Boat wiring diagram
Bilge pump wiring diagram: automatic 3-wire and 2-wire with float switch
An automatic bilge pump must keep working when the boat is switched off, so its automatic feed comes from the battery side of the main switch, through its own fuse close to the battery. A manual switch on the panel adds an override for running the pump by hand. On a 3-wire automatic pump such as the Rule-Mate, brown is the automatic feed, brown/white the manual feed and black the negative. On a 2-wire pump, a separate float switch sits in the positive wire and the manual switch is wired in parallel with it. Use the fuse the pump's manual gives: 7.5 A for the Rule-Mate 1100.
3-wire automatic pump (Rule-Mate 1100)
Brown goes to the always-on fuse, brown/white to the manual switch on the switched fuse block, black to negative. The pump's own sensor decides when to run.
6 components · 8 conductors

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.
View full screenRed = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.
2-wire pump with a float switch
The float switch sits in the pump's positive, fed from the always-on fuse. The manual switch is in parallel with the float: either one runs the pump.
7 components · 9 conductors

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.
View full screenRed = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.
Rule 3-wire automatic pump: wire colours
From Rule's Rule-Mate 500–1100 manual. Check the label on your pump: other makes use other colours.
| Wire | What it does | Connect it to |
|---|---|---|
| Brown | Automatic positive | The always-on fused supply, from the battery side of the main switch |
| Brown/white | Manual override positive | The manual position of the panel switch; seal it off if you fit no override |
| Black | Negative | The negative bus |
Never join brown and brown/white: that bypasses the pump's sensor and leaves it running until the battery is flat or the motor burns out.
Step by step
01
Plan the always-on feed
Take a fused supply from the battery side of the main switch, close to the battery, so the pump keeps working with the boat switched off. Blue Sea's split fuse blocks have a separate 24-hour section for exactly this.
02
Fit the pump's fuse
Use the rating in the pump's manual: Rule specifies 7.5 A for the Rule-Mate 1100 and advises against a circuit breaker. The 2-wire drawing uses 5 A for a 3.5 A pump.
03
Wire the automatic feed
On a 3-wire pump, brown goes to the always-on fuse. On a 2-wire pump, the always-on fuse feeds one lead of the float switch and the other float lead goes to the pump's positive.
04
Add the manual override
From a slot on the switched fuse block, run a wire to a panel switch, and from the switch to the pump: brown/white on a 3-wire pump, or the pump's positive (in parallel with the float) on a 2-wire pump.
05
Return the negative
Take the pump's black or negative lead to the negative bus. Make every splice above the highest bilge water, with sealed heat-shrink connectors.
06
Test both modes
With the main switch off, lift the float or pour water into the bilge and check the pump starts and stops. Then test the manual switch, and switch it back off. Rule asks for at least 10.5 V at the running pump.
Cable and fuse sizes
Sized by Crimp's ABYC E-11 based engine for the lengths shown. Lengths are one way; AWG is the approximate counterpart of the metric size.
3-wire automatic pump (Rule-Mate 1100)
| Connection | Length | Wire | Design current | Fuse | Drop |
|---|---|---|---|---|---|
| C1 · Battery + → Always-on pump fuse 7.5 A IN + | 10 cm0.3 ft | 4 mm²AWG 11 | 4.8 A | — | 0.02% |
| C2 · Battery + → Main battery switch A | 50 cm1.6 ft | 4 mm²AWG 11 | 4.8 A | — | 0.09% |
| C3 · Main battery switch B → Switched fuse block IN + | 50 cm1.6 ft | 4 mm²AWG 11 | 4.8 A | — | 0.09% |
| C4 · Switched fuse block 1 + → Manual pump switch A | 50 cm1.6 ft | 4 mm²AWG 11set size | 4.8 A | 7.5 A | 0.09% |
| C5 · Always-on pump fuse 7.5 A OUT + → Automatic bilge pump (3-wire) Auto + (brown) | 4 m13.1 ft | 4 mm²AWG 11set size | 4.8 A | 7.5 A | 0.70% |
| C6 · Manual pump switch B → Automatic bilge pump (3-wire) Manual + (brown/white) | 4 m13.1 ft | 4 mm²AWG 11 | 4.8 A | — | 0.70% |
| C7 · Automatic bilge pump (3-wire) − (black) → Switched fuse block 1 − | 4 m13.1 ft | 4 mm²AWG 11 | 4.8 A | — | 0.70% |
| C8 · Switched fuse block IN − → Battery − | 1 m3.3 ft | 4 mm²AWG 11 | 4.8 A | — | 0.18% |
2-wire pump with a float switch
| Connection | Length | Wire | Design current | Fuse | Drop |
|---|---|---|---|---|---|
| C1 · Battery + → Always-on pump fuse 5 A IN + | 10 cm0.3 ft | 1.5 mm²AWG 16 | 3.5 A | — | 0.03% |
| C2 · Battery + → Main battery switch A | 50 cm1.6 ft | 2.5 mm²AWG 13 | 3.5 A | — | 0.10% |
| C3 · Main battery switch B → Switched fuse block IN + | 50 cm1.6 ft | 2.5 mm²AWG 13 | 1.8 A | — | 0.05% |
| C4 · Switched fuse block 1 + → Manual pump switch A | 50 cm1.6 ft | 1.5 mm²AWG 16set size | 3.5 A | 5 A | 0.17% |
| C5 · Always-on pump fuse 5 A OUT + → Float switch Supply + | 50 cm1.6 ft | 1.5 mm²AWG 16set size | 3.5 A | 5 A | 0.17% |
| C6 · Float switch Pump + → Bilge pump (2-wire) + | 3 m9.8 ft | 1.5 mm²AWG 16 | 3.5 A | — | 1.02% |
| C7 · Manual pump switch B → Bilge pump (2-wire) + | 3 m9.8 ft | 1.5 mm²AWG 16 | 3.5 A | — | 1.02% |
| C8 · Bilge pump (2-wire) − → Switched fuse block 1 − | 4 m13.1 ft | 1.5 mm²AWG 16 | 3.5 A | — | 1.36% |
| C9 · Switched fuse block IN − → Battery − | 1 m3.3 ft | 1.5 mm²AWG 16 | 3.5 A | — | 0.34% |
A dash means the cable has no fuse of its own: a negative, a cable past a switch, or a run protected by the fuse upstream of it. Fuses on a battery post or in an inline holder are drawn on the diagram.
Common mistakes
Crimp's checks on these drawings: 0 critical, 6 to review. They stay visible when you open it.
- Feeding the automatic pump through the main switch. Switch off when you leave and the pump stops guarding the boat.
- Joining brown and brown/white on a 3-wire pump. The pump runs all the time.
- Fitting a bigger fuse because it blows. Check the strainer, hose and float first; the fuse protects the wire.
- Splicing below the waterline in the bilge. Water creeps into the joint and corrodes it.
- Leaving the manual switch on. The override runs the pump dry; use a momentary switch if you tend to forget.
- warning: Check fuse suitability: Battery (3-wire automatic pump (Rule-Mate 1100))
- warning: Cable sizing needs checking (3-wire automatic pump (Rule-Mate 1100))
- warning: No charging source (3-wire automatic pump (Rule-Mate 1100))
- warning: Check fuse suitability: Battery (2-wire pump with a float switch)
- warning: Cable sizing needs checking (2-wire pump with a float switch)
- warning: No charging source (2-wire pump with a float switch)
A planning example, not an installation certificate. Sizing follows Crimp's published method; check the manufacturer documents below for your exact parts.
Questions
How do I wire a 3-wire bilge pump?
On a Rule automatic pump, brown is the automatic feed and goes to an always-on fused supply from the battery side of the main switch. Brown/white is the manual override and goes to the manual position of a panel switch. Black is negative and goes to the negative bus. If you don't want a manual override, seal the brown/white wire on its own.
Should a bilge pump be wired directly to the battery?
The automatic feed should be, through its own fuse close to the battery and not through the main battery switch, so the pump runs when the boat is switched off. The manual override can come from the switched panel.
What size fuse for a bilge pump?
The one the pump's manual gives. Rule specifies a 7.5 A fuse for the Rule-Mate 1100, which draws 3.8 A at 12 V and 4.8 A at 13.6 V. The fuse protects the wire; a pump that blows its fuse needs checking, not a bigger fuse.
How do I wire a float switch to a bilge pump?
Put the float switch in the pump's positive wire: the always-on fused supply to one float lead, the other float lead to the pump's positive. The pump's negative goes to the negative bus. Rule rates its Rule-A-Matic 35A float for 14 A at 12 V; the 35A is the product name, not its current rating.
What is a 3-way bilge pump switch?
A panel switch with Auto, Off and Manual positions. It does the job of the always-on feed and the manual switch in these drawings in one part. Some boats instead wire the automatic feed straight to the battery and fit only an on/off manual switch, so the automatic mode can never be switched off by accident.
What size wire does a bilge pump need?
Enough to keep the voltage at the running pump high: Rule asks for at least 10.5 V. Crimp treats a bilge pump as a critical circuit and sizes it to the 3 % voltage-drop table ABYC E-11 uses for bilge blowers, so long runs need thicker wire than the current alone suggests. With these lengths Crimp sizes the Rule-Mate's circuit at 4 mm²; open the drawing and enter your own runs.
Sources
Reviewed 26 November 2026.
Draw your own circuit, with every wire and fuse sized.
Start from this diagram