Protect the cabin battery

Put a BatteryProtect in the lighting branch while leaving the solar charging path available to recover the battery.

Red = positive · dark = return · crossings are not junctions. Full screen

Follow the circuit

  1. 01

    Follow IN to OUT

    Battery power enters IN and leaves OUT for the lights. Keeping the charger upstream avoids reverse charging current through the BatteryProtect.

  2. 02

    Give GND its own lead

    The thin GND wire is a reference connection. It goes directly to battery negative and carries no other equipment return.

  3. 03

    Keep inverters separate

    This branch is for DC loads. Victron requires inverter control through the inverter's remote input, not through a BatteryProtect in its main DC feed.

The source and this example

Victron's BatteryProtect simple-system diagram shows a fused battery feed, one-way load output, dedicated GND lead and factory remote loop.

The cabin lighting branch uses that arrangement. Solar remains upstream. Crimp models the power conductors; the cutoff threshold, delay and retained remote loop are not simulated.

Before you build

  • Program the battery's shutdown and restart thresholds before connecting the load.
  • Select the GND lead's 300 mA protection and verify the main fuse against the installed cable.
  • Check the factory remote loop and actual device settings; the canvas does not test timed shutdown.

This is a planning example. Cable sizing uses Crimp’s ABYC-based method; the drawing does not certify an installation.

Cable sizes and connections · 12 conductors

Lengths are one way. Sizes and currents come from the same Crimp model as the drawing. Each drop value covers one drawn conductor; the full circuit includes its supply and return. AWG values are approximate counterparts to the metric areas.

Cable table units
Protect the cabin battery cable schedule
ConnectionLengthWireDesign currentFuseDrop
C1 · Victron 175W Mono +
→ Solar DP Isolator IN +
3 m2.5 mm²AWG 139 A—0.98%
C2 · Victron 175W Mono −
→ Solar DP Isolator IN −
3 m2.5 mm²AWG 139 A—0.98%
C3 · Solar DP Isolator OUT +
→ Victron MPPT 75/15 PV +
30 cm1.5 mm²AWG 169 A—0.16%
C4 · Solar DP Isolator OUT −
→ Victron MPPT 75/15 PV −
30 cm1.5 mm²AWG 169 A—0.16%
C5 · Victron MPPT 75/15 BATT +
→ Positive Bus Bar 1 +
1 m2.5 mm²AWG 1315 A20 A0.88%
C6 · Victron MPPT 75/15 BATT −
→ Negative Bus Bar 3 −
1 m2.5 mm²AWG 1315 A—0.88%
C7 · Victron AGM Deep Cycle 12V/110Ah +
→ Positive Bus Bar +
15 cm4 mm²AWG 1115 A—0.08%
C8 · Victron AGM Deep Cycle 12V/110Ah −
→ Negative Bus Bar −
60 cm2.5 mm²AWG 1315 A—0.53%
C9 · Cabin lighting · 2 A −
→ Negative Bus Bar 2 −
3 m1.5 mm²AWG 162 A—0.58%
C10 · Positive Bus Bar 2 +
→ BatteryProtect 100 IN
30 cm1.5 mm²AWG 162 A3 A0.06%
C11 · BatteryProtect 100 OUT
→ Cabin lighting · 2 A +
3 m1.5 mm²AWG 162 A—0.58%
C12 · BatteryProtect 100 GND
→ Victron AGM Deep Cycle 12V/110Ah −
40 cm1.5 mm²AWG 160 A0.3 A0.00%

A dash means no fuse is assigned to that conductor; upstream protection may apply. Recheck the exact device, holder and placement after edits.

Equipment · 8 components
  • Victron 175W Mono

    19.4 V · 9.03 A rated / planning output · 175 W · 23.7 V STC Voc

    175W rigid mono panel, 12V nominal (Vmp 19.4V, Voc 23.7V) — works with PWM or MPPT controllers. 1485×668×30mm, 11kg, MC4 connectors.

  • Solar DP Isolator

    Illustrative two-pole PV disconnect. Select an actual DC-rated device for the array's cold open-circuit voltage and short-circuit current.

  • Victron MPPT 75/15

    15 A rated / planning output

    75/15 battery circuit: 20 A fuse, within Victron's 20–25 A range. The controller's LOAD terminals are unused; the lighting branch is battery-fed.

  • Victron AGM Deep Cycle 12V/110Ah

    12 V · 110 Ah

    40 A terminal fuse is this example's cable-protection choice. Verify the selected fuse, holder and interrupt capacity against the actual battery. Ah does not establish fault current.

  • Positive Bus Bar

    Positive bus bar — common feed with multiple output studs.

  • Cabin lighting · 2 A

    2 A load allowance · 24 W

    Generic 2 A lighting allowance. Replace it with the actual lamps and hours used before relying on the energy budget.

  • Negative Bus Bar

    Negative bus bar — common return with multiple output studs.

  • BatteryProtect 100

    Factory remote loop retained. Crimp models the DC power path; the programmed cutoff voltage and 90-second delay are not simulated. GND is a dedicated 1.5 mm² lead with the manual's 300 mA fuse.

Crimp checks · 1 finding to review

These are the current engine findings for the saved example. They remain visible when you open it in Crimp.

  • warning: Check fuse suitability: AGM 110Ah

More off-grid cabin examples

View all five →