Dometic Penguin II 13.5K RV Air Conditioner / Heat Pump connections

Review the Dometic Penguin II 13.5K RV Air Conditioner / Heat Pump catalog ratings, AC connection points and installation notes, then add the part to your Crimp diagram.

Connection overview

Penguin II 13.5K connections.

See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.

Dometic Penguin II 13.5K RV Air Conditioner / Heat Pump connection overview with 1 components: Penguin II 13.5K. 0 cable connections. Crossings are not junctions.Dometic Penguin II 13.5K RV Air Conditioner / Heat Pump. Mains-terminal overview for the 120 V Penguin II 651815C75X heat pump. Its required 20 A time-delay protection is not its operating current. The complete installation also needs the model-specific thermostat and controls; compressor startup and inverter/battery runtime are not simulated. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.Penguin II 13.5K
Dometic Penguin II 13.5K RV Air Conditioner / Heat Pump connection overview with 1 components: Penguin II 13.5K. 0 cable connections. Crossings are not junctions.Mains-terminal overview for the 120 V Penguin II 651815C75X heat pump. Its required 20 A time-delay protection is not its operating current. The complete installation also needs the model-specific thermostat and controls; compressor startup and inverter/battery runtime are not simulated. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.
Edit this connection overview

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Dometic Penguin II 13,500 BTU RV air conditioner / heat pump, 651815C75X model group, 120 V AC, 60 Hz. Manual rated compressor current is 12.7 A and fan current 2.6 A. The required 20 A time-delay fuse or circuit breaker is a protection rating, not operating draw. The manual specifies at least 12 AWG copper up to 24 ft; longer runs require separate sizing. Only mains L/N/ground connections are represented. Thermostat/control wiring, compressor startup, cycling and inverter/battery runtime effects are not simulated. Check the full model suffix on the installed unit.

The map identifies line, neutral and protective-earth connections. This page does not calculate an AC cable size or protection rating.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

SUPPLY L

neutral · input

—

SUPPLY N

neutral · input

—

GROUND

ground · input

—

A dash means a current rating is not specified here.

Sources and connection guidance

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

AC planning boundary. The drawing identifies conductors and connection points; supported switching states show contact continuity only. Crimp does not calculate AC load flow or verify fault protection, leakage trips, source isolation or grounding. This overview does not calculate cable sizes or validate protective devices. Follow the complete manufacturer installation instructions.