Campervan wiring diagram
100Ah lithium campervan wiring diagram with 200W solar & DC-DC charger
This is the system most first van builds end up with: one 100 Ah LiFePO4 battery, two 100 W panels on the roof and a 30 A DC-DC charger that tops the battery up from the alternator while you drive. It runs a 12 V compressor fridge, LED lights, a roof fan, a water pump, USB-C charging and a diesel heater, with no inverter. It suits weekend and holiday trips, and longer stays if you drive most days. It does not suit running a kettle, hair dryer or induction hob.
The wiring diagram
18 components · 30 conductors · 12 V

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.
View full screenRed = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.
What it powers
Each load's draw comes from its catalog entry. The hours are this guide's assumptions; change them to yours.
| Load | Draw | Hours a day | Energy a day | Why |
|---|---|---|---|---|
| Compressor fridge | 60 W | 6 h | 360 Wh | A compressor fridge cycles; about a quarter of the day, more in hot weather. |
| LED lights | 24 W | 4 h | 96 Wh | Evenings. |
| Roof fan | 60 W | 4 hsummer only | 240 Wh | Warm evenings at full speed; lower speeds draw less. |
| Water pump | 72 W | 0.25 h | 18 Wh | About 15 minutes of washing and cooking. |
| USB-C charging | 60 W | 2 h | 120 Wh | A laptop and phones at full 60 W. |
| Diesel heater | 40 W | 8 hwinter only | 320 Wh | Overnight on cold nights; nothing in summer. |
| Total a day | 834 Wh summer 914 Wh winter |
Energy budget
What goes in against what comes out, per day. Solar assumes 5 peak sun hours in summer and 1.5 in winter at 75 % panel-to-battery efficiency; the alternator figure assumes 1 hour of driving.
A summer day
- Solar in
- +750 Wh
- Driving in (1 h)
- +384 Wh
- Used
- −834 Wh
- Net
- +300 Wh
The battery ends the day fuller than it started.
A winter day
- Solar in
- +225 Wh
- Driving in (1 h)
- +384 Wh
- Used
- −914 Wh
- Net
- −305 Wh
The battery loses about 30 % of its usable charge a day; a full battery lasts about 3 days like this.
With no charging at all, the 1,024 Wh above a 20 % reserve lasts about 1.1 days at the larger daily use. In Crimp, switch loads on and off in the drawing to see the live current and runtime.
Parts list
18 parts. Each links to its Crimp page with the manufacturer's ratings and installation notes.
- Vehicle starter batteryPlanning placeholder12 V · 80 Ah
- DC-DC charger 30 AOrion-Tr Smart 12/12-3030 A rated / planning output
- Roof solar panel 100 W 1RNG-100D-SS18.6 V · 5.38 A rated / planning output · 100 W · 22.3 V STC Voc
- Roof solar panel 100 W 2RNG-100D-SS18.6 V · 5.38 A rated / planning output · 100 W · 22.3 V STC Voc
- Solar isolatorPlanning placeholder
- Solar charge controllerSmartSolar 100/2020 A rated / planning output
- House battery 100 Ah LiFePO4RBT12100LFP-M12.8 V · 100 Ah
- Battery monitorSmartShunt 500A/50mV (IP21)
- Main battery switchPlanning placeholder
- Positive bus barPlanning placeholder
- Negative bus barPlanning placeholder
- Fuse block5025
- Compressor fridgeCRX-505 A load allowance
- LED lightsPlanning placeholder2 A load allowance · 24 W
- Roof fanMaxxfan Deluxe 7500K5 A load allowance
- Water pumpUniversal6 A load allowance
- USB-C chargingPlanning placeholder5.5 A load allowance · 60 W
- Diesel heaterAirtronic D44 A load allowance · 40 W
Cable and fuse sizes
Sized by Crimp's ABYC E-11 based engine for these lengths. Lengths are one way; AWG is the approximate counterpart of the metric size.
| Connection | Length | Wire | Design current | Fuse | Drop |
|---|---|---|---|---|---|
| C1 · Vehicle starter battery + → DC-DC charger 30 A IN + | 3 m9.8 ft | 16 mm²AWG 6manufacturer size | 36.8 A | — | 1.01% |
| C2 · Vehicle starter battery − → DC-DC charger 30 A IN − | 3 m9.8 ft | 16 mm²AWG 6manufacturer size | 36.8 A | — | 1.01% |
| C3 · DC-DC charger 30 A OUT + → Positive bus bar + | 1 m3.3 ft | 10 mm²AWG 8manufacturer size | 30 A | 60 A | 0.41% |
| C4 · DC-DC charger 30 A OUT − → Negative bus bar 1 − | 1 m3.3 ft | 10 mm²AWG 8manufacturer size | 30 A | — | 0.41% |
| C5 · Roof solar panel 100 W 1 + → Solar isolator IN + | 4 m13.1 ft | 2.5 mm²AWG 13 | 5.4 A | 7.5 A | 0.81% |
| C6 · Roof solar panel 100 W 2 + → Solar isolator IN + | 4 m13.1 ft | 2.5 mm²AWG 13 | 5.4 A | 7.5 A | 0.81% |
| C7 · Roof solar panel 100 W 1 − → Solar isolator IN − | 4 m13.1 ft | 1.5 mm²AWG 16 | 5.4 A | — | 1.35% |
| C8 · Roof solar panel 100 W 2 − → Solar isolator IN − | 4 m13.1 ft | 1.5 mm²AWG 16 | 5.4 A | — | 1.35% |
| C9 · Solar isolator OUT + → Solar charge controller PV + | 50 cm1.6 ft | 1.5 mm²AWG 16 | 10.8 A | 15 A | 0.34% |
| C10 · Solar isolator OUT − → Solar charge controller PV − | 50 cm1.6 ft | 1.5 mm²AWG 16 | 10.8 A | — | 0.34% |
| C11 · Solar charge controller BATT + → Positive bus bar 1 + | 1 m3.3 ft | 4 mm²AWG 11 | 20 A | 25 A | 0.68% |
| C12 · Solar charge controller BATT − → Negative bus bar 2 − | 1 m3.3 ft | 2.5 mm²AWG 13 | 20 A | — | 1.09% |
| C13 · House battery 100 Ah LiFePO4 + → Main battery switch A | 30 cm1.0 ft | 16 mm²AWG 6manufacturer size | 50 A | — | 0.13% |
| C14 · Main battery switch B → Positive bus bar 2 + | 30 cm1.0 ft | 16 mm²AWG 6manufacturer size | 50 A | — | 0.13% |
| C15 · House battery 100 Ah LiFePO4 − → Battery monitor BATT − | 30 cm1.0 ft | 16 mm²AWG 6manufacturer size | 50 A | — | 0.13% |
| C16 · Battery monitor LOAD − → Negative bus bar 4 − | 30 cm1.0 ft | 16 mm²AWG 6manufacturer size | 50 A | — | 0.13% |
| C17 · Positive bus bar 3 + → Fuse block IN + | 50 cm1.6 ft | 6 mm²AWG 10 | 27.5 A | 35 A | 0.31% |
| C18 · Fuse block IN − → Negative bus bar 3 − | 50 cm1.6 ft | 6 mm²AWG 10 | 27.5 A | — | 0.31% |
| C19 · Fuse block 1 + → Compressor fridge + | 3 m9.8 ft | 6 mm²AWG 10 | 5 A | 15 A | 0.34% |
| C20 · Compressor fridge − → Fuse block 1 − | 3 m9.8 ft | 6 mm²AWG 10 | 5 A | — | 0.34% |
| C21 · Fuse block 2 + → LED lights + | 5 m16.4 ft | 1.5 mm²AWG 16 | 2 A | 3 A | 0.91% |
| C22 · LED lights − → Fuse block 2 − | 5 m16.4 ft | 1.5 mm²AWG 16 | 2 A | — | 0.91% |
| C23 · Fuse block 3 + → Roof fan + | 3 m9.8 ft | 2.5 mm²AWG 13 | 5 A | 7.5 A | 0.82% |
| C24 · Roof fan − → Fuse block 3 − | 3 m9.8 ft | 2.5 mm²AWG 13 | 5 A | — | 0.82% |
| C25 · Fuse block 4 + → Water pump + | 2 m6.6 ft | 2.5 mm²AWG 13 | 6 A | 7.5 A | 0.66% |
| C26 · Water pump − → Fuse block 4 − | 2 m6.6 ft | 2.5 mm²AWG 13 | 6 A | — | 0.66% |
| C27 · Fuse block 5 + → USB-C charging + | 3 m9.8 ft | 2.5 mm²AWG 13 | 5.5 A | 7.5 A | 0.90% |
| C28 · USB-C charging − → Fuse block 5 − | 3 m9.8 ft | 2.5 mm²AWG 13 | 5.5 A | — | 0.90% |
| C29 · Fuse block 6 + → Diesel heater + | 2 m6.6 ft | 1.5 mm²AWG 16 | 4 A | 7.5 A | 0.73% |
| C30 · Diesel heater − → Fuse block 6 − | 2 m6.6 ft | 1.5 mm²AWG 16 | 4 A | — | 0.73% |
A dash means the cable has no fuse of its own: a negative, or a run protected by the fuse upstream of it. Fuses on a battery post are listed with the battery in the drawing.
How it is wired
01
Three ways in, one battery
The solar controller, the DC-DC charger and the battery all meet at one positive and one negative bus bar. Whatever charges, the loads take first and the battery gets the rest; the shunt on the battery negative counts both directions.
02
Fuse at every source
Each wire that a battery can push current into gets a fuse at that battery's end: the 60 A fuse at the vehicle battery, the 80 A terminal fuse on the house battery and a fuse on each charger output. Every load has its own blade fuse in the fuse block.
03
Keep the charger isolated
This Orion-Tr is the isolated model, so its input negative goes back to the vehicle battery and its output negative to the house bus bar. Do not join them unless your vehicle and installation call for a shared ground.
04
Switch the solar off first
The solar isolator lets you disconnect the panels before working on the controller. Connect the controller to the battery before the panels, and set the lithium profile before switching the solar on.
Before you build
Crimp's checks on this drawing: 0 critical, 4 to review. They stay visible when you open it.
- Measure your own cable runs and re-check the sizes in Crimp after changing them.
- Read your panel label: two panels in parallel keep one panel's voltage; check the cold-weather Voc against the controller's 100 V limit.
- Set the DC-DC input current limit if your alternator cannot spare 30 A plus losses.
- Pick fuses and holders with an interrupt rating above the lithium battery's short-circuit current.
- warning: DC-DC charger 30 A: verify manufacturer wiring
- warning: Check monitor power: Battery monitor
- info: Check fuse suitability: House battery 100 Ah LiFePO4
- info: Check fuse suitability: Vehicle starter battery
A planning example, not an installation certificate. Sizing follows Crimp's published method; check the manufacturer manuals below for your exact parts.
Questions about this system
Is 100Ah lithium enough for a campervan?
For a fridge, lights, fan, diesel heater and phone or laptop charging, yes, if something recharges it every day. This drawing uses about 850–900 Wh a day, and a 100 Ah LiFePO4 battery holds about 1,000 Wh above a 20 % reserve, so a full battery alone lasts about a day. It is not enough for an induction hob, kettle or electric heating.
Do I need a DC-DC charger if I have 200W of solar?
On a sunny summer day 200 W puts back about 750 Wh, most of what this system uses. On a winter day it is closer to 225 Wh, so without alternator charging a full battery is flat in a day or two. The 30 A DC-DC charger turns an hour of driving into about 380 Wh, over a third of the usable battery.
What size fuse goes between the house battery and the bus bar?
In this drawing an 80 A MRBF terminal fuse protects a 16 mm² (about 5 AWG) main cable. The fuse is chosen to protect that cable, not to match the loads; change the cable and the fuse changes with it.
Can I connect the DC-DC charger negative to the chassis?
The isolated Orion-Tr Smart keeps its input and output negatives separate, so this drawing returns each one to its own battery. Many installations ground through the chassis; use the earth points your vehicle maker approves, and keep the conductor sizes the manual asks for.
Should the solar panels be wired in series or parallel?
This drawing wires the two 100 W panels in parallel, which keeps the voltage of one panel and adds the currents, and tolerates shade on one panel better. Series doubles the voltage, which suits longer cable runs; check the controller's voltage limit if you change it.
Why is the fridge cable thicker than its current suggests?
A fridge's electronics shut it off when the voltage at the fridge drops too far, so Crimp sizes its circuit to the 3 % voltage-drop table rather than ampacity alone. Over a 3 m run that needs a thicker cable than 5 A would.
Manufacturer sources
Reviewed 26 November 2026.
Start from this system instead of a blank page.
Open this diagram in Crimp