Campervan wiring diagram
24V campervan wiring diagram with 200Ah lithium and 600W solar
A 24 V house system halves the current for the same power, so cables are thinner and solar strings run at a higher voltage. This drawing makes 24 V from two 12.8 V 200 Ah LiFePO4 batteries in series, which gives 200 Ah at 25.6 V, about 5,100 Wh. Three 200 W panels in series feed a 150/35 solar controller. The vehicle stays 12 V, so a 12/24 Orion-Tr Smart steps its alternator up to charge the house battery while driving. The fridge, Starlink and USB-C run straight from 24 V. Lights, the water pump and the diesel heater only come in 12 V, so a 24/12 converter feeds them from a second fuse block.
The wiring diagram
22 components · 35 conductors · 12 V

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.
View full screenRed = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.
What it powers
Each load's draw comes from its catalog entry. The hours are this guide's assumptions; change them to yours.
| Load | Draw | Hours a day | Energy a day | Why |
|---|---|---|---|---|
| Compressor fridge | 66 W | 6 h | 396 Wh | A compressor fridge cycles; about a quarter of the day. |
| Starlink Mini | 30 W | 8 h | 240 Wh | A working day online. |
| USB-C charging | 60 W | 3 h | 180 Wh | A laptop and phones at full 60 W. |
| Diesel heater 12 V | 40 W | 10 hwinter only | 400 Wh | Evening and night at its full 40 W; lower stages draw less. |
| LED lights 12 V | 24 W | 5 h | 120 Wh | Evenings. |
| Water pump 12 V | 72 W | 0.25 h | 18 Wh | About 15 minutes of washing and cooking. |
| Total a day | 954 Wh summer 1,354 Wh winter |
Energy budget
What goes in against what comes out, per day. Solar assumes 5 peak sun hours in summer and 1.5 in winter at 75 % panel-to-battery efficiency; the alternator figure assumes 1 hour of driving.
A summer day
- Solar in
- +2,250 Wh
- Driving in (1 h)
- +256 Wh
- Used
- −954 Wh
- Net
- +1,552 Wh
The battery ends the day fuller than it started.
A winter day
- Solar in
- +675 Wh
- Driving in (1 h)
- +256 Wh
- Used
- −1,354 Wh
- Net
- −423 Wh
The battery loses about 10 % of its usable charge a day; a full battery lasts about 9 days like this.
With no charging at all, the 4,096 Wh above a 20 % reserve lasts about 3 days at the larger daily use. In Crimp, switch loads on and off in the drawing to see the live current and runtime.
Parts list
22 parts. Each links to its Crimp page with the manufacturer's ratings and installation notes.
- Vehicle starter battery 12 VPlanning placeholder12 V · 80 Ah
- DC-DC charger 12/24 V 10 AOrion-Tr Smart 12/24-1010 A rated / planning output
- Roof solar panel 200 WRSP200D22.6 V · 8.85 A rated / planning output · 200 W · 27 V STC Voc
- Roof solar panel 200 WRSP200D22.6 V · 8.85 A rated / planning output · 200 W · 27 V STC Voc
- Roof solar panel 200 WRSP200D22.6 V · 8.85 A rated / planning output · 200 W · 27 V STC Voc
- Solar isolatorPlanning placeholder
- Solar charge controllerSmartSolar 150/3535 A rated / planning output
- House battery 200 Ah LiFePO4 (upper)RBT12200LFP-M12.8 V · 200 Ah
- House battery 200 Ah LiFePO4 (lower)RBT12200LFP-M12.8 V · 200 Ah
- Battery monitorSmartShunt 500A/50mV (IP21)
- Main battery switchPlanning placeholder
- Positive bus bar 24 VPlanning placeholder
- Negative bus bar 24 VPlanning placeholder
- Fuse block 24 V5025
- 24/12 V converter 15 AOrion-Tr 24/12-1515 A rated / planning output
- Fuse block 12 V5025
- Compressor fridgeCRX-655.5 A load allowance · 66 W
- Starlink MiniStarlink Mini12 V · 2.5 A load allowance · 30 W
- USB-C chargingPlanning placeholder5.5 A load allowance · 60 W
- Diesel heater 12 VAirtronic D44 A load allowance · 40 W
- LED lights 12 VPlanning placeholder2 A load allowance · 24 W
- Water pump 12 VUniversal6 A load allowance
Cable and fuse sizes
Sized by Crimp's ABYC E-11 based engine for these lengths. Lengths are one way; AWG is the approximate counterpart of the metric size.
| Connection | Length | Wire | Design current | Fuse | Drop |
|---|---|---|---|---|---|
| C1 · Vehicle starter battery 12 V + → DC-DC charger 12/24 V 10 A IN + | 2 m6.6 ft | 10 mm²AWG 8manufacturer size | 23.7 A | — | 0.69% |
| C2 · Vehicle starter battery 12 V − → DC-DC charger 12/24 V 10 A IN − | 2 m6.6 ft | 10 mm²AWG 8manufacturer size | 23.7 A | — | 0.69% |
| C3 · DC-DC charger 12/24 V 10 A OUT + → Positive bus bar 24 V + | 1 m3.3 ft | 6 mm²AWG 10manufacturer size | 10 A | 30 A | 0.11% |
| C4 · DC-DC charger 12/24 V 10 A OUT − → Negative bus bar 24 V 1 − | 1 m3.3 ft | 6 mm²AWG 10manufacturer size | 10 A | — | 0.11% |
| C5 · Roof solar panel 200 W − → Roof solar panel 200 W + | 1 m3.3 ft | 1.5 mm²AWG 16 | 8.8 A | — | 0.15% |
| C6 · Roof solar panel 200 W − → Roof solar panel 200 W + | 1 m3.3 ft | 1.5 mm²AWG 16 | 8.8 A | — | 0.15% |
| C7 · Roof solar panel 200 W + → Solar isolator IN + | 4 m13.1 ft | 1.5 mm²AWG 16 | 8.8 A | 15 A | 0.61% |
| C8 · Roof solar panel 200 W − → Solar isolator IN − | 4 m13.1 ft | 1.5 mm²AWG 16 | 8.8 A | — | 0.61% |
| C9 · Solar isolator OUT + → Solar charge controller PV + | 50 cm1.6 ft | 1.5 mm²AWG 16 | 8.8 A | 15 A | 0.08% |
| C10 · Solar isolator OUT − → Solar charge controller PV − | 50 cm1.6 ft | 1.5 mm²AWG 16 | 8.8 A | — | 0.08% |
| C11 · Solar charge controller BATT + → Positive bus bar 24 V 1 + | 1 m3.3 ft | 6 mm²AWG 10manufacturer size | 35 A | 40 A | 0.40% |
| C12 · Solar charge controller BATT − → Negative bus bar 24 V 2 − | 1 m3.3 ft | 4 mm²AWG 11 | 35 A | — | 0.60% |
| C13 · House battery 200 Ah LiFePO4 (upper) − → House battery 200 Ah LiFePO4 (lower) + | 30 cm1.0 ft | 16 mm²AWG 6 | 52.6 A | — | 0.07% |
| C14 · House battery 200 Ah LiFePO4 (upper) + → Main battery switch A | 40 cm1.3 ft | 16 mm²AWG 6 | 64.7 A | — | 0.11% |
| C15 · Main battery switch B → Positive bus bar 24 V 2 + | 30 cm1.0 ft | 16 mm²AWG 6 | 52.6 A | — | 0.07% |
| C16 · House battery 200 Ah LiFePO4 (lower) − → Battery monitor BATT − | 30 cm1.0 ft | 16 mm²AWG 6 | 67.6 A | — | 0.09% |
| C17 · Battery monitor LOAD − → Negative bus bar 24 V 5 − | 30 cm1.0 ft | 16 mm²AWG 6 | 67.6 A | — | 0.09% |
| C18 · Positive bus bar 24 V 3 + → Fuse block 24 V IN + | 50 cm1.6 ft | 1.5 mm²AWG 16 | 19.7 A | 25 A | 0.45% |
| C19 · Fuse block 24 V IN − → Negative bus bar 24 V 4 − | 50 cm1.6 ft | 1.5 mm²AWG 16 | 12.2 A | — | 0.28% |
| C20 · Fuse block 24 V 2 + → Compressor fridge + | 3 m9.8 ft | 1.5 mm²AWG 16manufacturer size | 5.5 A | 7.5 A | 0.75% |
| C21 · Compressor fridge − → Fuse block 24 V 1 − | 3 m9.8 ft | 1.5 mm²AWG 16 | 5.5 A | — | 0.75% |
| C22 · Fuse block 24 V 3 + → Starlink Mini + | 4 m13.1 ft | 1.5 mm²AWG 16manufacturer size | 1.2 A | 5 A | 0.21% |
| C23 · Starlink Mini − → Fuse block 24 V 2 − | 4 m13.1 ft | 1.5 mm²AWG 16 | 1.2 A | — | 0.21% |
| C24 · Fuse block 24 V 4 + → USB-C charging + | 3 m9.8 ft | 1.5 mm²AWG 16 | 5.5 A | 7.5 A | 0.75% |
| C25 · USB-C charging − → Fuse block 24 V 3 − | 3 m9.8 ft | 1.5 mm²AWG 16 | 5.5 A | — | 0.75% |
| C26 · Fuse block 24 V 1 + → 24/12 V converter 15 A IN + | 1 m3.3 ft | 1.5 mm²AWG 16 | 7.6 A | 10 A | 0.34% |
| C27 · 24/12 V converter 15 A IN − → Negative bus bar 24 V 3 − | 1.5 m4.9 ft | 2.5 mm²AWG 13 | 22.6 A | — | 0.92% |
| C28 · 24/12 V converter 15 A OUT + → Fuse block 12 V IN + | 50 cm1.6 ft | 2.5 mm²AWG 13 | 15 A | 20 A | 0.42% |
| C29 · Fuse block 12 V IN − → 24/12 V converter 15 A OUT − | 50 cm1.6 ft | 2.5 mm²AWG 13 | 15 A | — | 0.42% |
| C30 · Fuse block 12 V 1 + → Diesel heater 12 V + | 2 m6.6 ft | 1.5 mm²AWG 16manufacturer size | 4 A | 20 A | 0.75% |
| C31 · Diesel heater 12 V − → Fuse block 12 V 1 − | 2 m6.6 ft | 1.5 mm²AWG 16 | 4 A | — | 0.75% |
| C32 · Fuse block 12 V 2 + → LED lights 12 V + | 5 m16.4 ft | 1.5 mm²AWG 16 | 2 A | 3 A | 0.93% |
| C33 · LED lights 12 V − → Fuse block 12 V 2 − | 5 m16.4 ft | 1.5 mm²AWG 16 | 2 A | — | 0.93% |
| C34 · Fuse block 12 V 3 + → Water pump 12 V + | 2 m6.6 ft | 2.5 mm²AWG 13 | 6 A | 7.5 A | 0.67% |
| C35 · Water pump 12 V − → Fuse block 12 V 3 − | 2 m6.6 ft | 2.5 mm²AWG 13 | 6 A | — | 0.67% |
A dash means the cable has no fuse of its own: a negative, or a run protected by the fuse upstream of it. Fuses on a battery post are listed with the battery in the drawing.
How it is wired
01
Two batteries, one 24 V bank
A short jumper joins the upper battery's negative to the lower battery's positive. The bank positive is the upper battery's positive, which carries the fuse; the bank negative is the lower battery's negative, which goes through the shunt. Use two identical batteries, charged to the same voltage before you join them.
02
Series solar into a 150 V controller
Three panels in series add their voltages, about 81 V open-circuit before the cold correction, and keep one panel's current. That leaves room under the 150/35's 150 V limit and a thin string cable from the roof.
03
12 V vehicle, 24 V house
The vehicle stays 12 V. The Orion-Tr Smart 12/24-10 takes its 12 V input through a 60 A fuse at the vehicle battery and charges the house through a 30 A fuse on its 24 V side, the two rows of Victron's table.
04
A 12 V fuse block behind a converter
Loads that come in 24 V run from the 24 V fuse block. The heater, lights and pump only come in 12 V, so a 24/12 converter on its own fused slot feeds a second fuse block. Keep its 15 A continuous rating above the 12 V loads that run together.
Before you build
Crimp's checks on this drawing: 0 critical, 4 to review. They stay visible when you open it.
- Measure your own cable runs and re-check the sizes in Crimp after changing them.
- Check your panels' cold-weather Voc times three against the controller's 150 V limit, and the 145 V on its datasheet.
- Balance the two batteries to the same voltage before joining them in series, and check them separately now and then.
- Every 24 V load must accept 24 V; read the label before connecting anything that came from a 12 V van.
- warning: CRX-65: verify manufacturer wiring
- warning: Check monitor power: Battery monitor
- info: Check fuse suitability: House battery 200 Ah LiFePO4 (upper) (+1)
- info: Check fuse suitability: Vehicle starter battery 12 V
A planning example, not an installation certificate. Sizing follows Crimp's published method; check the manufacturer manuals below for your exact parts.
Questions about this system
Should a campervan be 12V or 24V?
12 V suits most vans: every van part comes in 12 V and the vehicle is already 12 V. 24 V pays off with a large inverter or long, heavy runs, because the same power takes half the current. This drawing is a 24 V van with small loads to show the wiring; with only a fridge, Starlink and USB-C on 24 V, a 12 V system would serve as well.
How do I wire two 12V lithium batteries in series for 24V?
Join the negative of one battery to the positive of the other with a short cable. The free positive is the bank positive and carries the main fuse; the free negative is the bank negative and goes through the shunt. Use identical batteries, charge each to the same voltage first, and check the manufacturer allows series use: Renogy allows up to four of these.
How do I charge a 24V house battery from a 12V vehicle?
With a step-up DC-DC charger such as Victron's Orion-Tr Smart 12/24. It needs a 60 A fuse on the 12 V vehicle side and a 30 A fuse on the 24 V house side, and at 2 m a 10 mm² input and 6 mm² output cable. It puts out 10 A at 24 V, about 260 Wh for each hour of driving in this drawing.
Can I run 12V appliances on a 24V system?
Through a 24/12 converter. This drawing uses a non-isolated Orion-Tr 24/12-15, which gives a fixed 12.5 V at up to 15 A continuous, and puts the heater, lights and pump on their own 12 V fuse block behind it. Never connect a 12 V appliance straight to 24 V.
How long does a 24V 200Ah lithium battery last?
Two 12.8 V 200 Ah batteries in series hold about 5,120 Wh, about 4,100 Wh above a 20 % reserve. This drawing uses about 950 Wh on a summer day and about 1,350 Wh on a winter day with the heater, so it runs about three days on a winter day's use with no charging.
Manufacturer sources
Reviewed 26 November 2026.
Start from this system instead of a blank page.
Open this diagram in Crimp