Campervan wiring diagram
200Ah lithium campervan wiring diagram with 400W solar, DC-DC & 2000W inverter
This is the usual next step from a weekend van: a 200 Ah LiFePO4 battery, 400 W of solar, a 50 A DC-DC charger and a 2000 W pure-sine inverter for mains appliances. The inverter takes its own heavy cable and fuse from the bus bar, never a fuse-block slot. It suits people who work from the van and want to cook on electricity. With 20 minutes of induction cooking a day it roughly breaks even on a sunny summer day with an hour's drive; in winter it needs longer drives or a hook-up. The energy budget below shows the numbers.
The wiring diagram
20 components · 35 conductors · 12 V

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.
View full screenRed = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.
What it powers
Each load's draw comes from its catalog entry. The hours are this guide's assumptions; change them to yours.
| Load | Draw | Hours a day | Energy a day | Why |
|---|---|---|---|---|
| Compressor fridge | 66 W | 6 h | 396 Wh | A compressor fridge cycles; about a quarter of the day, more in hot weather. |
| LED lights | 24 W | 4 h | 96 Wh | Evenings. |
| Roof fan | 60 W | 4 hsummer only | 240 Wh | Warm evenings at full speed; lower speeds draw less. |
| Water pump | 72 W | 0.25 h | 18 Wh | About 15 minutes of washing and cooking. |
| USB-C charging | 60 W | 2 h | 120 Wh | Phones and a tablet at full 60 W. |
| Starlink Mini | 30 W | 8 h | 240 Wh | A working day online. |
| Diesel heater | 40 W | 8 hwinter only | 320 Wh | Overnight on cold nights; nothing in summer. |
| Induction hob (AC, via the inverter) | 1800 W | 20 min | 594 Wh | AC energy; the battery supplies it divided by 85 % inverter efficiency. |
| Coffee machine (AC, via the inverter) | 1200 W | 6 min | 120 Wh | AC energy; the battery supplies it divided by 85 % inverter efficiency. |
| Laptop (AC, via the inverter) | 65 W | 4 h | 260 Wh | AC energy; the battery supplies it divided by 85 % inverter efficiency. |
| Inverter loads, from the battery | 1,146 Wh | |||
| Total a day | 2,256 Wh summer 2,336 Wh winter |
Energy budget
What goes in against what comes out, per day. Solar assumes 5 peak sun hours in summer and 1.5 in winter at 75 % panel-to-battery efficiency; the alternator figure assumes 1 hour of driving.
A summer day
- Solar in
- +1,500 Wh
- Driving in (1 h)
- +640 Wh
- Used
- −2,256 Wh
- Net
- −116 Wh
The battery loses about 6 % of its usable charge a day; a full battery lasts about 17 days like this.
A winter day
- Solar in
- +450 Wh
- Driving in (1 h)
- +640 Wh
- Used
- −2,336 Wh
- Net
- −1,246 Wh
The battery loses about 61 % of its usable charge a day; a full battery lasts about 1 day like this.
With no charging at all, the 2,048 Wh above a 20 % reserve lasts about 0.9 days at the larger daily use. In Crimp, switch loads on and off in the drawing to see the live current and runtime.
Parts list
20 parts. Each links to its Crimp page with the manufacturer's ratings and installation notes.
- Vehicle starter batteryPlanning placeholder12 V · 80 Ah
- DC-DC charger 50 ADCC50S50 A rated / planning output
- Roof solar panel 200 W 1RSP200D22.6 V · 8.85 A rated / planning output · 200 W · 27 V STC Voc
- Roof solar panel 200 W 2RSP200D22.6 V · 8.85 A rated / planning output · 200 W · 27 V STC Voc
- Solar isolatorPlanning placeholder
- Solar charge controllerSmartSolar 100/5050 A rated / planning output
- House battery 200 Ah LiFePO4RBT12200LFP-M12.8 V · 200 Ah
- Battery monitorSmartShunt 500A/50mV (IP21)
- Main battery switchPlanning placeholder
- Positive bus bar2104
- Negative bus bar2127
- Inverter 2000 WRNG-INVT-2000-12V-P2-US12 V · 196.1 A load allowance · 2000 W
- Fuse block5026
- Compressor fridgeCRX-655.5 A load allowance · 66 W
- LED lightsPlanning placeholder2 A load allowance · 24 W
- Roof fanMaxxfan Deluxe 7500K5 A load allowance
- Water pumpUniversal6 A load allowance
- USB-C chargingPlanning placeholder5.5 A load allowance · 60 W
- Starlink MiniStarlink Mini12 V · 2.5 A load allowance · 30 W
- Diesel heaterAirtronic D44 A load allowance · 40 W
Cable and fuse sizes
Sized by Crimp's ABYC E-11 based engine for these lengths. Lengths are one way; AWG is the approximate counterpart of the metric size.
| Connection | Length | Wire | Design current | Fuse | Drop |
|---|---|---|---|---|---|
| C1 · Vehicle starter battery + → DC-DC charger 50 A ALT + | 3 m9.8 ft | 16 mm²AWG 6manufacturer size | 59.3 A | — | 1.62% |
| C2 · Vehicle starter battery − → Negative bus bar − 2 | 3 m9.8 ft | 16 mm²AWG 6manufacturer size | 59.3 A | — | 1.52% |
| C3 · DC-DC charger 50 A OUT + → Positive bus bar 1 | 1 m3.3 ft | 16 mm²AWG 6manufacturer size | 50 A | 65 A | 0.43% |
| C4 · DC-DC charger 50 A NEG − → Negative bus bar − 3 | 1 m3.3 ft | 16 mm²AWG 6manufacturer size | 9.3 A | — | 0.08% |
| C5 · Roof solar panel 200 W 1 + → Solar isolator IN + | 4 m13.1 ft | 4 mm²AWG 11 | 8.8 A | 15 A | 0.69% |
| C6 · Roof solar panel 200 W 2 + → Solar isolator IN + | 4 m13.1 ft | 4 mm²AWG 11 | 8.8 A | 15 A | 0.69% |
| C7 · Roof solar panel 200 W 1 − → Solar isolator IN − | 4 m13.1 ft | 2.5 mm²AWG 13 | 8.8 A | — | 1.10% |
| C8 · Roof solar panel 200 W 2 − → Solar isolator IN − | 4 m13.1 ft | 2.5 mm²AWG 13 | 8.8 A | — | 1.10% |
| C9 · Solar isolator OUT + → Solar charge controller PV + | 50 cm1.6 ft | 1.5 mm²AWG 16 | 17.7 A | 25 A | 0.46% |
| C10 · Solar isolator OUT − → Solar charge controller PV − | 50 cm1.6 ft | 1.5 mm²AWG 16 | 17.7 A | — | 0.46% |
| C11 · Solar charge controller BATT + → Positive bus bar 2 | 1 m3.3 ft | 10 mm²AWG 8manufacturer size | 50 A | 60 A | 0.68% |
| C12 · Solar charge controller BATT − → Negative bus bar − 4 | 1 m3.3 ft | 10 mm²AWG 8 | 50 A | — | 0.68% |
| C13 · House battery 200 Ah LiFePO4 + → Main battery switch A | 30 cm1.0 ft | 70 mm²AWG 2/0 | 226.4 A | — | 0.13% |
| C14 · Main battery switch B → Positive bus bar 3 | 30 cm1.0 ft | 70 mm²AWG 2/0 | 226.4 A | — | 0.13% |
| C15 · House battery 200 Ah LiFePO4 − → Battery monitor BATT − | 30 cm1.0 ft | 70 mm²AWG 2/0 | 226.4 A | — | 0.13% |
| C16 · Battery monitor LOAD − → Negative bus bar 5 − | 30 cm1.0 ft | 70 mm²AWG 2/0 | 226.4 A | — | 0.13% |
| C17 · Positive bus bar 4 → Inverter 2000 W DC + | 1 m3.3 ft | 70 mm²AWG 2/0manufacturer size | 196.1 A | 250 A | 0.38% |
| C18 · Inverter 2000 W DC − → Negative bus bar 6 − | 1 m3.3 ft | 70 mm²AWG 2/0 | 196.1 A | — | 0.38% |
| C19 · Inverter 2000 W GROUND − → Negative bus bar 7 − | 1 m3.3 ft | 1.5 mm²AWG 16 | 0 A | — | 0.00% |
| C20 · Positive bus bar 4 → Fuse block IN + | 50 cm1.6 ft | 10 mm²AWG 8 | 30.3 A | 40 A | 0.21% |
| C21 · Fuse block IN − → Negative bus bar 4 − | 50 cm1.6 ft | 6 mm²AWG 10 | 30.3 A | — | 0.35% |
| C22 · Fuse block 1 + → Compressor fridge + | 3 m9.8 ft | 6 mm²AWG 10 | 5.5 A | 15 A | 0.38% |
| C23 · Compressor fridge − → Fuse block 1 − | 3 m9.8 ft | 6 mm²AWG 10 | 5.5 A | — | 0.38% |
| C24 · Fuse block 2 + → LED lights + | 5 m16.4 ft | 1.5 mm²AWG 16 | 2 A | 3 A | 0.91% |
| C25 · LED lights − → Fuse block 2 − | 5 m16.4 ft | 1.5 mm²AWG 16 | 2 A | — | 0.91% |
| C26 · Fuse block 3 + → Roof fan + | 3 m9.8 ft | 2.5 mm²AWG 13 | 5 A | 7.5 A | 0.82% |
| C27 · Roof fan − → Fuse block 3 − | 3 m9.8 ft | 2.5 mm²AWG 13 | 5 A | — | 0.82% |
| C28 · Fuse block 4 + → Water pump + | 2 m6.6 ft | 2.5 mm²AWG 13 | 6 A | 7.5 A | 0.66% |
| C29 · Water pump − → Fuse block 4 − | 2 m6.6 ft | 2.5 mm²AWG 13 | 6 A | — | 0.66% |
| C30 · Fuse block 5 + → USB-C charging + | 3 m9.8 ft | 2.5 mm²AWG 13 | 5.5 A | 7.5 A | 0.90% |
| C31 · USB-C charging − → Fuse block 5 − | 3 m9.8 ft | 2.5 mm²AWG 13 | 5.5 A | — | 0.90% |
| C32 · Fuse block 6 + → Starlink Mini + | 3 m9.8 ft | 1.5 mm²AWG 16 | 2.3 A | 3 A | 0.64% |
| C33 · Starlink Mini − → Fuse block 6 − | 3 m9.8 ft | 1.5 mm²AWG 16 | 2.3 A | — | 0.64% |
| C34 · Fuse block 7 + → Diesel heater + | 2 m6.6 ft | 1.5 mm²AWG 16 | 4 A | 7.5 A | 0.73% |
| C35 · Diesel heater − → Fuse block 7 − | 2 m6.6 ft | 1.5 mm²AWG 16 | 4 A | — | 0.73% |
A dash means the cable has no fuse of its own: a negative, or a run protected by the fuse upstream of it. Fuses on a battery post are listed with the battery in the drawing.
How it is wired
01
The inverter gets its own branch
At 2000 W the inverter draws close to 200 A from a 12 V battery. It connects to the bus bar through its own 250 A fuse and the heaviest cable in the van, kept short. The fuse block feeds only the small 12 V circuits.
02
One shared negative
The DCC50S has a single NEG− terminal for every battery, so the vehicle battery's negative, the charger and the house battery all meet at the negative bus bar. The shunt sits between the house battery and that bar, so it counts every amp in and out.
03
Mind the battery's limit
The battery's BMS allows 200 A continuous. The inverter at full output plus the 12 V loads can exceed it, which trips the BMS rather than any fuse. Cook on the hob with the other big loads off, or step up to two batteries.
04
Two chargers, one bank
The solar controller and the DC-DC charger both land on the positive bus bar with their own fuses. Set both to the same lithium charge voltage so neither stops early.
Before you build
Crimp's checks on this drawing: 0 critical, 6 to review. They stay visible when you open it.
- Measure the inverter cable run; every extra 50 cm adds voltage drop at 200 A. Re-check its size in Crimp.
- Use a fuse at the battery with an interrupt rating suited to a 200 Ah lithium bank, such as class T.
- Check the two 200 W panels' cold-weather Voc in parallel against the controller's 100 V limit.
- Check that your alternator can spare the DC-DC charger's input current, and connect the IGN wire on a smart-alternator vehicle.
- The inverter's AC outlets and any AC wiring are not drawn: protect AC circuits as the inverter manual and local rules require.
- warning: Connected demand exceeds battery discharge ratings
- warning: Check monitor power: Battery monitor
- info: AC installation checks remain
- info: Check inverter disconnection
- info: Check fuse suitability: House battery 200 Ah LiFePO4
- info: Check fuse suitability: Vehicle starter battery
A planning example, not an installation certificate. Sizing follows Crimp's published method; check the manufacturer manuals below for your exact parts.
Questions about this system
Can a 200Ah lithium battery run a 2000W inverter?
It can supply the current: a 2000 W load draws close to 200 A, which is the battery's continuous rating. What limits it is energy, not current. Twenty minutes of an 1800 W hob uses about 700 Wh from the battery once inverter losses are counted, about a third of the usable capacity. Running the hob with the other big loads on can also exceed the BMS's 200 A, which Crimp flags in the checks below.
What size cable does a 2000W inverter need on 12V?
Crimp sizes the 1 m inverter run in this drawing for its 196 A planning current (2000 W at 85 % efficiency from 12 V) and the 250 A fuse the manual asks for. Read the exact size in the cable table below; a longer run needs a thicker cable to keep the voltage drop down.
Should the inverter connect to the fuse block?
No. Blade fuse blocks are rated for tens of amps. The inverter connects to the positive bus bar or battery through its own fuse and cable, and the fuse block feeds only the small 12 V circuits.
Is 400W of solar enough for a 200Ah battery?
On a sunny summer day 400 W puts back about 1,500 Wh; with an hour of driving (about 640 Wh from the DC-DC charger) that nearly matches this drawing's 2,250 Wh day. In winter the panels give closer to 450 Wh, so plan on longer drives, a hook-up or less electric cooking.
Why a 50A DC-DC charger instead of 30A?
A 200 Ah lithium battery accepts 50 A easily (its manual allows 100 A charging), and the larger charger refills it in roughly 60 % of the driving time a 30 A unit needs. Check that your alternator can spare the input current, which is higher than 50 A because of conversion losses; that is why Renogy asks for a 75 A input fuse.
Do I need a battery monitor?
With an inverter, yes in practice. A lithium battery's voltage barely changes until it is nearly empty, so the shunt's count of amp-hours is the only reliable fuel gauge. It sits on the battery negative so every charger and load passes through it.