy budget
What goes in against what comes out, per day. Solar assumes 5 peak sun hours in summer and 1.5 in winter at 75 % panel-to-battery efficiency. Nothing charges the battery while driving.
A summer day
- Solar in
- +750 Wh
- Used
- −834 Wh
- Net
- −84 Wh
The battery loses about 8 % of its usable charge a day; a full battery lasts about 12 days like this.
A winter day
- Solar in
- +225 Wh
- Used
- −594 Wh
- Net
- −369 Wh
The battery loses about 36 % of its usable charge a day; a full battery lasts about 2 days like this.
With no charging at all, the 1,024 Wh above a 20 % reserve lasts about 1.2000000000000002 days at the larger daily use. In Crimp, switch loads on and off in the drawing to see the live current and runtime.
Parts list
15 parts. Each links to its Crimp page with the manufacturer's ratings and installation notes.
- Roof solar panel 100 W 1RNG-100D-SS18.6 V · 5.38 A rated / planning output · 100 W · 22.3 V STC Voc
- Roof solar panel 100 W 2RNG-100D-SS18.6 V · 5.38 A rated / planning output · 100 W · 22.3 V STC Voc
- Solar isolatorPlanning placeholder
- Solar charge controllerSmartSolar 100/2020 A rated / planning output
- House battery 100 Ah LiFePO4RBT12100LFP-M12.8 V · 100 Ah
- Battery monitorSmartShunt 500A/50mV (IP21)
- Main battery switchPlanning placeholder
- Positive bus barPlanning placeholder
- Negative bus barPlanning placeholder
- Fuse block5025
- Compressor fridgeCRX-505 A load allowance
- LED lightsPlanning placeholder2 A load allowance · 24 W
- Roof fanMaxxfan Deluxe 7500K5 A load allowance
- Water pumpUniversal6 A load allowance
- USB-C chargingPlanning placeholder5.5 A load allowance · 60 W
Cable and fuse sizes
Sized by Crimp's ABYC E-11 based engine for these lengths. Lengths are one way; AWG is the approximate counterpart of the metric size.
| Connection | Length | Wire | Design current | Fuse | Drop |
|---|---|---|---|---|---|
| C1 · Roof solar panel 100 W 1 + → Solar isolator IN + | 4 m13.1 ft | 2.5 mm²AWG 13 | 5.4 A | 7.5 A | 0.81% |
| C2 · Roof solar panel 100 W 2 + → Solar isolator IN + | 4 m13.1 ft | 2.5 mm²AWG 13 | 5.4 A | 7.5 A | 0.81% |
| C3 · Roof solar panel 100 W 1 − → Solar isolator IN − | 4 m13.1 ft | 1.5 mm²AWG 16 | 5.4 A | — | 1.35% |
| C4 · Roof solar panel 100 W 2 − → Solar isolator IN − | 4 m13.1 ft | 1.5 mm²AWG 16 | 5.4 A | — | 1.35% |
| C5 · Solar isolator OUT + → Solar charge controller PV + | 50 cm1.6 ft | 1.5 mm²AWG 16 | 10.8 A | 15 A | 0.34% |
| C6 · Solar isolator OUT − → Solar charge controller PV − | 50 cm1.6 ft | 1.5 mm²AWG 16 | 10.8 A | — | 0.34% |
| C7 · Solar charge controller BATT + → Positive bus bar + | 1 m3.3 ft | 2.5 mm²AWG 13 | 20 A | 25 A | 1.09% |
| C8 · Solar charge controller BATT − → Negative bus bar 1 − | 1 m3.3 ft | 2.5 mm²AWG 13 | 20 A | — | 1.09% |
| C9 · House battery 100 Ah LiFePO4 + → Main battery switch A | 30 cm1.0 ft | 16 mm²AWG 6manufacturer size | 23.5 A | — | 0.06% |
| C10 · Main battery switch B → Positive bus bar 1 + | 30 cm1.0 ft | 16 mm²AWG 6manufacturer size | 23.5 A | — | 0.06% |
| C11 · House battery 100 Ah LiFePO4 − → Battery monitor BATT − | 30 cm1.0 ft | 16 mm²AWG 6manufacturer size | 23.5 A | — | 0.06% |
| C12 · Battery monitor LOAD − → Negative bus bar 3 − | 30 cm1.0 ft | 16 mm²AWG 6manufacturer size | 23.5 A | — | 0.06% |
| C13 · Positive bus bar 2 + → Fuse block IN + | 50 cm1.6 ft | 6 mm²AWG 10 | 23.5 A | 30 A | 0.27% |
| C14 · Fuse block IN − → Negative bus bar 2 − | 50 cm1.6 ft | 6 mm²AWG 10 | 23.5 A | — | 0.27% |
| C15 · Fuse block 1 + → Compressor fridge + | 3 m9.8 ft | 6 mm²AWG 10 | 5 A | 15 A | 0.34% |
| C16 · Compressor fridge − → Fuse block 1 − | 3 m9.8 ft | 6 mm²AWG 10 | 5 A | — | 0.34% |
| C17 · Fuse block 2 + → LED lights + | 5 m16.4 ft | 1.5 mm²AWG 16 | 2 A | 3 A | 0.91% |
| C18 · LED lights − → Fuse block 2 − | 5 m16.4 ft | 1.5 mm²AWG 16 | 2 A | — | 0.91% |
| C19 · Fuse block 3 + → Roof fan + | 3 m9.8 ft | 2.5 mm²AWG 13 | 5 A | 7.5 A | 0.82% |
| C20 · Roof fan − → Fuse block 3 − | 3 m9.8 ft | 2.5 mm²AWG 13 | 5 A | — | 0.82% |
| C21 · Fuse block 4 + → Water pump + | 2 m6.6 ft | 2.5 mm²AWG 13 | 6 A | 7.5 A | 0.66% |
| C22 · Water pump − → Fuse block 4 − | 2 m6.6 ft | 2.5 mm²AWG 13 | 6 A | — | 0.66% |
| C23 · Fuse block 5 + → USB-C charging + | 3 m9.8 ft | 2.5 mm²AWG 13 | 5.5 A | 7.5 A | 0.90% |
| C24 · USB-C charging − → Fuse block 5 − | 3 m9.8 ft | 2.5 mm²AWG 13 | 5.5 A | — | 0.90% |
A dash means the cable has no fuse of its own: a negative, or a run protected by the fuse upstream of it. Fuses on a battery post are listed with the battery in the drawing.
How it is wired
01
One way in, one battery
The solar controller and the battery meet at one positive and one negative bus bar, and the fuse block takes its feed from the same pair. While the sun is up the loads run from the panels first and the battery takes the rest; the shunt on the battery negative counts both directions.
02
Fuse at the battery, fuse at each branch
The 80 A terminal fuse on the house battery protects the main cable to the switch and bus bar. The controller output has its own fuse, and every load has a blade fuse in the fuse block sized for its own cable.
03
Connect the battery before the panels
Wire the controller to the battery first, set the lithium profile, and only then close the solar isolator. Disconnect in the reverse order before working on the controller.
04
Leave room for a DC-DC charger
If you later want charging while you drive, a DC-DC charger lands on the same bus bars with its own fuse. Choose bus bars with a spare stud now so that is a two-cable job.
Before you build
Crimp's checks on this drawing: 0 critical, 2 to review. They stay visible when you open it.
- Measure your own cable runs and re-check the sizes in Crimp after changing them.
- Read your panel label: two panels in parallel keep one panel's voltage; check the cold-weather Voc against the controller's 100 V limit.
- Pick fuses and holders with an interrupt rating above the lithium battery's short-circuit current.
- Mount the controller close to the battery so the battery cable stays short.
- warning: Check monitor power: Battery monitor
- info: Check fuse suitability: House battery 100 Ah LiFePO4
A planning example, not an installation certificate. Sizing follows Crimp's published method; check the manufacturer manuals below for your exact parts.
Questions about this system
Is 200W of solar enough for a 100Ah lithium battery?
In summer, about. This drawing uses about 830 Wh on a summer day and the panels put back about 750 Wh with five sun hours, so a full battery drifts down only slowly. In winter, at about 1.5 sun hours, they make about 225 Wh against about 590 Wh of use, and the battery is flat in under three days.
Do I need a DC-DC charger in a campervan?
Not if you camp in summer and park in the sun. Without one, nothing charges the house battery on cloudy days or in winter except a hook-up. A 30 A DC-DC charger adds about 380 Wh for every hour of driving; the 100Ah DC-DC version of this diagram shows that system.
How long will a 100Ah lithium battery run a fridge?
The fridge in this drawing draws 5 A while its compressor runs, about a quarter of the day, so about 360 Wh a day. A 100 Ah LiFePO4 battery holds about 1,000 Wh above a 20 % reserve, so the fridge on its own runs for nearly three days with no sun.
What size fuse do I need between the battery and the fuse block?
In this drawing an 80 A MRBF terminal fuse at the battery protects the 16 mm² (about 5 AWG) main cable, and the cable from the bus bar to the fuse block carries its own fuse. A fuse protects the cable it is on, so it is chosen for that cable, not for the loads.
Should two 100W panels be wired in series or parallel?
This drawing wires them in parallel, which keeps one panel's voltage and adds the currents, and copes better when one panel is shaded. Series doubles the voltage and halves the current, which suits a long cable run; check the controller's 100 V limit at your coldest temperature before changing it.
Manufacturer sources
Reviewed 26 November 2026.
Start from this system instead of a blank page.
Open this diagram in Crimp