Black Week: 30% off Lifetime and Pro. Ends Sunday.

Charger

BLUETTI Charger 1 wiring diagram

Recharge a portable power station while you drive. See how Charger 1 connects a protected vehicle supply to the station’s solar input, with an AC180 as the worked example.

Free, no account needed.

Vehicle systems
12 / 24 V
Output ceiling
560 W · 10 A
Output from 12 V vehicle
15–56 V adjustable

Checked against the manufacturer manual, Nov 2026.

Connection overview

Charge an AC180 from a vehicle supply

The supplied input protection feeds Charger 1. Its MC4 output joins the AC180’s MC4-to-DC7909 solar cable. The station’s 12 V output socket is not a charging input.

BLUETTI Charger 1 connection diagram: 12 V starter battery, 60 A input breaker, Charger 1 and AC180 · DC7909 input.
BLUETTI Charger 1 connection overview with 4 components: 12 V starter battery, 60 A input breaker, Charger 1, AC180 · DC7909 input. 5 cable connections. Crossings are not junctions. Vehicle-to-AC180 charging connections. Retain the specified input protection and station cable; set output voltage for the AC180. Power sharing, charging rates and reverse modes are not simulated.

Retain the supplied 60 A breaker and 6 AWG input harness. Use the station’s solar charging cable and configure a compatible output voltage before connection. IP20: mount dry with ventilation. The example shows connections; charging rates are not simulated. Manufacturer installation manual

Adapt this charging example

Free, no account needed.

Units

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. V1.1), checked 2026-11-26. Manufacturer documentation →

Which BLUETTI Charger 1 is this?

This is the 560 W Charger 1 for charging a portable power station from a 12 V or 24 V vehicle. Its adjustable output feeds the station’s solar input. It is different from a charger that connects directly to a bare leisure battery.

How is the BLUETTI Charger 1 wired?

IN + and IN − take the vehicle supply through the specified input protection; OUT + and OUT − represent the MC4 charging output. Retain the supplied 60 A breaker and 6 AWG harness described in the V1.1 manual.

The example joins that output to an AC180 using its MC4-to-DC7909 solar cable. The AC180’s 12–60 V, 10 A and 500 W input limits still apply. Its 12 V output socket cannot receive charge. See the AC180 manual.

What should I bear in mind with the BLUETTI Charger 1?

Set the output for the receiving station before connecting it.

  • Voltage range: the V1.1 manual permits 15–56 V from a 12 V vehicle, or 27–56 V from a 24 V vehicle. Output is limited to 10 A; the station may accept less.
  • Installation: IP20 requires a dry, ventilated location. The example preserves the supplied cable interfaces; it does not simulate station charging rates or battery taper. Follow the Charger 1 manual.

What do owners and installers say about the BLUETTI Charger 1?

The practical comparison is simplicity versus additional charging sources. In a Charger 1 versus Charger 2 discussion, the questioner values Charger 1’s compact size; owners of both prefer Charger 2 for simultaneous solar and alternator charging. Those preferences do not establish compatibility with every station.

What belongs around the BLUETTI Charger 1?

Use the AC180 example above to plan the vehicle cable route. Compare Charger 2’s extra ports and explore campervan wiring examples. The wire-size tool helps with ordinary DC extensions; it does not replace BLUETTI’s supplied harness specification.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

CHARGER 1 charges a power station through its solar input from a 12/24 V vehicle. Up to 560 W and 10 A; receiver limits apply. Connection model only; charging rates are not simulated.

Vehicle systems
12 / 24 V
Output ceiling
560 W · 10 A
Output from 12 V vehicle
15–56 V adjustable
Output from 24 V vehicle
27–56 V adjustable
Supplied input breaker
60 A
Example AC180 input limit
500 W · 10 A · 12–60 V

Terminal map

IN +/− connect to the protected vehicle supply. OUT +/− represent the MC4 charging output. Connect to the station’s charging input, not its 12 V output. Cable pairs are schematic interfaces, not connector pinouts.

IN +

positive · input

—

IN −

negative · input

—

OUT +

positive · output

10 A

OUT −

negative · output

10 A

A dash means a current rating is not specified here.

Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Connection overview. This diagram explains the connection arrangement; it does not calculate cable sizes or protection for the installation. Follow the manufacturer’s complete wiring and protection instructions.

Read how the sizing works

Next step

Plan your installation with Charger 1.

Open the connection overview as a new project, or add this component to a diagram you already have.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.