Black Week: 30% off Lifetime and Pro. Ends Sunday.

Campervan wiring diagram

400Ah lithium van wiring diagram with 800W solar & MultiPlus 3000

This is the van that cooks on electricity and works from anywhere: a 400 Ah LiFePO4 battery, 800 W of roof solar, a 50 A DC-DC charger, and a Victron MultiPlus-II 12/3000, which is both a 2400 W inverter and a 120 A charger with a 32 A transfer switch for hook-ups. The MultiPlus takes its own 400 A fuse and the heaviest cables in the van; the 12 V loads run from a fuse block as usual. With half an hour of induction cooking, a kettle and a laptop on the inverter, a sunny summer day puts back more than it uses. In winter, the hook-up charger does the heavy lifting.

The wiring diagram

19 components · 33 conductors · 12 V

Open this diagram in Crimp
400Ah lithium van wiring diagram with 800W solar & MultiPlus 3000: Vehicle starter battery, DC-DC charger 50 A, Roof solar panel 400 W 1, Roof solar panel 400 W 2, Solar isolator, Solar charge controller and 13 more parts, with the wire size and fuse marked on each cable.

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.

View full screen

Red = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.

What it powers

Each load's draw comes from its catalog entry. The hours are this guide's assumptions; change them to yours.

Loads and daily energy use
LoadDrawHours a dayEnergy a dayWhy
Compressor fridge66 W6 h396 WhA compressor fridge cycles; about a quarter of the day, more in hot weather.
LED lights24 W5 h120 WhEvenings.
Roof fan60 W4 hsummer only240 WhWarm evenings at full speed; lower speeds draw less.
Water pump72 W0.25 h18 WhAbout 15 minutes of washing and cooking.
Starlink Mini30 W10 h300 WhA working day plus the evening.
Diesel heater40 W10 hwinter only400 WhEvenings and overnight in cold weather; nothing in summer.
Induction hob (AC, via the inverter)1800 W30 min900 WhAC energy; the battery supplies it divided by 85 % inverter efficiency.
Electric kettle (AC, via the inverter)2000 W6 min200 WhAC energy; the battery supplies it divided by 85 % inverter efficiency.
Laptop (AC, via the inverter)65 W6 h390 WhAC energy; the battery supplies it divided by 85 % inverter efficiency.
Inverter loads, from the battery1,753 Wh
Total a day2,827 Wh summer
2,987 Wh winter

Energy budget

What goes in against what comes out, per day. Solar assumes 5 peak sun hours in summer and 1.5 in winter at 75 % panel-to-battery efficiency; the alternator figure assumes 1 hour of driving.

A summer day

Solar in
+3,000 Wh
Driving in (1 h)
+640 Wh
Used
−2,827 Wh
Net
+813 Wh

The battery ends the day fuller than it started.

A winter day

Solar in
+900 Wh
Driving in (1 h)
+640 Wh
Used
−2,987 Wh
Net
−1,447 Wh

The battery loses about 35 % of its usable charge a day; a full battery lasts about 2 days like this.

With no charging at all, the 4,096 Wh above a 20 % reserve lasts about 1.4000000000000001 days at the larger daily use. In Crimp, switch loads on and off in the drawing to see the live current and runtime.

Parts list

19 parts. Each links to its Crimp page with the manufacturer's ratings and installation notes.

Cable and fuse sizes

Sized by Crimp's ABYC E-11 based engine for these lengths. Lengths are one way; AWG is the approximate counterpart of the metric size.

Cable table units
Cable schedule
ConnectionLengthWireDesign currentFuseDrop
C1 · Vehicle starter battery +
→ DC-DC charger 50 A ALT +
3 m9.8 ft16 mm²AWG 6manufacturer size59.3 A—1.62%
C2 · Vehicle starter battery −
→ Negative bus bar − 2
3 m9.8 ft16 mm²AWG 6manufacturer size59.3 A—1.62%
C3 · DC-DC charger 50 A OUT +
→ Positive bus bar 1
1 m3.3 ft16 mm²AWG 6manufacturer size50 A65 A0.43%
C4 · DC-DC charger 50 A NEG −
→ Negative bus bar − 3
1 m3.3 ft16 mm²AWG 6manufacturer size9.3 A—0.08%
C5 · Roof solar panel 400 W 1 +
→ Solar isolator IN +
4 m13.1 ft2.5 mm²AWG 1311.8 A15 A0.97%
C6 · Roof solar panel 400 W 2 +
→ Solar isolator IN +
4 m13.1 ft2.5 mm²AWG 1311.8 A15 A0.97%
C7 · Roof solar panel 400 W 1 −
→ Solar isolator IN −
4 m13.1 ft2.5 mm²AWG 1311.8 A—0.97%
C8 · Roof solar panel 400 W 2 −
→ Solar isolator IN −
4 m13.1 ft2.5 mm²AWG 1311.8 A—0.97%
C9 · Solar isolator OUT +
→ Solar charge controller PV +
50 cm1.6 ft2.5 mm²AWG 1323.5 A30 A0.24%
C10 · Solar isolator OUT −
→ Solar charge controller PV −
50 cm1.6 ft2.5 mm²AWG 1323.5 A—0.24%
C11 · Solar charge controller BATT +
→ Positive bus bar 2
1 m3.3 ft16 mm²AWG 6manufacturer size70 A80 A0.60%
C12 · Solar charge controller BATT −
→ Negative bus bar − 4
1 m3.3 ft16 mm²AWG 670 A—0.60%
C13 · House battery 400 Ah LiFePO4 +
→ Main battery switch A
30 cm1.0 ft120 mm²AWG 4/0240 A—0.08%
C14 · Main battery switch B
→ Positive bus bar 4
30 cm1.0 ft120 mm²AWG 4/0240 A—0.08%
C15 · House battery 400 Ah LiFePO4 −
→ Battery monitor BATT −
30 cm1.0 ft70 mm²AWG 2/0240 A—0.14%
C16 · Battery monitor LOAD −
→ Negative bus bar 7 −
30 cm1.0 ft70 mm²AWG 2/0240 A—0.14%
C17 · Positive bus bar 3
→ Inverter/charger 3000 VA DC +
1.5 m4.9 ft120 mm²AWG 4/0manufacturer size215 A400 A0.37%
C18 · Inverter/charger 3000 VA DC −
→ Negative bus bar 4 −
1.5 m4.9 ft70 mm²AWG 2/0215 A—0.63%
C19 · Inverter/charger 3000 VA CHASSIS / PE −
→ Negative bus bar 5 −
1.5 m4.9 ft1.5 mm²AWG 160 A—0.00%
C20 · Positive bus bar 4
→ Fuse block IN +
50 cm1.6 ft6 mm²AWG 1024.8 A35 A0.28%
C21 · Fuse block IN −
→ Negative bus bar 6 −
50 cm1.6 ft6 mm²AWG 1024.8 A—0.28%
C22 · Fuse block 1 +
→ Compressor fridge +
3 m9.8 ft6 mm²AWG 10manufacturer size5.5 A15 A0.38%
C23 · Compressor fridge −
→ Fuse block 1 −
3 m9.8 ft6 mm²AWG 105.5 A—0.38%
C24 · Fuse block 2 +
→ LED lights +
5 m16.4 ft1.5 mm²AWG 162 A3 A0.91%
C25 · LED lights −
→ Fuse block 2 −
5 m16.4 ft1.5 mm²AWG 162 A—0.91%
C26 · Fuse block 3 +
→ Roof fan +
3 m9.8 ft2.5 mm²AWG 135 A7.5 A0.82%
C27 · Roof fan −
→ Fuse block 3 −
3 m9.8 ft2.5 mm²AWG 135 A—0.82%
C28 · Fuse block 4 +
→ Water pump +
2 m6.6 ft2.5 mm²AWG 136 A7.5 A0.66%
C29 · Water pump −
→ Fuse block 4 −
2 m6.6 ft2.5 mm²AWG 136 A—0.66%
C30 · Fuse block 5 +
→ Starlink Mini +
4 m13.1 ft1.5 mm²AWG 162.3 A3 A0.85%
C31 · Starlink Mini −
→ Fuse block 5 −
4 m13.1 ft1.5 mm²AWG 162.3 A—0.85%
C32 · Fuse block 6 +
→ Diesel heater +
2 m6.6 ft1.5 mm²AWG 16manufacturer size4 A20 A0.73%
C33 · Diesel heater −
→ Fuse block 6 −
2 m6.6 ft1.5 mm²AWG 164 A—0.73%

A dash means the cable has no fuse of its own: a negative, or a run protected by the fuse upstream of it. Fuses on a battery post are listed with the battery in the drawing.

How it is wired

  1. 01

    The MultiPlus gets its own branch

    At full inverter output the MultiPlus draws over 200 A from a 12 V battery, with peaks well above that. It connects to the bus bars through its own 400 A class-T fuse and the heaviest cables in the van, kept short. Victron asks for two 50 mm² cables per polarity up to 5 m.

  2. 02

    Four chargers, one bank

    The solar controller, the DC-DC charger and the MultiPlus's charger all land on the same bus bars, so every source charges the battery and every load can use any of them. Set them to the same lithium charge voltage so none stops early.

  3. 03

    The AC side is its own design

    Only the DC side is drawn. The hook-up inlet, the MultiPlus's AC input and outputs, protective earth and RCDs follow Victron's manual and local wiring rules, and are best done by someone qualified.

  4. 04

    Mind the battery's current

    The REGO battery allows 350 A continuous. The MultiPlus at full output plus the 12 V loads stays under it, but a kettle and the hob at the same time exceed the inverter's 2400 W, so cook on one at a time. Size the MultiPlus's chassis earth lead as its manual asks: it carries no current in normal use, so Crimp cannot size it from a load and flags it for checking.

Before you build

Crimp's checks on this drawing: 0 critical, 7 to review. They stay visible when you open it.

  • Measure the MultiPlus cable run and use the two-cable-per-polarity arrangement Victron specifies; Crimp sizes one conductor.
  • Use a fuse at the battery with an interrupt rating suited to a 400 Ah lithium bank, such as class T.
  • Check the two panels' cold-weather Voc and combined short-circuit current against the controller's 150 V and 50 A limits.
  • Have the AC installation, earth bonding and RCDs done to local rules; they are not drawn here.
  • warning: Sizing needs verification
  • warning: Inverter/charger 3000 VA: verify manufacturer wiring
  • warning: Check monitor power: Battery monitor
  • info: Check inverter disconnection
  • info: Check fuse suitability: House battery 400 Ah LiFePO4
  • info: Check fuse suitability: Vehicle starter battery
  • info: Verify the charge planning threshold

A planning example, not an installation certificate. Sizing follows Crimp's published method; check the manufacturer manuals below for your exact parts.

Questions about this system

What size fuse does a MultiPlus-II 12/3000 need?

Victron's installation manual gives a 400 A DC fuse for the 12/3000, with two 50 mm² cables per polarity for runs up to 5 m and two 70 mm² from 5 to 10 m. This drawing uses a 400 A class-T fuse, which also has the interrupt rating a large lithium bank calls for.

Can a 400Ah lithium battery run a 3000VA inverter?

Yes, for current: the MultiPlus-II 12/3000 delivers 2400 W continuous, a little over 200 A from 12 V, and the REGO 400 Ah allows 350 A continuous. Energy is the limit. Half an hour of an 1800 W hob takes about 1,060 Wh from the battery once inverter losses are counted, about a quarter of the 4,100 Wh it holds above its reserve.

Is 800W of solar enough for electric cooking in a van?

In summer, yes. This drawing uses about 2,830 Wh on a summer day including the hob, a kettle and a laptop, and the panels put back about 3,000 Wh in five sun hours. In winter they make about 900 Wh and an hour's drive about 640 Wh, against about 2,990 Wh of use, so the hook-up charger makes up the difference.

Inverter/charger or a separate inverter and charger?

An inverter/charger like the MultiPlus does both through one set of battery cables, and switches the van's AC outlets between hook-up and inverter automatically. Separate units are cheaper to replace one at a time and simpler to wire, as in the 200Ah inverter diagram. The MultiPlus makes most sense when you use hook-ups often and want one AC circuit for both.

How fast does a MultiPlus charge a 400Ah battery on hook-up?

Its charger is rated 120 A, about 1,500 W into a 12 V battery. From the 20 % reserve to full, a 400 Ah battery needs about 4,100 Wh, so roughly three hours if the van's loads are light. The 32 A transfer switch passes hook-up power to the AC outlets at the same time.

Manufacturer sources

Reviewed 26 November 2026.

Start from this system instead of a blank page.

Open this diagram in Crimp
Keep goingMultiPlus-II 12/3000 230 VThe inverter/charger's DC wiring on its own.Keep going200Ah campervan with 400W solar and a 2000W inverterA smaller system with a separate inverter.Keep goingLiFePO4 fuse sizeCheck the battery fuse and its interrupt rating.Keep goingWire size calculatorSize the inverter cable for your own run length.