This is the van that cooks on electricity and works from anywhere: a 400 Ah LiFePO4 battery, 800 W of roof solar, a 50 A DC-DC charger, and a Victron MultiPlus-II 12/3000, which is both a 2400 W inverter and a 120 A charger with a 32 A transfer switch for hook-ups. The MultiPlus takes its own 400 A fuse and the heaviest cables in the van; the 12 V loads run from a fuse block as usual. With half an hour of induction cooking, a kettle and a laptop on the inverter, a sunny summer day puts back more than it uses. In winter, the hook-up charger does the heavy lifting.
The wiring diagram
19 components · 33 conductors · 12 V

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.
View full screenRed = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.
What it powers
Each load's draw comes from its catalog entry. The hours are this guide's assumptions; change them to yours.
| Load | Draw | Hours a day | Energy a day | Why |
|---|---|---|---|---|
| Compressor fridge | 66 W | 6 h | 396 Wh | A compressor fridge cycles; about a quarter of the day, more in hot weather. |
| LED lights | 24 W | 5 h | 120 Wh | Evenings. |
| Roof fan | 60 W | 4 hsummer only | 240 Wh | Warm evenings at full speed; lower speeds draw less. |
| Water pump | 72 W | 0.25 h | 18 Wh | About 15 minutes of washing and cooking. |
| Starlink Mini | 30 W | 10 h | 300 Wh | A working day plus the evening. |
| Diesel heater | 40 W | 10 hwinter only | 400 Wh | Evenings and overnight in cold weather; nothing in summer. |
| Induction hob (AC, via the inverter) | 1800 W | 30 min | 900 Wh | AC energy; the battery supplies it divided by 85 % inverter efficiency. |
| Electric kettle (AC, via the inverter) | 2000 W | 6 min | 200 Wh | AC energy; the battery supplies it divided by 85 % inverter efficiency. |
| Laptop (AC, via the inverter) | 65 W | 6 h | 390 Wh | AC energy; the battery supplies it divided by 85 % inverter efficiency. |
| Inverter loads, from the battery | 1,753 Wh | |||
| Total a day | 2,827 Wh summer 2,987 Wh winter |
Energy budget
What goes in against what comes out, per day. Solar assumes 5 peak sun hours in summer and 1.5 in winter at 75 % panel-to-battery efficiency; the alternator figure assumes 1 hour of driving.
A summer day
- Solar in
- +3,000 Wh
- Driving in (1 h)
- +640 Wh
- Used
- −2,827 Wh
- Net
- +813 Wh
The battery ends the day fuller than it started.
A winter day
- Solar in
- +900 Wh
- Driving in (1 h)
- +640 Wh
- Used
- −2,987 Wh
- Net
- −1,447 Wh
The battery loses about 35 % of its usable charge a day; a full battery lasts about 2 days like this.
With no charging at all, the 4,096 Wh above a 20 % reserve lasts about 1.4000000000000001 days at the larger daily use. In Crimp, switch loads on and off in the drawing to see the live current and runtime.
Parts list
19 parts. Each links to its Crimp page with the manufacturer's ratings and installation notes.
- Vehicle starter batteryPlanning placeholder12 V · 80 Ah
- DC-DC charger 50 ADCC50S50 A rated / planning output
- Roof solar panel 400 W 1RSP400DCT34 V · 11.76 A rated / planning output · 400 W · 39.42 V STC Voc
- Roof solar panel 400 W 2RSP400DCT34 V · 11.76 A rated / planning output · 400 W · 39.42 V STC Voc
- Solar isolatorPlanning placeholder
- Solar charge controllerSmartSolar 150/7070 A rated / planning output
- House battery 400 Ah LiFePO4RBT12400LFPL-SHBT12.8 V · 400 Ah
- Battery monitorSmartShunt 500A/50mV (IP21)
- Main battery switchPlanning placeholder
- Positive bus bar2104
- Negative bus bar2127
- Inverter/charger 3000 VAMultiPlus-II 12/3000/120-32 230V215 A load allowance · 120 A rated / planning output · 2400 W
- Fuse block5025
- Compressor fridgeCRX-655.5 A load allowance · 66 W
- LED lightsPlanning placeholder2 A load allowance · 24 W
- Roof fanMaxxfan Deluxe 7500K5 A load allowance
- Water pumpUniversal6 A load allowance
- Starlink MiniStarlink Mini12 V · 2.5 A load allowance · 30 W
- Diesel heaterAirtronic D44 A load allowance · 40 W
Cable and fuse sizes
Sized by Crimp's ABYC E-11 based engine for these lengths. Lengths are one way; AWG is the approximate counterpart of the metric size.
| Connection | Length | Wire | Design current | Fuse | Drop |
|---|---|---|---|---|---|
| C1 · Vehicle starter battery + → DC-DC charger 50 A ALT + | 3 m9.8 ft | 16 mm²AWG 6manufacturer size | 59.3 A | — | 1.62% |
| C2 · Vehicle starter battery − → Negative bus bar − 2 | 3 m9.8 ft | 16 mm²AWG 6manufacturer size | 59.3 A | — | 1.62% |
| C3 · DC-DC charger 50 A OUT + → Positive bus bar 1 | 1 m3.3 ft | 16 mm²AWG 6manufacturer size | 50 A | 65 A | 0.43% |
| C4 · DC-DC charger 50 A NEG − → Negative bus bar − 3 | 1 m3.3 ft | 16 mm²AWG 6manufacturer size | 9.3 A | — | 0.08% |
| C5 · Roof solar panel 400 W 1 + → Solar isolator IN + | 4 m13.1 ft | 2.5 mm²AWG 13 | 11.8 A | 15 A | 0.97% |
| C6 · Roof solar panel 400 W 2 + → Solar isolator IN + | 4 m13.1 ft | 2.5 mm²AWG 13 | 11.8 A | 15 A | 0.97% |
| C7 · Roof solar panel 400 W 1 − → Solar isolator IN − | 4 m13.1 ft | 2.5 mm²AWG 13 | 11.8 A | — | 0.97% |
| C8 · Roof solar panel 400 W 2 − → Solar isolator IN − | 4 m13.1 ft | 2.5 mm²AWG 13 | 11.8 A | — | 0.97% |
| C9 · Solar isolator OUT + → Solar charge controller PV + | 50 cm1.6 ft | 2.5 mm²AWG 13 | 23.5 A | 30 A | 0.24% |
| C10 · Solar isolator OUT − → Solar charge controller PV − | 50 cm1.6 ft | 2.5 mm²AWG 13 | 23.5 A | — | 0.24% |
| C11 · Solar charge controller BATT + → Positive bus bar 2 | 1 m3.3 ft | 16 mm²AWG 6manufacturer size | 70 A | 80 A | 0.60% |
| C12 · Solar charge controller BATT − → Negative bus bar − 4 | 1 m3.3 ft | 16 mm²AWG 6 | 70 A | — | 0.60% |
| C13 · House battery 400 Ah LiFePO4 + → Main battery switch A | 30 cm1.0 ft | 120 mm²AWG 4/0 | 240 A | — | 0.08% |
| C14 · Main battery switch B → Positive bus bar 4 | 30 cm1.0 ft | 120 mm²AWG 4/0 | 240 A | — | 0.08% |
| C15 · House battery 400 Ah LiFePO4 − → Battery monitor BATT − | 30 cm1.0 ft | 70 mm²AWG 2/0 | 240 A | — | 0.14% |
| C16 · Battery monitor LOAD − → Negative bus bar 7 − | 30 cm1.0 ft | 70 mm²AWG 2/0 | 240 A | — | 0.14% |
| C17 · Positive bus bar 3 → Inverter/charger 3000 VA DC + | 1.5 m4.9 ft | 120 mm²AWG 4/0manufacturer size | 215 A | 400 A | 0.37% |
| C18 · Inverter/charger 3000 VA DC − → Negative bus bar 4 − | 1.5 m4.9 ft | 70 mm²AWG 2/0 | 215 A | — | 0.63% |
| C19 · Inverter/charger 3000 VA CHASSIS / PE − → Negative bus bar 5 − | 1.5 m4.9 ft | 1.5 mm²AWG 16 | 0 A | — | 0.00% |
| C20 · Positive bus bar 4 → Fuse block IN + | 50 cm1.6 ft | 6 mm²AWG 10 | 24.8 A | 35 A | 0.28% |
| C21 · Fuse block IN − → Negative bus bar 6 − | 50 cm1.6 ft | 6 mm²AWG 10 | 24.8 A | — | 0.28% |
| C22 · Fuse block 1 + → Compressor fridge + | 3 m9.8 ft | 6 mm²AWG 10manufacturer size | 5.5 A | 15 A | 0.38% |
| C23 · Compressor fridge − → Fuse block 1 − | 3 m9.8 ft | 6 mm²AWG 10 | 5.5 A | — | 0.38% |
| C24 · Fuse block 2 + → LED lights + | 5 m16.4 ft | 1.5 mm²AWG 16 | 2 A | 3 A | 0.91% |
| C25 · LED lights − → Fuse block 2 − | 5 m16.4 ft | 1.5 mm²AWG 16 | 2 A | — | 0.91% |
| C26 · Fuse block 3 + → Roof fan + | 3 m9.8 ft | 2.5 mm²AWG 13 | 5 A | 7.5 A | 0.82% |
| C27 · Roof fan − → Fuse block 3 − | 3 m9.8 ft | 2.5 mm²AWG 13 | 5 A | — | 0.82% |
| C28 · Fuse block 4 + → Water pump + | 2 m6.6 ft | 2.5 mm²AWG 13 | 6 A | 7.5 A | 0.66% |
| C29 · Water pump − → Fuse block 4 − | 2 m6.6 ft | 2.5 mm²AWG 13 | 6 A | — | 0.66% |
| C30 · Fuse block 5 + → Starlink Mini + | 4 m13.1 ft | 1.5 mm²AWG 16 | 2.3 A | 3 A | 0.85% |
| C31 · Starlink Mini − → Fuse block 5 − | 4 m13.1 ft | 1.5 mm²AWG 16 | 2.3 A | — | 0.85% |
| C32 · Fuse block 6 + → Diesel heater + | 2 m6.6 ft | 1.5 mm²AWG 16manufacturer size | 4 A | 20 A | 0.73% |
| C33 · Diesel heater − → Fuse block 6 − | 2 m6.6 ft | 1.5 mm²AWG 16 | 4 A | — | 0.73% |
A dash means the cable has no fuse of its own: a negative, or a run protected by the fuse upstream of it. Fuses on a battery post are listed with the battery in the drawing.
How it is wired
01
The MultiPlus gets its own branch
At full inverter output the MultiPlus draws over 200 A from a 12 V battery, with peaks well above that. It connects to the bus bars through its own 400 A class-T fuse and the heaviest cables in the van, kept short. Victron asks for two 50 mm² cables per polarity up to 5 m.
02
Four chargers, one bank
The solar controller, the DC-DC charger and the MultiPlus's charger all land on the same bus bars, so every source charges the battery and every load can use any of them. Set them to the same lithium charge voltage so none stops early.
03
The AC side is its own design
Only the DC side is drawn. The hook-up inlet, the MultiPlus's AC input and outputs, protective earth and RCDs follow Victron's manual and local wiring rules, and are best done by someone qualified.
04
Mind the battery's current
The REGO battery allows 350 A continuous. The MultiPlus at full output plus the 12 V loads stays under it, but a kettle and the hob at the same time exceed the inverter's 2400 W, so cook on one at a time. Size the MultiPlus's chassis earth lead as its manual asks: it carries no current in normal use, so Crimp cannot size it from a load and flags it for checking.
Before you build
Crimp's checks on this drawing: 0 critical, 7 to review. They stay visible when you open it.
- Measure the MultiPlus cable run and use the two-cable-per-polarity arrangement Victron specifies; Crimp sizes one conductor.
- Use a fuse at the battery with an interrupt rating suited to a 400 Ah lithium bank, such as class T.
- Check the two panels' cold-weather Voc and combined short-circuit current against the controller's 150 V and 50 A limits.
- Have the AC installation, earth bonding and RCDs done to local rules; they are not drawn here.
- warning: Sizing needs verification
- warning: Inverter/charger 3000 VA: verify manufacturer wiring
- warning: Check monitor power: Battery monitor
- info: Check inverter disconnection
- info: Check fuse suitability: House battery 400 Ah LiFePO4
- info: Check fuse suitability: Vehicle starter battery
- info: Verify the charge planning threshold
A planning example, not an installation certificate. Sizing follows Crimp's published method; check the manufacturer manuals below for your exact parts.
Questions about this system
What size fuse does a MultiPlus-II 12/3000 need?
Victron's installation manual gives a 400 A DC fuse for the 12/3000, with two 50 mm² cables per polarity for runs up to 5 m and two 70 mm² from 5 to 10 m. This drawing uses a 400 A class-T fuse, which also has the interrupt rating a large lithium bank calls for.
Can a 400Ah lithium battery run a 3000VA inverter?
Yes, for current: the MultiPlus-II 12/3000 delivers 2400 W continuous, a little over 200 A from 12 V, and the REGO 400 Ah allows 350 A continuous. Energy is the limit. Half an hour of an 1800 W hob takes about 1,060 Wh from the battery once inverter losses are counted, about a quarter of the 4,100 Wh it holds above its reserve.
Is 800W of solar enough for electric cooking in a van?
In summer, yes. This drawing uses about 2,830 Wh on a summer day including the hob, a kettle and a laptop, and the panels put back about 3,000 Wh in five sun hours. In winter they make about 900 Wh and an hour's drive about 640 Wh, against about 2,990 Wh of use, so the hook-up charger makes up the difference.
Inverter/charger or a separate inverter and charger?
An inverter/charger like the MultiPlus does both through one set of battery cables, and switches the van's AC outlets between hook-up and inverter automatically. Separate units are cheaper to replace one at a time and simpler to wire, as in the 200Ah inverter diagram. The MultiPlus makes most sense when you use hook-ups often and want one AC circuit for both.
How fast does a MultiPlus charge a 400Ah battery on hook-up?
Its charger is rated 120 A, about 1,500 W into a 12 V battery. From the 20 % reserve to full, a 400 Ah battery needs about 4,100 Wh, so roughly three hours if the van's loads are light. The 32 A transfer switch passes hook-up power to the AC outlets at the same time.