BCDC1225D Classic25
REDARC BCDC1225D wiring diagram
Keep an auxiliary battery charged from the vehicle and solar. Follow the BCDC1225D’s colour-coded leads, battery fuses and shared ground in one editable dual-battery example.
Free, no account needed.
- Auxiliary battery
- 12 V
- Charge output
- 25 A · 375 W
- Vehicle input
- 9–32 V
Checked against the manufacturer manual, Nov 2026.
Wiring diagram
Vehicle and solar charging for an auxiliary battery
Follow RED from the starter battery, YELLOW from solar and BROWN to the auxiliary battery. All returns meet at the single BLACK ground lead. Blue, orange and green remain unused in this example.

Classic25 manual INST330-3 EN specifies 40 A fuses at both batteries. This AGM Profile A example uses the manual’s short-run cable guidance. Check actual cable length, mounting temperature and battery settings. Manufacturer installation manual
Get wire sizes for my setupFree, no account needed.
Quick answers
Cable and fuse
10 mm² (8 AWG) with a 40 A fuse for a 80 cm one-way run (12 V system). Sizes for other lengths
Auxiliary-battery cable reference
Classic25, 25 A output. This example uses an AGM battery, a standard alternator and an unregulated solar panel.
80 cm one way
12 V system
- Wire
- 10 mm² · 8 AWG
- Example fuse
- 40 A
- Design current
- 25 A
- Voltage drop
- 0.6%
Cable size by run length
| One way | Wire | Fuse | Voltage drop |
|---|---|---|---|
| 80 cm (worked example above) | 10 mm² · 8 AWG | 40 A | 0.6% |
| 1 m | 10 mm² · 8 AWG | 40 A | 0.7% |
| 2 m | 10 mm² · 8 AWG | 40 A | 1.5% |
| 3 m | 10 mm² · 8 AWG | 40 A | 2.3% |
Same circuit and current, sized by Crimp's engine at each length. Longer runs, warmer spaces or engine rooms need the editor's full check.
Sized against ABYC E-11. The design current is the unit's rated output. The length is one way; voltage drop includes an equal-length return.
Already have a cable size? Check a simple copper run at your current and length with the DC voltage drop calculator in mm² or AWG.
Run-length and manufacturer assumptions
The editable example uses 10 ft (3 m) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.
Classic25 manual INST330-3 EN specifies 40 A fuses at both batteries. This AGM Profile A example uses the manual’s short-run cable guidance. Check actual cable length, mounting temperature and battery settings. Manufacturer installation manual
Supporting parts
- 11.6 m total of 10 mm² (8 AWG) marine cable
- Terminations for 10 mm² cable, matched to the equipment's screw terminals, leads or studs
- 40 A fuse and holder on the positive run
- Heat-shrink, strain relief and terminal boots sized to the cable
Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.
Installation notes
Before you install.
Open a question for model-specific guidance and sources.
Verified against the manufacturer's documentation (rev. INST330-3 EN), checked 2026-11-26. Manufacturer documentation →
Which REDARC BCDC1225D is this?
This is the seven-lead BCDC1225D Classic25: a 25 A charger for a 12 V auxiliary battery, with vehicle and unregulated solar inputs. It suits a dual-battery vehicle where driving and solar both replenish the auxiliary bank. The older six-lead version needs its own manual.
How is the REDARC BCDC1225D wired?
RED connects to vehicle positive, BROWN to auxiliary positive, YELLOW to solar positive and BLACK to the common negative return. The manual specifies 40 A fuses at both battery-positive connections. Its cable table governs conductor selection; the Technical reference describes the example’s output run.
BLUE selects the trigger arrangement, ORANGE selects the battery profile and GREEN is the optional LED output. The AGM Profile A example leaves these three leads insulated and disconnected.
What should I bear in mind with the REDARC BCDC1225D?
Match the exact revision, battery chemistry and alternator before choosing control wiring.
- Solar voltage: keep the unregulated panel within the manual’s 9–32 V input range, including cold open-circuit voltage. A panel’s nominal “12 V” label is insufficient. See the Classic25 manual.
- Heat and triggering: output derates above 55°C. Smart-alternator and lithium installations require the manual’s specific BLUE and ORANGE connections; do not copy this AGM example unchanged.
What do owners and installers say about the REDARC BCDC1225D?
Owners’ troubleshooting reports make voltage measurements at the battery and charger useful starting points. In one low-voltage thread, readings differed between the charger lead and auxiliary battery, and a reply suggested checking the ground. The thread does not establish a confirmed fix or a general charger fault.
What belongs around the REDARC BCDC1225D?
Start with the editable dual-battery example above, then add distribution and loads. Explore complete dual-battery systems, compare the BCDC1240D, and check longer cable routes with the wire-size calculator.
Technical reference
Specifications and terminal map.
Check the model, ratings and connection points against your own unit before choosing installation hardware.
Catalog specification
BCDC1225D Classic25, 25 A vehicle and solar charger for a 12 V auxiliary battery. Seven-lead INST330-3 revision with a common ground and separate trigger, profile and LED leads.
- Auxiliary battery
- 12 V
- Charge output
- 25 A · 375 W
- Vehicle input
- 9–32 V
- Unregulated solar input
- 9–32 V
- Manual battery fuses
- 40 A on each battery positive
Terminal map
RED: vehicle positive. BROWN: auxiliary positive. YELLOW: unregulated solar positive. BLACK: common ground. BLUE: trigger. ORANGE: profile selection. GREEN: optional LED output. Do not apply older six-lead profile wiring to this seven-lead revision.
RED · VEHICLE +
positive · input
YELLOW · SOLAR +
positive · input
BROWN · BATT +
positive · output
BLACK · GROUND
negative · bidi
BLUE · TRIGGER
signal · input
ORANGE · PROFILE
signal · input
GREEN · LED
signal · output
A dash means a current rating is not specified here.
Sources and sizing method
Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.
Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.
Read how the sizing worksNext step