Solar wiring diagram
Solar panel wiring diagram: series vs parallel, controller and battery
Solar panels never connect straight to a battery. They feed a charge controller, and the controller charges the battery. Wire it in this order: the battery to the controller's battery terminals through a fuse close to the battery, then the panels to the controller's PV terminals through a double-pole isolator. Two panels can go in series, which adds their voltages and keeps one panel's current, or in parallel, which keeps one panel's voltage and adds their currents. Either way, the cold-weather open-circuit voltage must stay under the controller's limit, and the current under its PV input rating.
Two panels in parallel
Positives joined to positives, negatives to negatives. One panel's voltage, twice the current: the cable from the roof carries 10.8 A.
6 components · 9 conductors

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.
View full screenRed = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.
Two panels in series
Panel 1's negative to panel 2's positive. Twice the voltage, one panel's current: the cable from the roof carries 5.4 A and can be thinner.
6 components · 8 conductors

Live Crimp simulation. Try equipment states and battery charge. Connections and cable sizes are listed below.
View full screenRed = positive · dark = return. Crossings are not junctions. Read the assumptions before adapting a circuit.
Series or parallel: what changes
Both drawings use two Renogy 100 W panels (22.3 V open-circuit, 18.6 V and 5.38 A at maximum power) on a Victron SmartSolar MPPT 100/20.
| Two in series | Two in parallel | |
|---|---|---|
| Open-circuit voltage | 44.6 V; about 53.5 V on a −25 °C morning | 22.3 V; about 26.8 V when cold |
| Current at full sun | 5.4 A | 10.8 A |
| Cable from the roof | Thinner: half the current | Thicker for the same voltage drop |
| Shade on one panel | Pulls down the whole string | Only that panel loses output |
| Controller limits (100/20) | Under 100 V open-circuit | Under 20 A short-circuit |
The cold factor is 1.20, from NEC Table 690.7(A) for crystalline panels at −25 °C, Crimp's default. Set your site's lowest temperature in the editor, and a panel's datasheet temperature coefficient gives a closer figure.
Step by step
01
Mount the controller near the battery
Keep the battery cable short. The controller's battery current here is up to 20 A, the PV current at most 10.8 A, so the long run belongs on the PV side.
02
Fuse the battery cable at the battery
Fit the fuse in the positive cable within a short distance of the battery post. Victron specifies 25 A minimum and 30 A maximum for the MPPT 100/20; the drawing uses 25 A.
03
Connect the battery first
Connect the controller's battery terminals before the panels, so the controller can detect the system voltage. Set the charge profile for your battery chemistry.
04
Wire the panels in series or parallel
For series, join panel 1's negative to panel 2's positive and take the free positive and negative to the isolator. For parallel, join positives together and negatives together, on a real roof with an MC4 branch pair, then take one pair down.
05
Run the PV cable through an isolator
A double-pole DC isolator between the roof and the controller lets you make the PV side dead before you touch it. Keep it switched off until everything is connected.
06
Switch on and check
Close the isolator and check the controller reports the PV voltage you expect: about 37 V at maximum power for two panels in series, about 18.6 V in parallel.
Cable and fuse sizes
Sized by Crimp's ABYC E-11 based engine for the lengths shown. Lengths are one way; AWG is the approximate counterpart of the metric size.
Two panels in parallel
| Connection | Length | Wire | Design current | Fuse | Drop |
|---|---|---|---|---|---|
| C1 · Solar panel 100 W + → Solar isolator IN + | 5 m16.4 ft | 2.5 mm²AWG 13 | 5.4 A | — | 1.01% |
| C2 · Solar panel 100 W − → Solar isolator IN − | 5 m16.4 ft | 2.5 mm²AWG 13 | 5.4 A | — | 1.01% |
| C3 · Solar panel 100 W + → Solar isolator IN + | 5 m16.4 ft | 2.5 mm²AWG 13 | 5.4 A | — | 1.01% |
| C4 · Solar panel 100 W − → Solar isolator IN − | 5 m16.4 ft | 2.5 mm²AWG 13 | 5.4 A | — | 1.01% |
| C5 · Solar isolator OUT + → Solar charge controller PV + | 50 cm1.6 ft | 1.5 mm²AWG 16 | 10.8 A | — | 0.34% |
| C6 · Solar isolator OUT − → Solar charge controller PV − | 50 cm1.6 ft | 1.5 mm²AWG 16 | 10.8 A | — | 0.34% |
| C7 · Battery 100 Ah LiFePO4 + → Battery fuse 25 A IN + | 10 cm0.3 ft | 1.5 mm²AWG 16 | 20 A | — | 0.18% |
| C8 · Battery fuse 25 A OUT + → Solar charge controller BATT + | 1 m3.3 ft | 2.5 mm²AWG 13set size | 20 A | 25 A | 1.09% |
| C9 · Solar charge controller BATT − → Battery 100 Ah LiFePO4 − | 1 m3.3 ft | 2.5 mm²AWG 13 | 20 A | — | 1.09% |
Two panels in series
| Connection | Length | Wire | Design current | Fuse | Drop |
|---|---|---|---|---|---|
| C1 · Solar panel 100 W − → Solar panel 100 W + | 1 m3.3 ft | 1.5 mm²AWG 16 | 5.4 A | — | 0.17% |
| C2 · Solar panel 100 W + → Solar isolator IN + | 5 m16.4 ft | 1.5 mm²AWG 16 | 5.4 A | — | 0.84% |
| C3 · Solar panel 100 W − → Solar isolator IN − | 5 m16.4 ft | 1.5 mm²AWG 16 | 5.4 A | — | 0.84% |
| C4 · Solar isolator OUT + → Solar charge controller PV + | 50 cm1.6 ft | 1.5 mm²AWG 16 | 5.4 A | — | 0.08% |
| C5 · Solar isolator OUT − → Solar charge controller PV − | 50 cm1.6 ft | 1.5 mm²AWG 16 | 5.4 A | — | 0.08% |
| C6 · Battery 100 Ah LiFePO4 + → Battery fuse 25 A IN + | 10 cm0.3 ft | 1.5 mm²AWG 16 | 20 A | — | 0.18% |
| C7 · Battery fuse 25 A OUT + → Solar charge controller BATT + | 1 m3.3 ft | 2.5 mm²AWG 13set size | 20 A | 25 A | 1.09% |
| C8 · Solar charge controller BATT − → Battery 100 Ah LiFePO4 − | 1 m3.3 ft | 2.5 mm²AWG 13 | 20 A | — | 1.09% |
A dash means the cable has no fuse of its own: a negative, a cable past a switch, or a run protected by the fuse upstream of it. Fuses on a battery post or in an inline holder are drawn on the diagram.
Common mistakes
Crimp's checks on these drawings: 0 critical, 2 to review. They stay visible when you open it.
- Connecting a panel straight to the battery. Without a controller it overcharges the battery in sun and can drain it at night.
- Connecting the panels before the battery. Most controllers need battery voltage first to set themselves up.
- Checking only the label voltage. A cold, bright morning raises open-circuit voltage by about a fifth; that is the number to keep under the controller's limit.
- Paralleling three or more strings without fuses. With two, a faulted string can only be fed by one other; with more, the others' combined current can exceed the panel's maximum series fuse rating (15 A for this panel).
- Putting the battery fuse at the controller end. It protects the cable from the battery, so it belongs at the battery.
- warning: Check fuse suitability: Battery 100 Ah LiFePO4 (Two panels in parallel)
- warning: Check fuse suitability: Battery 100 Ah LiFePO4 (Two panels in series)
A planning example, not an installation certificate. Sizing follows Crimp's published method; check the manufacturer documents below for your exact parts.
Questions
Should solar panels be wired in series or parallel?
Series if the run from the roof is long or the panels are rarely shaded: the current is lower, so the cable can be thinner, and an MPPT controller converts the higher voltage efficiently. Parallel if shade often falls on one panel, or the series voltage would exceed the controller's limit. Two 100 W panels in series reach about 53.5 V on a cold morning, well inside a 100 V controller.
Do solar panels make more power in series or parallel?
The same in full sun: two 100 W panels are 200 W either way. Series trades current for voltage, so less power is lost in the cable from the roof; parallel keeps working better when one panel is shaded. With a PWM controller, which pulls the panels down to battery voltage, the extra voltage of a series string is wasted, so series wiring suits an MPPT controller like the one in the drawings.
Can I wire four solar panels in series and parallel?
Yes: two strings of two in series, joined in parallel. With these panels that gives the series voltage, about 53.5 V on a cold morning, and twice the current, 10.8 A, inside a 100 V controller's input limits. A 100/20 can only charge at 20 A, though, so for 400 W choose a larger controller such as a 100/30 or 100/50. With two strings, no string fuses are needed; from three strings up, fuse each string.
Can I connect a solar panel directly to a battery?
No. Victron states solar panels are not allowed to be directly connected to a battery. The charge controller limits the charge voltage to what the battery accepts and stops current flowing back into the panel at night.
What size fuse goes between the charge controller and the battery?
Use the controller maker's figure. For the Victron MPPT 100/20 it is 25 A minimum and 30 A maximum, fitted in the positive cable close to the battery. The drawing uses 25 A.
Do I need a fuse between the solar panels and the controller?
Not with one or two strings like these: a fault in one string can only be fed by the other, below the panel's 15 A maximum series fuse rating. With three or more strings in parallel, fuse each string, or use a combiner with string fuses. Local rules may ask for a breaker or isolator on the PV side regardless.
How many panels can I put in series?
As many as keep the cold open-circuit voltage under the controller's maximum. On a 100 V controller, 22.3 V panels allow three: 3 × 22.3 × 1.2 is about 80 V, while four would reach about 107 V.
What size wire do I need for solar panels?
It depends on current and length. In these drawings, with 5 m from the roof, the parallel pair needs 2.5 mm² per panel lead while the series string manages on 1.5 mm². Open the drawing and enter your own lengths; Crimp resizes every cable.
Sources
Reviewed 26 November 2026.
Draw your own circuit, with every wire and fuse sized.
Start from this diagram